Online citations, reference lists, and bibliographies.
Please confirm you are human
(Sign Up for free to never see this)
← Back to Search

Numerical Analysis Of The Magnetic Field For Arbitrary Magnetic Susceptibility Distributions In 3D.

R. Bhagwandien, M. Moerland, C. J. Bakker, R. Beersma, J. Lagendijk
Published 1994 · Chemistry, Medicine

Save to my Library
Download PDF
Analyze on Scholarcy
Share
This paper demonstrates a method to calculate the magnetic field distribution in and around a 3D object when it is magnetized by a strong homogeneous magnetic field. The numerical technique is based on the explicit finite difference method. The calculation method is validated against analytical solutions for a sphere. As an application cylinders with different ratios of lengths and diameter are studied.
This paper references
10.1148/RADIOLOGY.175.2.2326482
Evaluation of the susceptibility effect on the phase images of a simple gradient echo.
N. Yamada (1990)
10.1016/0022-2364(87)90202-2
A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurements
T. L. Case (1987)
10.1002/MRM.1910180127
Magnetic susceptibility measurement using a double‐DANTE tagging (DDT) sequence
T. Mosher (1991)
10.1016/0730-725X(92)90489-M
Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 2D.
R. Bhagwandien (1992)
10.1016/0360-3016(91)90036-4
Image correlation of MRI and CT in treatment planning for radiosurgery of intracranial vascular malformations.
M. H. Phillips (1991)
10.1097/00004728-198701000-00002
Clinical magnetic susceptibility mapping of the brain.
I. Young (1987)
10.1016/0730-725X(92)90011-N
Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.
C. Bakker (1992)
10.1103/PHYSREV.81.717
The Time Average Magnetic Field at the Nucleus in Nuclear Magnetic Resonance Experiments
W. C. Dickinson (1951)
10.1016/0730-725X(85)90397-2
Susceptibility artefacts in NMR imaging.
K. Luedeke (1985)
10.1002/MRM.1910300316
Magnetic field distribution in models of trabecular bone
J. Ford (1993)
10.1002/MRM.1910130207
Bulk magnetic susceptibility shifts in nmr studies of compartmentalized samples: use of paramagnetic reagents
Ksimon ‐.C. Chu (1990)
10.1016/0730-725X(93)90473-Q
Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: the cylinder model revisited.
C. Bakker (1993)
10.1118/1.595762
Calculation of the uncertainty in the dose delivered during radiation therapy.
M. Goitein (1985)
10.1016/0022-2364(86)90373-2
The effect of magnetic susceptibility variations in NMR imaging and nmr spectroscopy in vivo
I. Cox (1986)
10.1118/1.596703
Multimodality image integration for stereotactic surgical planning.
C. Henri (1991)



This paper is referenced by
10.1002/9780470905203.CH24
Rapid Calculation of Magnetic Field Perturbations from Biological Tissue in Magnetic Resonance Imaging
J. Neelavalli (2011)
10.3929/ETHZ-A-005788903
Spatiotemporal magnetic field monitoring for magnetic resonance systems
C. Barmet (2008)
10.1120/jacmp.v11i1.2961
Investigation of a 3D system distortion correction method for MR images
T. Stanescu (2010)
10.1007/978-3-540-89208-3_590
Random walk simulation of R2-dispersion in foam microstructures
S. Baete (2008)
10.1002/mrm.24323
Optimal magnetic susceptibility matching in 3D
Feng Jia (2013)
10.1016/S1361-8415(02)00109-3
Numerical determination of the susceptibility caused geometric distortions in magnetic resonance imaging
S. Burkhardt (2003)
10.1080/10255840008915276
Mathematical Modeling and Numerical Simulation of Magnetic Susceptibility Artifacts in Magnetic Resonance IMAGING
S. Balac (2000)
10.1097/00004728-199911000-00004
Macroscopic susceptibility in ultra high field MRI.
A. Abduljalil (1999)
Design and evaluation of Overhauser enhanced MRI visible markers
R. Joensuu (2000)
Correction par traitement d'images de l'artéfact de susceptibilité magnétique dans les images IRM
B. Belaroussi (2005)
10.1002/CMR.B.20034
Application of a Fourier‐based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility
J. Marques (2005)
10.1109/10.536905
A 3-D SAR model for current source interstitial hyperthermia
J. de Bree (1996)
10.1002/mrm.21522
Joint estimation of water/fat images and field inhomogeneity map
D. Hernando (2008)
10.1016/J.MRI.2007.03.008
1H-MRS of the macaque monkey primary visual cortex at 7 T: strategies and pitfalls of shimming at the brain surface.
C. Juchem (2007)
Développements de méthodes d'acquisition et de traitement du signal robustes aux défauts du champ magnétique pour la spectroscopie localisée par RMN
Alejandro Bordelois Boizán (2013)
MAGNETIC RESONANCE IMAGE DISTORTIONS DUE TO ARTIFICIAL MACROSCOPIC
A. Koivula (2002)
10.1016/j.mri.2011.01.002
Dynamic B0 shimming at 7 T.
Saikat Sengupta (2011)
10.1109/42.538939
The computation of MR image distortions caused by tissue susceptibility using the boundary element method
J. Munck (1996)
10.1118/1.4915920
Continuous table acquisition MRI for radiotherapy treatment planning: distortion assessment with a new extended 3D volumetric phantom.
A. Walker (2015)
10.1016/S0730-725X(98)00095-2
Magnetic resonance spectroscopic imaging for visualization and correction of distortions in MRI: high precision applications in neurosurgery.
J. Weis (1998)
Quantitative susceptibility mapping and susceptibility-based distortion correction of echo planar images
W. Wells (2012)
Physics of MR image distortion: Impact on breast cancer radiotherapy
Amy Walker (2015)
10.1109/MWSYM.2006.249453
Modeling of Static, Switched, and RF Fields in the Body for MRI
C.M. Collins (2006)
ANALYSE ET CORRECTION DES DISTORSIONS EN IMAGERIE PAR RÉSONANCE MAGNÉTIQUE
M. Langlois (1998)
10.1002/mrm.20927
Prepolarized magnetic resonance imaging around metal orthopedic implants
R. Venook (2006)
10.1016/S0079-6565(02)00003-1
Small animal neuroimaging using magnetic resonance microscopy
E. Ahrens (2002)
10.3390/ijms20030776
MRI Relaxometry for Quantitative Analysis of USPIO Uptake in Cerebral Small Vessel Disease
M. Thrippleton (2019)
10.1088/2057-1976/AACA02
Computation of Magnetic Field Distortions and Impact on T2*-weighted MRI with Application to Magnetic Susceptibility Parameter Estimation.
C. Cruttenden (2018)
10.1002/mrm.27042
Simple and robust referencing system enables identification of dissolved‐phase xenon spectral frequencies
M. Antonacci (2018)
10.1007/BF03194359
High-resolution magnetic resonance imaging of trabecular bone structure
H. Genant (2010)
10.1007/978-3-642-60272-6_11
Safety Issues in the MR Environment
J. Schenck (1998)
Magnetic Resonance Gradient Echo Phase Imaging as a Means of Detecting Alterations in the Tissue Microarchitecture of the Human Corpus Callosum
Sharon Schreiber (2012)
See more
Semantic Scholar Logo Some data provided by SemanticScholar