Numerical Modelling Of Femur Fracture And Experimental Validation Using Bone Simulant

M. Marco, E. Giner, R. Larraínzar-Garijo, J. R. Caeiro, M. Miguélez
Published 2017 · Materials Science, Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
Bone fracture pattern prediction is still a challenge and an active field of research. The main goal of this article is to present a combined methodology (experimental and numerical) for femur fracture onset analysis. Experimental work includes the characterization of the mechanical properties and fracture testing on a bone simulant. The numerical work focuses on the development of a model whose material properties are provided by the characterization tests. The fracture location and the early stages of the crack propagation are modelled using the extended finite element method and the model is validated by fracture tests developed in the experimental work. It is shown that the accuracy of the numerical results strongly depends on a proper bone behaviour characterization.
This paper references
Safety factor of the proximal femur during gait : a population - based finite element study
F. Taddei (2014)
10.1016/j.jmbbm.2014.05.006
Numerical modelling of the mechanical behaviour of an osteon with microcracks.
E. Giner (2014)
10.1016/j.jbiomech.2011.05.038
The human proximal femur behaves linearly elastic up to failure under physiological loading conditions.
M. Juszczyk (2011)
10.1016/j.jbiomech.2014.08.024
To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?
E. Schileo (2014)
10.1016/j.jbiomech.2009.06.001
The fracture toughness of cancellous bone.
R. Cook (2009)
10.1016/j.jmbbm.2011.11.013
Experimental and numerical characterisation of the elasto-plastic properties of bovine trabecular bone and a trabecular bone analogue.
N. Kelly (2012)
10.1016/0021-9290(95)00084-4
Mechanical validation of whole bone composite femur models.
L. Cristofolini (1996)
10.1016/j.medengphy.2012.02.012
Biomechanical stress maps of an artificial femur obtained using a new infrared thermography technique validated by strain gages.
S. Shah (2012)
10.1016/j.biomaterials.2009.06.017
Mixed-mode fracture of human cortical bone.
E. Zimmermann (2009)
10.1016/S0021-9290(01)00011-2
Dependence of yield strain of human trabecular bone on anatomic site.
E. Morgan (2001)
10.1016/J.BONE.2007.08.039
Load distribution in the healthy and osteoporotic human proximal femur during a fall to the side.
E. Verhulp (2008)
10.1016/j.jbiomech.2014.10.025
A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures.
T. Basso (2014)
10.1016/J.JBIOMECH.2007.09.009
Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro.
E. Schileo (2008)
Standard Handbook Of Biomedical Engineering And Design
A. Schmid (2016)
10.1016/j.jmbbm.2014.12.006
A review on recent advances in numerical modelling of bone cutting.
M. Marco (2015)
10.1007/s10439-013-0864-9
A Robust 3D Finite Element Simulation of Human Proximal Femur Progressive Fracture Under Stance Load with Experimental Validation
R. Hambli (2013)
10.1016/j.jbiomech.2013.10.033
Specimen-specific modeling of hip fracture pattern and repair.
Azhar A. Ali (2014)
10.1016/j.jbiomech.2011.10.019
Accuracy of finite element predictions in sideways load configurations for the proximal human femur.
L. Grassi (2012)
10.1016/j.jbiomech.2010.03.019
Strain and micromotion in intact and resurfaced composite femurs: experimental and numerical investigations.
B. Pal (2010)
10.5312/wjo.v5.i4.402
Complications of hip fractures: A review.
P. Carpintero (2014)
10.1098/rsta.2010.0046
Mechanical testing of bones: the positive synergy of finite–element models and in vitro experiments
L. Cristofolini (2010)
10.1016/j.jbiomech.2014.08.030
European Society of Biomechanics S.M. Perren Award 2014: Safety factor of the proximal femur during gait: a population-based finite element study.
F. Taddei (2014)
10.1016/J.JBIOMECH.2007.03.015
In vitro replication of spontaneous fractures of the proximal human femur.
L. Cristofolini (2007)
10.1016/j.jmbbm.2012.09.005
Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study.
H. Ebrahimi (2012)
10.1016/j.jbiomech.2009.05.038
Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.
R. Bryan (2009)
10.1016/j.jbiomech.2016.02.032
How accurately can subject-specific finite element models predict strains and strength of human femora? Investigation using full-field measurements.
L. Grassi (2016)
10.1016/S0021-9290(99)00202-X
Relationships between femoral fracture loads for two load configurations.
J. Keyak (2000)
10.1016/j.jmbbm.2013.02.006
Experimental validation of finite element model for proximal composite femur using optical measurements.
L. Grassi (2013)
10.1016/J.ENGFRACMECH.2003.08.003
Modelling bone tissue fracture and healing: a review ☆
M. Doblaré (2004)
10.1007/s10439-009-9887-7
Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia Models
M. Gardner (2009)
10.1016/S0021-9290(03)00257-4
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue.
Harun H. Bayraktar (2004)
10.1016/j.injury.2015.07.021
Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fractures.
Thomas K Schaefer (2015)
The Material Properties of Human Tibia Cortical Bone in Tension and Compression: Implications for the Tibia Index
A. Kemper (2007)
10.1115/1.2798339
A cellular solid criterion for predicting the axial-shear failure properties of bovine trabecular bone.
C. Fenech (1999)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar