Online citations, reference lists, and bibliographies.

Experimental Studies And Numerical Analysis Of The Inflation And Interaction Of Vascular Balloon Catheter-Stent Systems

Dimitrios E. Kiousis, Alexander R. Wulff, Gerhard A. Holzapfel
Published 2008 · Medicine, Chemistry
Cite This
Download PDF
Analyze on Scholarcy
Share
Balloon angioplasty with stenting is a well-established interventional procedure to treat stenotic arteries. Despite recent advances such as drug eluting stents, clinical studies suggest that stent design is linked to vascular injury. Additionally, dilation of the medical devices may trigger pathological responses such as growth and migration of vascular smooth cells, and may be a potent stimulus for neointimal hyperplasia. The purpose of this study is to experimentally investigate the mechanical characteristics of the transient expansion of six commercially available balloon-expandable stent systems, and to develop a robust finite element model based on the obtained experimental results. To reproduce the inflation of stent systems as in clinical practice, a pneumatic–hydraulic experimental setup is built, able to record loads and deformations. Characteristic pressure–diameter diagrams for the balloon-expandable stents and the detached balloons are experimentally obtained. Additionally, typical measures such as the burst opening pressure, the maximum dog-boning and foreshortening, and the elastic recoil are determined. The adopted constitutive models account for elastoplastic deformation of the stent, and for the nonlinear and anisotropic behavior of the balloon. The employed contact algorithm, based on a C2-continuous surface parametrization, efficiently simulates the interaction of the balloon and stent. The computational model is able to successfully capture the experimentally observed deformation mechanisms. Overall, the numerical results are in satisfactory agreement with experimental data.
This paper references
10.1007/978-90-481-2331-5
Nonlinear Solid Mechanics
Adnan Ibrahimbegovic (2009)
10.1161/01.CIR.99.1.44
Pathology of acute and chronic coronary stenting in humans.
Andrew Farb (1999)
10.1002/1097-0207(20010210)50:4<953::AID-NME64>3.0.CO;2-P
On the modelling of smooth contact surfaces using cubic splines
N. El-Abbasi (2001)
10.1016/S0002-9149(98)00189-1
Pathobiologic responses to stenting.
Elazer R. Edelman (1998)
10.1016/S0924-0136(03)00435-7
Finite element simulation of stent and balloon interaction
S. N. David Chua (2003)
10.1080/10255840601086234
Finite element comparison of performance related characteristics of balloon expandable stents
Eric W. Donnelly (2007)
10.1002/(SICI)1521-4052(199912)30:12<876::AID-MAWE876>3.0.CO;2-O
Measurement and Numerical Simulation of the Dilatation Behaviour of Coronary Stents
Heinz Brauer (1999)
10.1056/NEJMoa035071
Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery.
Jeffrey W. Moses (2003)
Clinical evidence on polymer-based sirolimus and paclitaxel eluting stents.
Raisuke Iijima (2006)
10.1002/nme.776
Cn continuous modelling of smooth contact surfaces using NURBS and application to 2D problems
Michael Stadler (2003)
10.1002/(SICI)1522-726X(200005)50:1<120::AID-CCD26>3.0.CO;2-T
Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion.
John A Ormiston (2000)
10.1016/j.jbiomech.2004.11.003
Analysis of the transient expansion behavior and design optimization of coronary stents by finite element method.
Wei-Qiang Wang (2006)
10.1016/S0735-1097(97)00450-6
In-stent restenosis: contributions of inflammatory responses and arterial injury to neointimal hyperplasia.
Ran Kornowski (1998)
10.1007/s00392-002-1317-x
Influence of stent design and deployment technique on neointima formation and vascular remodeling
Andreas König (2002)
10.1016/j.jbiomech.2004.07.022
Cardiovascular stent design and vessel stresses: a finite element analysis.
Caitríona Lally (2005)
10.1016/j.finel.2007.01.001
A general finite element analysis method for balloon expandable stents based on repeated unit cell (RUC) model
Zihui Xia (2007)
10.4028/www.scientific.net/KEM.288-289.571
Finite Element Analysis of a Stent Implantation in a Stenosed Artery
Dong-ke Liang (2005)
10.1088/0967-3334/22/2/303
Assessment of computer-controlled inflation/deflation for determining the properties of PTCA balloon catheters with pressure-volume curves.
Tom Olbrich (2001)
10.1161/CIRCULATIONAHA.107.187998
Heart disease and stroke statistics--2007 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee.
Wayne D. Rosamond (2007)
10.1016/S0002-9149(99)00053-3
Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique.
Rainer Hoffmann (1999)
10.1016/j.media.2007.09.001
A methodology to study the morphologic changes in lesions during in vitro angioplasty using MRI and image processing
M. Auer (2008)
10.1056/NEJM199408253310801
A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.
P. W. Serruys (1994)
10.1007/978-3-642-59223-2
The NURBS Book
Les A. Piegl (1997)
10.1002/nme.1001
Subdivision schemes for smooth contact surfaces of arbitrary mesh topology in 3D
Michael Stadler (2004)
10.3233/thc-2006-144-506
Finite element analysis and stent design: Reduction of dogboning.
Matthieu De Beule (2006)
10.1016/j.commatsci.2004.05.001
Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modelling
J. Patrick McGarry (2004)
10.4028/www.scientific.net/KEM.340-341.847
Plasticity in the Mechanical Behaviour of Cardiovascular Stents during Stent Preparation (Crimping) and Placement (Expansion)
Matthieu De Beule (2007)
10.1023/A:1010835316564
A New Constitutive Framework for Arterial Wall Mechanics and a Comparative Study of Material Models
Gerhard A. Holzapfel (2000)
European cardiovascular disease statistics
Steve Allender (2008)
10.1002/(SICI)1522-726X(199903)46:3<380::AID-CCD27>3.0.CO;2-J
Radial force of coronary stents: a comparative analysis.
Régis Rieu (1999)
10.1016/S0021-9290(02)00033-7
Mechanical behavior of coronary stents investigated through the finite element method.
Francesco Migliavacca (2002)
10.1067/mva.2002.122878
Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis.
Timothy M Sullivan (2002)
10.1002/(SICI)1522-726X(200005)50:1<112::AID-CCD25>3.0.CO;2-X
Elastic recoil of coronary stents: a comparative analysis.
Paul Barragan (2000)
10.1016/S0168-874X(00)00029-9
A framework for development of surface smoothing procedures in large deformation frictional contact analysis
Vineet Padmanabhan (2001)
10.1016/S0735-1097(99)00254-5
A randomized trial of elective stenting after balloon recanalization of chronic total occlusions.
M. Höher (1999)
10.1016/S1051-0443(07)61620-0
Physical properties of endovascular stents: an experimental comparison.
Stephan H. Duda (2000)
10.1016/j.medengphy.2004.08.012
A predictive study of the mechanical behaviour of coronary stents by computer modelling.
Francesco Migliavacca (2005)
10.3109/07853899409147335
Restenosis after vascular reconstruction.
Seppo T Nikkari (1994)
10.1161/01.CIR.0000127110.49192.72
One-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent: The TAXUS-IV Trial
Gregg W Stone (2004)
10.1007/s10439-007-9357-z
A Numerical Model to Study the Interaction of Vascular Stents with Human Atherosclerotic Lesions
Dimitrios E. Kiousis (2007)
10.1016/S0140-6736(03)12275-1
Drug-eluting stents in vascular intervention
Rossella Fattori (2003)
10.1115/1.1835362
Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.
Gerhard A. Holzapfel (2005)
10.1002/NME.2277
Smooth contact strategies with emphasis on the modeling of balloon angioplasty with stenting
Dimitrios E. Kiousis (2008)
10.1002/(SICI)1097-0207(19980315)41:5<781::AID-NME308>3.0.CO;2-9
Finite rotations in dynamics of beams and implicit time-stepping schemes
Adnan Ibrahimbegovic (1998)
10.1161/01.CIR.94.6.1247
Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study.
Rainer Hoffmann (1996)
10.1016/0735-1097(92)90098-8
Angiographic and clinical outcome of intracoronary stenting: immediate and long-term results from a large single-center experience.
Joseph P. Carrozza (1992)
10.1016/S0021-9290(00)00098-1
Mechanical behaviour modelling of balloon-expandable stents.
Claude Dumoulin (2000)
10.1023/A:1020843529530
Nonlinear Solid Mechanics: A Continuum Approach for Engineering Science
Gerhard A. Holzapfel (2000)
Heart Association Statistics Committee and Stroke Statistics Subcommittee Heart Disease and Stroke Statistics—2006 Update: A Report From the American
Matthew D. Wilson (2009)
10.1016/S1522-1865(02)00137-3
Topical application of beta-radiation to reduce intimal hyperplasia after carotid artery balloon injury in rabbit. A possible application for brachytherapy in vascular surgery.
David Rosenthal (2002)
10.1016/S0021-9290(01)00026-4
Mechanical properties of coronary stents determined by using finite element analysis.
Frederique Etave (2001)
10.1016/j.patbio.2004.03.013
The influence of physical stent parameters upon restenosis.
Allison C. Morton (2004)
10.1161/01.CIR.91.12.2995
Endovascular stent design dictates experimental restenosis and thrombosis.
C Rogers (1995)
10.1016/S0735-1097(02)02704-3
Sirolimus-eluting stent for treatment of complex in-stent restenosis: the first clinical experience.
Muzaffer Değertekin (2003)
Stent design: implications for restenosis.
McLean Dr (2002)
10.1161/CIRCULATIONAHA.106.179918
Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee.
Wayne D. Rosamond (2008)



This paper is referenced by
10.1002/NME.4342
Finite element modeling of cerebral angioplasty using a structural multi‐mechanism anisotropic damage model
DaLong Li (2012)
10.1142/S1758825110000718
EFFECTS OF BALLOON LENGTH AND COMPLIANCE ON VASCULAR STENT EXPANSION
Fangsen Cui (2010)
Comparative examination of the functional properties of coronary stents
Dóra Károly (2014)
10.21427/D7G31Z
Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents.
David D Martin (2013)
10.3233/JAE-2012-1501
Influence of work hardening on the performance of stents
Ming Dao Wang (2012)
10.1002/9781119176817.ECM2041
Computational Biomechanics of Soft Biological Tissues: Arterial Walls, Hearts Walls, and Ligaments
Gerhard A. Holzapfel (2017)
10.4018/jcmam.2011010101
Relevance of Mesh Dimension Optimization, Geometry Simplification and Discretization Accuracy in the Study of Mechanical Behaviour of Bare Metal Stents
Mariacristina Gagliardi (2011)
10.1002/ZAMM.201700360
Non‐affine fiber kinematics in arterial mechanics: a continuum micromechanical investigation
Claire Morin (2018)
10.1371/journal.pone.0224026
Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning
Lisa Wiesent (2019)
Biomechanical Modeling of Atherosclerotic Plaques for Risk Assessment
Ali C Akyildiz (2013)
10.1016/j.jbiomech.2010.03.050
Simulation of a balloon expandable stent in a realistic coronary artery-Determination of the optimum modelling strategy.
Houman Zahedmanesh (2010)
Finite element and mechanobiological modelling of vascular devices
Houman Zahedmanesh (2011)
Study of Non-Linear Deformation of Peripheral Stent Mechanics Using Com- putational Approach
Hua Yang (2016)
10.1016/J.JMST.2017.10.002
Effect of cold deformation on corrosion fatigue behavior of nickel-free high nitrogen austenitic stainless steel for coronary stent application
Jun Li (2017)
10.1186/s12938-016-0268-9
Multi-objective optimization of coronary stent using Kriging surrogate model
Hongxia Li (2016)
10.1016/j.jbiomech.2014.01.039
Analyses and design of expansion mechanisms of balloon expandable vascular stents.
Graeham R. Douglas (2014)
10.1016/j.medengphy.2010.07.002
Mechanical design of an intracranial stent for treating cerebral aneurysms.
Yasuhiro Shobayashi (2010)
10.1016/j.jbiomech.2015.03.024
A finite element strategy to investigate the free expansion behaviour of a biodegradable polymeric stent.
Nic Debusschere (2015)
10.5772/37357
Vascular Stent Design Optimisation Using Numerical Modelling Techniques
Houman Zahedmanesh (2012)
10.1115/1.4040400
Sensitivity of Arterial Hyperelastic Models to Uncertainties in Stress-Free Measurements.
Nir Emuna (2018)
10.1142/S1756973713300025
Structurally Motivated Models of the Arterial Wall Tissue
Hadi Taghizadeh (2013)
10.1155/2018/2648910
FEM Simulation of Subintimal Angioplasty for the Treatment of Chronic Total Occlusions
Andrea Avanzini (2018)
Modeling Active Anisotropic Materials Undergoing Finite Deformations
Yali Li (2017)
10.1002/jbm.b.33100
Modeling and simulation of material degradation in biodegradable wound closure devices.
Linfei Xiong (2014)
10.1007/S11340-012-9620-6
Ex Vivo Coronary Stent Implantation Evaluated with Digital Image Correlation
Lukáš Horný (2012)
10.1142/S0219519417400371
NUMERICAL ANALYSIS OF BALLOON EXPANDABLE STENT DEPLOYMENT INSIDE A PATIENT-SPECIFIC STENOTIC CORONARY ARTERY TO INVESTIGATE THE INSTANT MECHANICAL BEHAVIORS
Chuangye Xu (2017)
10.1002/cnm.2557
Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
David Moral Martín (2013)
10.1007/S00158-013-0926-5
Design optimization of balloon-expandable coronary stent
Hongxia Li (2013)
10.1016/J.MSEB.2011.03.013
Finite element analyses for design evaluation of biodegradable magnesium alloy stents in arterial vessels
Wei Wu (2011)
10.1155/2013/630243
Design Optimization of Coronary Stent Based on Finite Element Models
Hongxia Li (2013)
10.1007/S13239-012-0104-8
A Computational Test-Bed to Assess Coronary Stent Implantation Mechanics Using a Population-Specific Approach
Claire Conway (2012)
10.1016/j.jbiomech.2015.12.013
Multi-objective optimisation of stent dilation strategy in a patient-specific coronary artery via computational and surrogate modelling.
Georgios E. Ragkousis (2016)
See more
Semantic Scholar Logo Some data provided by SemanticScholar