Primary Stability Of Anterior Lumbar Stabilization: Interdependence Of Implant Type And Endplate Retention Or Removal

C. Flamme, Nadine von der Heide, C. Heymann, C. Hurschler
Published 2005 · Medicine

Save to my Library
Download PDF
Analyze on Scholarcy Visualize in Litmaps
Share
Reduce the time it takes to create your bibliography by a factor of 10 by using the world’s favourite reference manager
Time to take this seriously.
Get Citationsy
This is a comparative in vitro biomechanical study of the primary stability of an anterior lumbar interbody stabilization. The objective was to compare the stability of a interbody stabilizing titanium cage with and without the retention of the bordering vertebral endplates, as well as to compare the titanium cage with a tricalcium phosphate block when the endplates are removed. An adequate blood supply is critical for interbody fusion, which suggests surgical treatment of the bordering endplates. On the other hand, primary stability is improved by the retention of the endplates. Furthermore, bone substitute materials are finding more frequent use due to complications associated with autologous bone grafts. Ten bovine lumbar spine motion segments (average age 6 months) were investigated. Pure bending loadings as well as eccentric axial compression loadings were applied. A titanium cage and tricalcium phosphate block, were tested in conjunction with an anterior augmentation (MACS). Range of motion, neutral zone (NZ) and bending stiffness were measured under pure bending to 10 Nm, and bending stiffness under axial loads of up to 1500 N. Range of motion of both implants in flexion-extension was significantly smaller than physiologic (cage without endplates 4.3°, cage with 2.8°, block without 3.4°, and physiologic 6.6°, all p<0.001). The cage with endplates and the block without endplates were both significantly stiffer than physiologic in all directions except left lateral bending. The block without endplates and the cage with endplates were both stiffer than the cage without endplates. The results suggest that the use of the bone substitute block provides better stability than the cage when the endplates are removed.
This paper references
10.1111/j.1651-2227.1964.tb05158.x
Statistical Methods
G. W. Snedecor (1964)
10.1111/J.1744-6198.1973.TB00531.X
A conceptual framework to guide nursing curriculum.
E. C. Hodgman (1973)
Clinical Biomechanics of the Spine
A. White (1978)
10.2307/2987141
Statistical methods
G. W. Snedecor (1980)
10.1177/016059768100500308
“Model”
S. Papson (1981)
10.1097/00003086-198311000-00019
Posterior lumbar interbody fusion.
P. Lin (1983)
10.1002/JOR.1100030305
Biomechanical time‐tolerance of fresh cadaveric human spine specimens
M. Panjabi (1985)
10.1002/JOR.1100040306
An anatomical comparison of the human and bovine thoracolumbar spine
P. Cotterill (1986)
10.1097/00007632-198810000-00013
Biomechanical Evaluation of Spinal Fixation Devices: I. A Conceptual Framework
M. Panjabi (1988)
10.1097/00006123-198907000-00007
Anterior cervical discectomy with hydroxylapatite fusion.
H. Senter (1989)
Anterior cervical discotomy with hydroxylapatite fusion
GW Snedecor (1989)
Physical properties and functional biomechanics of the spine
AA White (1990)
Physical properties and functional biomechanics of the spine. In: White AA, Panjabi MM (eds) Clinical biomechanics of the spine
M Panjabi (1990)
[Three-dimensional testing of the stability of spinal implants].
M. Panjabi (1991)
10.1002/JOR.1100090318
An anatomic basis for spinal instability: A porcine trauma model
T. Oxland (1991)
10.1097/00007632-199106001-00024
Two-Point Fixation of the Lumbar Spine: Differential Stability in Rotation
T. Zdeblick (1991)
10.1097/00002517-199212000-00002
The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis.
M. Panjabi (1992)
10.1097/00002517-199302000-00004
Spinal instrumentation for metastatic disease: in vitro biomechanical analysis.
J. Heller (1993)
10.1097/00007632-199303010-00016
Anterior spinal fixators. A biomechanical in vitro study.
T. Zdeblick (1993)
10.1097/00007632-199306150-00010
Mechanics of interbody spinal fusion. Analysis of critical bone graft area.
R. F. Closkey (1993)
10.1097/00007632-199411001-00006
Fusion Rate and Biomechanical Stiffness of Hydroxylapatite Versus Autogenous Bone Grafts for Anterior Discectomy: An In Vivo Animal Study
F. Pintar (1994)
10.1097/00007632-199407000-00002
Interbody Lumbar Fusion Using a Carbon Fiber Cage Implant Versus Allograft Bone: An Investigational Study in the Spanish Goat
J. Brantigan (1994)
10.1097/00003086-199403000-00006
Anterior lumbar fusion options. Technique and graft materials.
Kozak Ja (1994)
10.1097/00007632-199408150-00011
In Vivo Evaluation of Anterior Cervical Fusions with Hydroxylapatite Graft Material
S. Cook (1994)
10.1097/00007632-199511001-00007
Biomechanical Properties of Threaded Inserts for Lumbar Interbody Spinal Fusion
A. Tencer (1995)
10.1097/00007632-199505000-00012
Iliac crest bone graft harvest donor site morbidity. A statistical evaluation.
Banwart Jc (1995)
10.1097/00007632-199509150-00003
Biomechanical Evaluation of Anterior Thoracolumbar Spinal Instrumentation
H. An (1995)
Iliac Crest Bone Graft Harvest Donor Site Morbidity: A Statistical Evaluation
J. C. Banwart (1995)
10.1097/00007632-199510001-00005
Evaluation of Porous Biphasic Calcium Phosphate Ceramics for Anterior Cervical Interbody Fusion in a Caprine Model
J. Toth (1995)
10.1097/00007632-199612010-00003
Ceramic Anterior Spinal Fusion: Biologic and Biomechanical Comparison in a Canine Model
S. Emery (1996)
10.1097/00007632-199609150-00015
The Effects of Internal Fixation on Calcium Carbonate: Ceramic Anterior Spinal Fusion in Dogs
D. A. Fuller (1996)
10.1097/00007632-199605010-00007
Biomechanical Analysis of Thoracolumbar Interbody Constructs: How Important Is the Endplate?
J. Hollowell (1996)
10.1097/00007632-199701010-00005
Posterior Lumbar Interbody Fusion: A Biomechanical Comparison, Including a New Threaded Cage
D. Brodke (1997)
10.1097/00007632-199701150-00008
Biomechanical Analysis of Multilevel Fixation Methods in the Lumbar Spine
P. Glazer (1997)
10.1097/00007632-199710010-00005
Analysis of Harvest Morbidity and Radiographic Outcome Using Autograft for Anterior Cervical Fusion
C. L. Schnee (1997)
10.1002/(SICI)1097-0185(199704)247:4<542::AID-AR13>3.0.CO;2-P
Anatomy of the sheep spine and its comparison to the human spine
H. Wilke (1997)
10.1007/PL00003483
Biological reactions to calciumphosphate ceramic implants.
J. Rueger (1998)
10.1007/PL00003477
Bone substitutes and bone formation
H. Stützle (1998)
10.1007/S001320050208
[Integration properties of bone substitute materials. Experimental studies on animals].
K. Günther (1998)
10.1007/PL00003481
Bone replacement materials – state of the art and the way ahead
J. Rueger (1998)
10.1097/00007632-199803010-00006
Stability Potential of Spinal Instrumentations in Tumor Vertebral Body Replacement Surgery
M. Vahldiek (1998)
10.1007/S001320050203
[Bone substitution materials].
H. Refior (1998)
10.1016/S0142-9612(97)00180-4
Macroporous biphasic calcium phosphate ceramics: influence of macropore diameter and macroporosity percentage on bone ingrowth.
O. Gauthier (1998)
KNOCHENERSATZMITTEL: HEUTIGER STAND UND AUSBLICK
J. Rüger (1998)
BIOLOGISCHE REAKTIONEN AUF KALZIUMPHOSPHATKERAMIK-IMPLANTATIONEN : TIEREXPERIMENTELLE ERGEBNISSE
J. Rüger (1998)
10.1097/00007632-199803010-00020
Spine update lumbar interbody cages.
B. Weiner (1998)
10.1007/PL00003478
Xenogenic deproteinized bone substitute Pyrost. Experimental basics and 13 years of clinical experience in more than 1000 cases
H. Mittelmeier (1998)
10.1007/s005860050045
Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants
H. Wilke (1998)
10.1007/PL00003476
Osteointegration of different bone substitute materials in an experimental model
K. Günther (1998)
MINERALISCHES, SPONGIOSES KNOCHENERSATZMATERIAL PYROST: EXPERIMENTELLE GRUNDLAGEN UND 13 JAHRE KLINISCHE ERFAHRUNG BEI UBER 1000 FALLEN
H. Mittelmeier (1998)
10.1097/00007632-199801150-00003
Experimental Posterolateral Lumbar Spinal Fusion With a Demineralized Bone Matrix Gel
M. Morone (1998)
[Bone substitution materials. Current status and prospects].
J. Rüger (1998)
10.1007/S001320050206
[Biologic reactions to calcium phosphate ceramic implantations. Results of animal experiments].
J. Rueger (1998)
10.1007/S001320050209
Knochenneubildung durch Knochenersatzmaterialien
H. Stützle (1998)
update lumbar interbody cages
BK Weiner (1998)
10.1097/00007632-199911010-00006
Stability analysis of an enhanced load sharing posterior fixation device and its equivalent conventional device in a calf spine model.
J. Scifert (1999)
10.1097/00007632-199906150-00002
Posterolateral Lumbar Intertransverse Process Spine Arthrodesis With Recombinant Human Bone Morphogenetic Protein 2/Hydroxyapatite‐Tricalcium Phosphate After Laminectomy in the Nonhuman Primate
S. Boden (1999)
10.1097/00007632-199908150-00003
The stability of reconstruction methods after thoracolumbar total spondylectomy. An in vitro investigation.
I. Oda (1999)
10.1097/00007632-199907010-00005
Anterior interbody fusion of the cervical spine with coralline hydroxyapatite.
J. Thalgott (1999)
10.3171/SPI.2000.93.2.0259
In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices.
M. Kanayama (2000)
10.1007/PL00010028
Biomechanics of stand-alone cages and cages in combination with posterior fixation: a literature review
T. Oxland (2000)
10.1055/S-2000-15596
[Initial instability of different cages for fusion of the cervical spine].
P. Eysel (2000)
10.1007/s001320050489
Biomechanische Korrekturprinzipien ventraler und dorsaler Instrumentationen bei Skoliosen
P. Eysel (2000)
10.1007/s005860000223
The influence of cancellous bone density on load sharing in human lumbar spine: a comparison between an intact and a surgically altered motion segment
T. Pitzen (2000)
10.1007/s001320050489
Biomechanical principles of anterior and posterior instrumentation in scoliosis
P. Eysel (2000)
10.1097/00007632-200011010-00007
Anterior Vertebral Screw Strain With and Without Solid Interspace Support
D. Spiegel (2000)
10.1097/00002517-200004000-00010
Biomechanical effect of anterior grafting devices on the rotational stability of spinal constructs.
S. W. Lee (2000)
10.1007/S001130170041
[Biomechanical stability with a new artificial vertebral body implant. 3-dimensional movement analysis of instrumented human vertebral segments].
C. Knop (2001)
10.1007/s001130050684
Vergleichende biomechanische Kompressionsversuche mit einem neuen Wirbelkörperersatzimplantat
C. Knop (2001)
10.1007/S001130170071
[Value of human recombinant osteogenetic proteins as bone replacement materials in lumbar spondylodesis. Results of an animal experiment study].
O. Paar (2001)
10.1007/s001130170071
Wertigkeit von rekombinantem humanem osteogenetischem Protein als Knochenersatzmaterial bei der lumbalen Spondylodese Ergebnisse einer tierexperimentellen Untersuchung
O. Paar (2001)
10.1007/s00132-001-0296-3
In-vitro-Stabilitätsuntersuchung eines neuartigen Implantatsystems für den minimal-invasiven transforaminalen Zugang
S. Schneid (2001)
10.1097/00007632-200104150-00012
Mapping the Structural Properties of the Lumbosacral Vertebral Endplates
J. P. Grant (2001)
10.1097/00007632-200104150-00021
Effect of Endplate Conditions and Bone Mineral Density on the Compressive Strength of the Graft–Endplate Interface in Anterior Cervical Spine Fusion
T. Lim (2001)
[Comparative biomechanical compression trials with a new vertebral prosthetic implant].
C. Knop (2001)
10.1007/s00132-001-0276-7
MACS-TL-twin-screw
M. Schultheiss (2001)
10.1007/s00132-001-0289-2
Einfluss von Design und Implantationstechnik auf das Risiko der progredienten Sinterung verschiedener HWS-Cages
S. Fürderer (2001)
10.1007/s00132-001-0294-5
Vergleich unterschiedlicher Wirbelkörperersatzsysteme hinsichtlich Migration und Primärstabilität bei dorsoventraler Spondylodese nach Korporektomie mit und ohne Laminektomie
M. Morlock (2001)
10.1007/s00132-001-0282-9
MACS-TL®-Polyaxialscrew XL
M. Schultheiss (2001)
10.1007/s00132-001-0287-4
Mechanische Untersuchungen von lumbalen interkorporellen Fusionsimplantaten
R. Bader (2001)
10.1007/s00132-001-0285-6
Entwicklung und klinischer Einsatz einer thorakoskopisch implantierbaren Rahmenplatte zur Behandlung thorakolumbaler Frakturen und Instabilitäten
R. Beisse (2001)
10.1097/00007632-200104150-00022
An Experimental Study on the Interface Strength Between Titanium Mesh Cage and Vertebra in Reference to Vertebral Bone Mineral Density
K. Hasegawa (2001)
10.1007/s001130050718
Madreporische Hydroxylapatitgranulate zur Füllung ossärer Defekte
C. Müller-Mai (2001)
10.1007/s00132-001-0284-7
Mechanische Testung der Implantateigenschaften eines thorakoskopisch implantierbaren ventralen Wirbelsäulenstabilisierungssystems
T. Grupp (2001)
10.1007/s001130170041
Biomechanische Stabilität mit einem neuen Wirbelkörperersatzimplantat Dreidimensionale Bewegungsanalyse an instrumentierten humanen Wirbelsäulenpräparaten
C. Knop (2001)
10.1007/s00132-001-0290-9
Dislokationstendenz, stabilisierende Wirkung und Einbruchtendenz unterschiedlicher LWS-Cages im In-vitro-Experiment
A. Kettler (2001)
10.1007/S00132-001-0276-7
[MAC-TL twin screw. A new thoracoscopic implantable stabilization system for treatment of vertebral fractures--implant design, implantation technique and in vitro testing].
M. Schultheiss (2002)
Grading- er R (2002) Mechanische untersuchun- gen von lumbalen interkorporellen Fusionsimplantaten
RJ Bader (2002)
MACS-TL-Poly- axialscrew XL
M Schultheiss (2002)
10.1007/BF01358746
Load-displacement properties of the thoracolumbar calf spine: Experimental results and comparison to known human data
H. Wilke (2005)
10.1007/BF02428314
Anterior lumbar fusion using a hybrid interbody graft
D. Holte (2006)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar