Metal ion release from the orthopedic implants is a great concern for the clinicians and patients. Currently, the inductive coupled plasma-mass spectroscopy (ICP-MS) technique is used to detect and estimate the metal ions in the blood or synovial fluid, which is expensive and needs technical assistance. Hence, the aim of the current work is to develop a biosensor based on the electrochemistry to measure the metal release to the body fluids (blood or synovial fluid) from the implants. This will work very similar to a glucometer (by function), as a patient-driven technique, if it is optimized for the blood samples, and for clinical purpose, in case of the synovial fluid estimation. As a proof of concept effort, the present study has two objectives: (1) To study the effectiveness of using a micro-chip biosensor as a diagnostic technique for the early detection of the released metal particles in the synovial fluid solution (study 1), and (2) to investigate the corrosion kinetics of CoCrMo alloy in the presence of metal particles in synovial fluid solution (study 2). A series of tests were done with biosensor prototype with increasing concentration of metal release (particles and ions), which is generated from a hip simulator (study 1). The impedance variation (delta Z) shows a very close correlation with increased amount of metal release (particles and ions) level (study 2). Although the study has several limitations, the initial findings indicate that a biosensor could be developed as a diagnostic tool to detect the metal release (particles and ions) levels.
This paper references
The effects of residual carbon on the determination of chromium in blood and tissue sample using Quadrupole ICP-MS
Jürgen Kunze (2005)
10.1002/jbm.820271210
In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling.
Jeremy L Gilbert (1993)
10.3109/17453674.2012.747055
Metal-on-metal joint bearings and hematopoetic malignancy
P. H. Wagner (2012)
10.11138/ccmbm/2013.10.1.034
The effects on bone cells of metal ions released from orthopaedic implants. A review.
Valerio Sansone (2013)
10.5301/hipint.5000113
Metal Ion Levels and Revision Rates in Metal-On-Metal Hip Resurfacing Arthroplasty: A Comparative Study
Patrick G. Robinson (2014)
10.1002/jat.3100
Toxicity of cobalt-chromium nanoparticles released from a resurfacing hip implant and cobalt ions on primary human lymphocytes in vitro.
Olga M. Posada (2015)
10.1038/srep23111
A wearable biochemical sensor for monitoring alcohol consumption lifestyle through Ethyl glucuronide (EtG) detection in human sweat
Anjan Panneer Selvam (2016)
10.1007/s00402-015-2165-2
Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips
Bart H Bosker (2015)
10.1016/j.bios.2017.03.031
A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms.
Babankumar S. Bansod (2017)
10.1016/j.arth.2016.02.082
Diagnosis and Treatment of Adverse Local Tissue Reactions at the Head-Neck Junction.
H John Cooper (2016)
10.1016/j.esas.2009.11.005
A review of the biologic effects of spine implant debris: Fact from fiction
Nadim James Hallab (2009)
Progressive Cardiomyopathy in a Patient With Elevated Cobalt Ion Levels and Bilateral Metal-on-Metal Hip Arthroplasties.
Brian A Mosier (2016)
10.1016/j.arth.2013.02.009
Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements.
Richard Baker Cook (2013)
10.1002/jor.21526
The influence of Co-Cr and UHMWPE particles on infection persistence: an in vivo study in mice.
Anton H. Hosman (2012)
10.1038/srep14586
Flexible nanoporous tunable electrical double layer biosensors for sweat diagnostics
Rujuta D. Munje (2015)
10.2106/JBJS.C.00949
An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements.
A. Paul Davies (2005)
Diagnosis and treatment of adverse local tissue reactions at the head-neck junction
HJ Cooper (2016)
10.1016/j.actbio.2008.07.032
Presence of corrosion products and hypersensitivity-associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces.
Monika Huber (2009)
10.2106/JBJS.M.00957
Surveillance of Patients with Metal-on-Metal Hip Resurfacing and Total Hip Prostheses: A Prospective Cohort Study to Investigate the Relationship Between Blood Metal Ion Levels and Implant Failure.
Alister J. Hart (2014)
Biosensors: properties, materials and applications
R Comeaux (2009)
10.1007/s10195-016-0391-1
Trunnionosis in total hip arthroplasty: a review
Jaydev B. Mistry (2016)
10.1016/j.arth.2012.07.040
Do ion concentrations after metal-on-metal hip resurfacing increase over time? A prospective study.
Harlan C. Amstutz (2013)
10.1016/S0021-9290(10)70125-1
M-16 A New Tool to Assess Corrosion and Metal Ion Release in Artificial Hip Joints
Yu Yan (2010)
10.1016/J.JOR.2016.10.023
601 metal-on-metal total hip replacements with 36 mm heads a 5 minimum year follow up: Levels of ARMD remain low despite a comprehensive screening program.
Amit Atrey (2017)
10.1016/j.bios.2011.11.055
Nanoporous impedemetric biosensor for detection of trace atrazine from water samples.
Pie Pichetsurnthorn (2012)
10.1038/srep33423
Ultrasensitive and low-volume point-of-care diagnostics on flexible strips – a study with cardiac troponin biomarkers
Nandhinee Radha Shanmugam (2016)
10.1007/s11999-012-2563-5
Wear-Corrosion Synergism in a CoCrMo Hip Bearing Alloy Is Influenced by Proteins
Mathew T. Mathew (2012)
10.1038/s41598-017-02133-0
A new paradigm in sweat based wearable diagnostics biosensors using Room Temperature Ionic Liquids (RTILs)
Rujuta D. Munje (2017)
10.1016/S0736-0266(03)00186-4
Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements.
Nadim James Hallab (2004)



Semantic Scholar Logo Some data provided by SemanticScholar