Susceptibility Artifacts In 2DFT Spin-echo And Gradient-echo Imaging: The Cylinder Model Revisited.

C. Bakker, R. Bhagwandien, M. Moerland, M. Fuderer
Published 1993 · Computer Science, Medicine

Save to my Library
Download PDF
Analyze on Scholarcy
Share
Susceptibility-induced geometry and intensity distortions are a familiar observation in MR imaging. In the past few years several attempts have been made to aid in the understanding of susceptibility artifacts by means of simulation studies. Although these studies, which were mostly carried out with simple test objects, have produced some qualitative insight into chi-artifacts, the results lacked precision in describing finer details. In this paper we show the discrepancy between theory and experiment in previous work to be the result of an inadequate theoretical approach. In most studies so far, delta B0 effects are taken into account in the frequency domain, that is, after Fourier transformation of the data. In our view the simulation should follow the actual sequence of events in an imaging experiment and deal with the effect of error fields in the time domain (k-space) already. The correctness of this view is demonstrated here by comparing the results of time and frequency domain simulation against experimental observation for a coaxial cylinder phantom, a widely used model in this type of work. Having established the superiority of the time domain simulation, we demonstrate its use in predicting chi-artifacts under various experimental conditions, for example, in spin-echo and gradient-echo imaging with a reduced number of phase-encoding steps.
This paper references
10.1118/1.595732
NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities.
M. O'donnell (1985)
10.1016/0730-725X(85)90397-2
Susceptibility artefacts in NMR imaging.
K. Luedeke (1985)
10.1002/MRM.1910160103
Magnetic resonance imaging of blood vessels at high fields: In vivo and in vitro measurements and image simulation
S. Ogawa (1990)
10.1016/0730-725X(92)90011-N
Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.
C. Bakker (1992)
10.1016/0730-725X(94)92357-4
Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D.
R. Bhagwandien (1994)
10.1016/0730-725X(88)90133-6
The benefits of increasing spatial resolution as a means of reducing artifacts due to field inhomogeneities.
I. Young (1988)
10.1148/RADIOLOGY.170.2.2911669
Reduction of T2* dephasing in gradient field-echo imaging.
E. Haacke (1989)
10.1148/RADIOLOGY.175.2.2326482
Evaluation of the susceptibility effect on the phase images of a simple gradient echo.
N. Yamada (1990)
Effects of magnetic susceptibility artifacts and motion in evaluating the cervical neural foramina on 3DFT gradient-echo MR imaging.
J. Tsuruda (1991)
10.1016/0022-2364(90)90282-E
Susceptibility artifacts in spin-echo and gradient-echo imaging
S. Posse (1990)
10.1002/MRM.1910230120
Reduction of susceptibility artifact in gradient‐echo imaging
Z. Cho (1992)
10.1016/0022-2364(90)90007-V
Susceptibility-limited resolution in nuclear magnetic resonance microscopy
P. Callaghan (1990)
10.1016/0730-725X(92)90489-M
Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 2D.
R. Bhagwandien (1992)
10.1002/MRM.1910030302
A computer simulation of nuclear magnetic resonance imaging
R. Summers (1986)
Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.
L. Czervionke (1988)
10.1002/MRM.1910130207
Bulk magnetic susceptibility shifts in nmr studies of compartmentalized samples: use of paramagnetic reagents
Ksimon ‐.C. Chu (1990)
10.1016/0730-725X(90)90216-O
Improved contrast at 1.5 tesla using half-Fourier imaging: application to spin-echo and angiographic imaging.
E. Haacke (1990)
10.1088/0031-9155/33/10/001
Calculation of MRI artifacts caused by static field disturbances
A. Ericsson (1988)
10.1002/MRM.1910140108
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
S. Ogawa (1990)
10.1016/0022-2364(88)90174-6
Theory of resonance in magnetically inhomogeneous specimens and some useful calculations
D. Edmonds (1988)



This paper is referenced by
10.1006/JMRE.1999.1900
Microimaging at 14 tesla using GESEPI for removal of magnetic susceptibility artifacts in T(2)(*)-weighted image contrast.
Q. Yang (1999)
10.1080/13645700410020269
Nitinol in Magnetic Resonance Imaging
A. Melzer (2004)
10.1002/1522-2586(200010)12:4<606::AID-JMRI14>3.0.CO;2-J
MR imaging in the presence of vascular stents: A systematic assessment of artifacts for various stent orientations, sequence types, and field strengths
T. Klemm (2000)
Simulation of MRI with Field Nonuniformities
Gholam-Ali Hossein (2017)
10.1007/978-3-642-60272-6_4
Principles of Passive Visualization
M. Ladd (1998)
10.1007/s002239900204
High Resolution Magnetic Resonance Imaging of the Calcaneus: Age-Related Changes in Trabecular Structure and Comparison with Dual X-Ray Absorptiometry Measurements
X. Ouyang (1997)
10.1016/0730-725X(94)92542-9
Solid state and microscopy NMR study of the chemical constituents of Afzelia cuanzensis seeds.
M. Gussoni (1994)
10.1016/S1361-8415(02)00109-3
Numerical determination of the susceptibility caused geometric distortions in magnetic resonance imaging
S. Burkhardt (2003)
10.1002/mrm.25126
Off‐resonance suppression for multispectral MR imaging near metallic implants
J. C. den Harder (2015)
10.1016/J.IJHEATMASSTRANSFER.2004.09.041
Magnetic resonance imaging of water freezing in packed beds cooled from below
J. Georgiadis (2005)
10.1016/S0009-9260(02)00540-8
Metallic artefacts in MR imaging: effects of main field orientation and strength.
A. Guermazi (2003)
10.1078/0939-3889-00169
Artefakte in der MRT durch Instrumente und Implantate
H. Graf (2003)
Metal implant artifact reduction in magnetic resonance imaging
den Jm Chiel Harder (2015)
10.1002/mrm.25127
Ripple artifact reduction using slice overlap in slice encoding for metal artifact correction
J. C. den Harder (2015)
10.1002/JMRI.1880050115
Nonsusceptibility artifacts due to metallic objects in MR imaging
C. R. Camacho (1995)
10.1002/MRM.1910360423
Biopsy needle susceptibility artifacts
M. Ladd (1996)
10.1016/j.jmr.2013.05.002
MR measurement of alloy magnetic susceptibility: towards developing tissue-susceptibility matched metals.
G. Astary (2013)
10.1016/0730-725X(94)92357-4
Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D.
R. Bhagwandien (1994)
10.1117/12.317084
Simulation of MRI with field nonuniformities
G. Hossein-Zadeh (1998)
1 Mapping B 1-induced eddy current effects near metallic structures in MR images : a comparison of simulation and experiment
S. Vashaeea (2014)
10.1016/S0730-725X(00)00208-3
Detection of susceptibility effects using simultaneous T(2)* and magnetic field mapping.
J. Bonny (2000)
10.1002/MRM.1910330112
Echo‐Time Reduction for Submillimeter Resolution Imaging with a 3D Phase Encode Time Reduced Acquisition Method
K. Ying (1995)
Design and Realization of a Scalable Simulator of Magnetic Resonance Tomography
Jurgen Kursch (2003)
10.1016/0730-725X(94)92201-2
Simulation of susceptibility artifacts in 2D and 3D Fourier transform spin-echo and gradient-echo magnetic resonance imaging.
C. Bakker (1994)
Mathematical modeling and numerical simulation of magneticsusceptibility artifacts in Magnetic Resonance
I. Balać (2000)
10.1109/JSEN.2005.843900
Visualization of air bubbles by magnetic resonance imaging
F. Heese (2005)
10.1118/1.598085
Magnetic resonance imaging in radiotherapy treatment planning
M. Moerland (1997)
10.1002/mrm.10004
Improved lumen visualization in metallic vascular implants by reducing RF artifacts
L. Bartels (2002)
10.1002/(SICI)1099-0534(1999)11:6<379::AID-CMR3>3.3.CO;2-G
Simulation of in-plane flow imaging
I. Marshall (1999)
10.1002/1522-2586(200010)12:4<534::AID-JMRI4>3.0.CO;2-Q
Interventional MRA and intravascular imaging
M. Ladd (2000)
10.2136/VZJ2013.08.0158
In Situ Magnetic Resonance Imaging of Plant Roots
M. Gruwel (2014)
10.1002/jmri.10432
Magnetic resonance imaging of periosteum with ultrashort TE pulse sequences
I. Reichert (2004)
See more
Semantic Scholar Logo Some data provided by SemanticScholar