Validation Of An Automated Method Of Three-dimensional Finite Element Modelling Of Bone.

J. Keyak, M. G. Fourkas, J. M. Meagher, H. Skinner
Published 1993 · Engineering, Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
This study validated an automated method of finite element modelling of bone from CT scan data. After a fresh-frozen cadaveric femur was modelled, strain gauges were attached to the bone at 11 locations and the femur was mechanically tested by applying a load to the femoral head. Linear regression analysis was used to correlate the strains predicted by the model with the experimentally measured strains. The regression results were significant (P < 0.001), indicating that the strain calculated by the FE model is a valid predictor of the measured strain. Verification of the surface strains also supports the validity of the strains and stresses predicted inside the bone. The present study provides a strong rationale for use of this modelling method as a research tool and in possible clinical applications.



This paper is referenced by
10.1016/J.JBIOMECH.2007.06.017
Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations.
Z. Yosibash (2007)
10.1016/j.medengphy.2018.06.004
Mapping anisotropy improves QCT-based finite element estimation of hip strength in pooled stance and side-fall load configurations.
J. Panyasantisuk (2018)
10.1016/j.jbiomech.2014.04.050
Predicting surface strains at the human distal radius during an in vivo loading task--finite element model validation and application.
V. Bhatia (2014)
10.1007/s10237-016-0856-4
Altered architecture and cell populations affect bone marrow mechanobiology in the osteoporotic human femur
T. A. Metzger (2017)
10.1109/IEMBS.2006.260908
Geometric Modeling of Living Tissue for Subject-Specific Finite Element Analysis
M. Tada (2006)
10.1007/s11914-017-0343-6
Physical Activity for Strengthening Fracture Prone Regions of the Proximal Femur
R. Fuchs (2017)
10.3745/KIPSTB.2003.10B.5.503
Design and Implementation of A Medical Image Guided System for Vertebroplasty
G. Tack (2003)
Development of a patient-specific deformable image registration model for breasts using positron emission tomography combined with magnetic resonance imaging by biomechanical strategy
Cheng Xue (2017)
10.1016/j.bone.2012.08.114
Hip fracture discrimination from dual-energy X-ray absorptiometry by statistical model registration.
Tristan Whitmarsh (2012)
10.1109/IEMBS.2000.900802
Biomechanics of distal radius fracture instability
R. D. Heatherly (2000)
10.1016/S1350-4533(98)00054-X
Comparison of geometry-based and CT voxel-based finite element modelling and experimental validation.
M. Lengsfeld (1998)
10.1002/cnm.2530
Accounting for patient variability in finite element analysis of the intact and implanted hip and knee: a review.
Mark Taylor (2013)
Loading Induced Bone Adaptation in the Distal Radius of Women: Influence of Mechanical Environment
Varun A. Bhatia (2013)
10.1016/J.JBIOMECH.2007.02.010
Subject-specific finite element models can accurately predict strain levels in long bones.
E. Schileo (2007)
10.1016/J.IJSOLSTR.2015.05.002
3D meso-scale fracture modelling and validation of concrete based on in-situ X-ray Computed Tomography images using damage plasticity model
Y. Huang (2015)
10.1016/S0021-9290(99)00099-8
Femoral strength is better predicted by finite element models than QCT and DXA.
D. Cody (1999)
10.1007/s10237-016-0822-1
Material model of pelvic bone based on modal analysis: a study on the composite bone
P. Henyš (2017)
10.1016/j.jpor.2018.10.009
Effect of post-osseointegration loading magnitude on the dynamics of peri-implant bone: a finite element analysis and in vivo study.
T. Matsuzaki (2019)
10.1109/TBME.2006.879473
Finite-Element Modeling of Bones From CT Data: Sensitivity to Geometry and Material Uncertainties
F. Taddei (2006)
10.1117/12.428052
Orthopedic surgical analyzer for percutaneous vertebroplasty
G. R. Tack (2001)
10.1016/S0021-9290(00)00036-1
Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models.
H. Weinans (2000)
10.1115/1.1589772
Quantitative computed tomography-based finite element models of the human lumbar vertebral body: effect of element size on stiffness, damage, and fracture strength predictions.
R. Crawford (2003)
10.1016/J.JBIOMECH.2005.07.018
Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy.
F. Taddei (2006)
10.1016/j.cmpb.2009.11.009
Representation of bone heterogeneity in subject-specific finite element models for knee
Anthony G. Au (2010)
10.1007/978-3-319-22997-3_14
Computational Bone Mechanics: From the Cloud to an Orthopedists Mobile Device
Zohar Yosibash (2015)
10.1016/j.jbiomech.2014.01.001
Application of the digital volume correlation technique for the measurement of displacement and strain fields in bone: a literature review.
B. Roberts (2014)
FINITE ELEMENT MODELING OF THE ANTHROPOID MANDIBLE: MANDIBLE MODEL, EXPERIMENTAL VALIDATION, AND ANTHROPOLOGIC APPLICATION
Ruxandra Cristiana (2006)
10.3951/SOBIM.36.9
X 線CT 画像に基づく個体別モデリング
教夫 伊能 (2012)
10.1002/rcs.1418
Generation of mineral density distribution maps from subject-specific models of mandibles - a preliminary study.
Francisco Alister (2012)
10.1007/BF01774015
Stress distributions within the proximal femur during gait and falls: Implications for osteoporotic fracture
J. C. Lotz (2005)
10.1098/rsta.2008.0077
Multiscale investigation of the functional properties of the human femur
L. Cristofolini (2008)
Correlation of the Microstructural and Mechanical Strength of the Trabecular Bone - The Primary Compression Trabeculae in Human Femoral Head -
Myong-Hyun Baek (2009)
See more
Semantic Scholar Logo Some data provided by SemanticScholar