Cross-calibration Of Liquid And Solid QCT Calibration Standards: Corrections To The UCSF Normative Data

K. Faulkner, C. Glüer, S. Grampp, H. Genant
Published 2005 · Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
Quantitative computed tomography (QCT) has been shown to be a precise and sensitive method for evaluating spinal bone mineral density (BMD) and skeletal response to aging and therapy. Precise and accurate determination of BMD using QCT requires a calibration standard to compensate for and reduce the effects of beam-hardening artifacts and scanner drift. The first standards were based on dipotassium hydrogen phosphate (K2HPO4) solutions. Recently, several manufacturers have developed stable solid calibration standards based on calcium hydroxyapatite (CHA) in water-equivalent plastic. Due to differences in attenuating properties of the liquid and solid standards, the calibrated BMD values obtained with each system do not agree. In order to compare and interpret the results obtained on both systems, cross-calibration measurements were performed in phantoms and patients using the University of California San Francisco (UCSF) liquid standard and the Image Analysis (IA) solid standard on the UCSF GE 9800 CT scanner. From the phantom measurements, a highly linear relationship was found between the liquid- and solid-calibrated BMD values. No influence on the cross-calibration due to simulated variations in body size or vertebral fat content was seen, though a significant difference in the cross-calibration was observed between scans acquired at 80 and 140 kVp. From the patient measurements, a linear relationship between the liquid (UCSF) and solid (IA) calibrated values was derived for GE 9800 CT scanners at 80 kVp (IA=[1.15×UCSF]-7.32). The UCSF normative database for women and men obtained with the liquid standard was corrected for use with the solid standard. Proper procedures for cross-calibrating QCT measurements and the appropriate uses of normative data are discussed.
This paper references
10.1097/00004728-198008000-00018
Precise measurement of vertebral mineral content using computed tomography.
C. Cann (1980)
10.1002/JBMR.5650040218
Models of spinal trabecular bone loss as determined by quantitative computed tomography.
J. Block (1989)
10.1080/09553009014552551
Exposure of the US Population from Diagnostic Medical Radiation
P. Shrimpton (1990)
10.1097/00004728-198308000-00053
Quantitative Computed Tomography of Vertebral Spongiosa: A Sensitive Method for Detecting Early Bone Loss After Oophorectomy
H. Genant (1982)
10.1148/radiology.162.1.3786773
Quantitative CT applications: comparison of current scanners.
C. Cann (1987)
10.1016/0378-5122(90)90021-W
Mild versus definite osteoporosis: comparison of bone densitometry techniques using different statistical models.
A. Heuck (1989)
Spinal bone mineral density by quantitative computed tomography: effect of region of interest, vertebral level, and technique
P Steiger (1990)
10.1007/BF01880447
Localization of regional forearm bone loss from high resolution computed tomographic images
P. Rüegsegger (2005)
10.1016/8756-3282(85)90399-0
Quantitative computed tomography for prediction of vertebral fracture risk.
C. Cann (1985)
Solid versus liquid calibration standards for quantitative CT, Radiology 1991;181:206p
MM Goodsitt (1991)
10.2214/ajr.157.6.1950872
Noninvasive measurements of bone mass, structure, and strength: current methods and experimental techniques.
K. Faulkner (1991)
10.1097/00004424-197711000-00015
Quantitative bone mineral analysis using dual energy computed tomography.
H. Genant (1977)
Cross-calibration phantom for spinal bone mineral measurements with quantitative CT and DXA
W Kalender (1992)
Solid versus liquid calibration standards for quantitative CT
MM Goodsitt (1991)
The relationship of peripheral to axial bone density.
P. Schneider (1988)
10.1118/1.596013
A new calibration phantom for quantitative computed tomography.
W. Kalender (1987)
Effect of calibration phantom placement on long-term QCT precision
K Faulkner (1990)
Quantitative CT applications : comparison of newer CT scanners
CE Cann (1987)



This paper is referenced by
10.4081/EJTM.2011.1801
3D Modelling and monitoring of denervated muscle under Functional Electrical Stimulation treatment and associated bone structural changes
Paolo Gargiulo (2011)
10.1002/jor.23417
Agreement and precision of periprosthetic bone density measurements in micro‐CT, single and dual energy CT
B. Mussmann (2017)
10.1016/j.clinbiomech.2018.06.012
Patient‐specific finite element analysis of femurs with cemented hip implants
Y. Katz (2018)
10.1016/j.medengphy.2012.08.022
An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.
Sebastian Eberle (2013)
10.1080/10255842.2017.1380799
Identification of the critical level of implantation of an osseointegrated prosthesis for above-knee amputees
Elder Michael Andrango Castro (2017)
10.1186/s40634-016-0072-2
Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature
N. Knowles (2016)
10.4142/jvs.2015.16.4.531
Quantitative CT assessment of bone mineral density in dogs with hyperadrenocorticism
D. Lee (2015)
10.1007/s11547-012-0881-z
Quality assurance of imaging techniques used in the clinical management of osteoporosis
Giuseppe Guglielmi (2012)
10.1007/s10439-020-02483-3
Population-Based Bone Strain During Physical Activity: A Novel Method Demonstrated for the Human Femur
Hamed Ziaeipoor (2020)
A 3D radiological study of age-related quantitative and morphological differences in the human femur: clinical and anthropological applications
J. Hislop-Jambrich (2010)
PERFORMANCE EVALUATION OF MATERIAL DECOMPOSITION USING RAPID KVP-SWITCHING DUAL-ENERGY CT FOR ASSESSING BONE MINERAL DENSITY
J. M. Wait (2014)
10.1016/j.bone.2020.115321
Hip load capacity and yield load in men and women of all ages.
Joyce H. Keyak (2020)
10.1115/1.4040122
Methods for Post Hoc Quantitative Computed Tomography Bone Density Calibration: Phantom-Only and Regression.
Jacob M. Reeves (2018)
10.3233/BME-151545
Development of phantom for quantitative analyses of human dentin mineral density.
Sachiko Hayashi-Sakai (2015)
10.1016/j.medengphy.2014.06.010
Inter-scanner differences in in vivo QCT measurements of the density and strength of the proximal femur remain after correction with anthropomorphic standardization phantoms.
R. D. Carpenter (2014)
10.1016/j.jbiomech.2020.109599
New insights on the proximal femur biomechanics using Digital Image Correlation.
Y. Katz (2020)
10.1007/s00198-015-3404-7
Left–right differences in the proximal femur’s strength of post-menopausal women: a multicentric finite element study
F. Taddei (2015)
10.1002/jbmr.2241
Fracture risk predictions based on statistical shape and density modeling of the proximal femur.
T. Bredbenner (2014)
10.1007/978-1-59745-459-9_2
Bone Mineral Assessment of the Axial Skeleton: Technical Aspects
Thomas F. Lang (2010)
10.1007/978-88-470-1357-5_40
QTC e pQCT
Giuseppe Guglielmi (2009)
Mechanical testing and modelling of a bone-implant construct
Caroline A. Grant (2012)
10.1002/jmri.23749
Measuring bone mineral density with fat-water MRI: comparison with computed tomography.
Kai-Yu Ho (2013)
10.1359/JBMR.050510
New QCT analysis approach shows the importance of fall orientation on femoral neck strength.
R. D. Carpenter (2005)
10.1007/BF00957107
Current methods and advances in bone densitometry
Giuseppe Guglielmi (2004)
10.1371/journal.pone.0232685
Improved residual fat malabsorption and growth in children with cystic fibrosis treated with a novel oral structured lipid supplement: A randomized controlled trial
Virginia A. Stallings (2020)
10.1016/j.clinimag.2015.09.016
Application of quantitative computed tomography for assessment of trabecular bone mineral density, microarchitecture and mechanical property.
Song Mao (2016)
10.1007/BF01626534
Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro
J. W. Kuiper (2005)
10.1016/j.jocd.2019.02.005
Liquid Calibration Phantoms in Ultra-Low-Dose QCT for the Assessment of Bone Mineral Density.
Malakeh Malekzadeh (2019)
10.1016/B978-0-12-381978-9.10050-2
High-Resolution Imaging Techniques for Bone Quality Assessment
A. Burghardt (2011)
10.1016/B978-0-12-415853-5.00066-2
Clinical Use of Bone Densitometry
Sydney Lou Bonnick (2013)
10.1007/s00261-017-1124-5
Osteoporosis, obesity, and sarcopenia on abdominal CT: a review of epidemiology, diagnostic criteria, and management strategies for the reporting radiologist
Timothy Eanna Murray (2017)
10.1016/B978-012370544-0.50064-1
CHAPTER 62 – Clinical Use of Bone Densitometry
K. Faulkner (2008)
See more
Semantic Scholar Logo Some data provided by SemanticScholar