Adsorption Of Bovine Serum Albumin On CoCrMo Surface: Effect Of Temperature And Protein Concentration.

C. Valero Vidal, A. Olmo Juan, A. Igual Muñoz
Published 2010 · Medicine

Save to my Library
Download PDF
Analyze on Scholarcy
Share
The adsorption of bovine serum albumin (BSA) onto CoCrMo surface has been studied as a function of concentration of BSA and temperature by electrochemical techniques. The electrochemical impedance spectroscopy (EIS) technique was used to investigate the interfacial behaviour of BSA at open circuit potential (OCP). The charge transfer resistance was very sensitive to the amount of adsorbed protein, indicating that the adsorption process was accompanied by the transfer of charge and influenced the mechanism and kinetics of the corrosion reaction. At all the temperatures studied, adsorption of BSA onto the CoCrMo surface was successfully described with a Langmuir adsorption isotherm. EIS study was also carried out for determine the surface charge density, resulting from protein adsorption, and it was shown to be directly proportional to the amount of adsorbed protein (surface concentration). Thermodynamic data of adsorption was obtained for analyzing the adsorption of BSA onto CoCrMo surface. Gibbs free energy of adsorption, DeltaG(ADS) values, for BSA in the investigated temperature range (-51kJmol(-1)) showed that the molecules have a strong affinity for the CoCrMo surface. Enthalpy (DeltaH(ADS)) and entropy (DeltaS(ADS)) of adsorption suggested that the adsorption process of BSA onto the CoCrMo surface is an endothermic process and the molecule suffers structural changes when adsorbing on the metallic surface.



This paper is referenced by
Protein effect on the corrosion behaviour of titanium modified by two surface treatments
Ângela Filipa Esteves Machado Fontela (2011)
10.14288/1.0103423
Corrosion behavior of metallic bio-implant alloys
Shima Karimi (2014)
10.25148/ETD.FIDC000069
The Microstructure and the Electrochemical Behavior of Cobalt Chromium Molybdenum Alloys from Retrieved Hip Implants
Christopher P Emerson (2015)
10.5772/13039
Electrochemical Aspects in Biomedical Alloy Characterization: Electrochemical Impedance Spectrosopy
C. V. Vidal (2011)
10.1080/10826076.2017.1282870
Comparative study of the thermodynamics and extrathermodynamics on the conformational transformation and adsorption of bovine serum albumin
Wenhai Bian (2017)
10.3390/ma7085866
Effect of Mucin and Bicarbonate Ion on Corrosion Behavior of AZ31 Magnesium Alloy for Airway Stents
Y. Jang (2014)
10.1007/s10856-012-4816-y
Influence of albumin on the electrochemical behaviour of Zr in phosphate buffered saline solutions
L. Wang (2012)
10.1002/bmc.3020
Temperature-induced conformational transition of bovine serum albumin in neutral aqueous solution by reversed-phase liquid chromatography.
Liujiao Bian (2014)
10.1007/s40735-016-0063-y
Electrochemically Induced Film Formation on CoCrMo Alloy for Hip Implant Application
S. Kerwell (2016)
10.1016/j.jmbbm.2013.08.018
Tribolayer formation in a metal-on-metal (MoM) hip joint: an electrochemical investigation.
M. T. Mathew (2014)
10.18596/JOTCSA.335012
Analysis of Chemical Compositions of 15 Different Cold-Pressed Oils Produced in Turkey: A Case Study of Tocopherol and Fatty Acid Analysis
Veysel U. Çelenk (2017)
10.1016/j.biomaterials.2012.10.078
A comprehensive study of lysozyme adsorption using dual polarization interferometry and quartz crystal microbalance with dissipation.
K. Xu (2013)
10.1007/s40735-014-0001-9
Wear and Electrochemical Corrosion Behavior of Biomedical Ti–25Nb–3Mo–3Zr–2Sn Alloy in Simulated Physiological Solutions
W. Huang (2014)
10.3390/bios9040138
The Influence of the Parameters of a Gold Nanoparticle Deposition Method on Titanium Dioxide Nanotubes, Their Electrochemical Response, and Protein Adsorption
Ewa Paradowska (2019)
10.1080/00986445.2016.1225197
Influence of Various Albumin Concentrations on the Corrosion Resistance of Zr-2.5%Nb Alloy
Anca Maria Martinof (2016)
13 Electrochemical Aspects in Biomedical Alloy Characterization : Electrochemical Impedance Spectroscopy
C. V. Vidal (2018)
10.14288/1.0377774
Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements
Q. Wang (2019)
10.3389/fbioe.2019.00176
Mechanisms of Adverse Local Tissue Reactions to Hip Implants
Felipe Eltit (2019)
10.1016/j.msec.2014.04.007
Ion release and surface oxide composition of AISI 316L, Co-28Cr-6Mo, and Ti-6Al-4V alloys immersed in human serum albumin solutions.
Shima Karimi (2014)
The effects of simulated inflammatory conditions on the corrosion and fretting corrosion of CoCrMo alloy
Y. Liu (2017)
10.3990/1.9789036537582
Boundary lubrication of stainless steel and CoCrMo in aqueous systems
J. Yan (2014)
10.3389/fbioe.2020.00559
Editorial: Enabling Biomaterials for New Biomedical Technologies and Clinical Therapies
H. Uludag (2020)
10.2478/s11696-014-0549-3
Influence of caffeine and temperature on corrosion-resistance of CoCrMo alloy
M. Romas (2014)
10.18596/JOTCSA.341336
Examination of the Effects of Activated Carbon Produced from Coal Using Single-Step H3PO4/N2+H2O Vapor Activation on the Adsorption of Bovine Serum Albumin at Different Temperatures and pH Values
Atakan Toprak (2017)
10.1016/J.TRIBOINT.2014.08.011
Tribocorrosion behavior and ions release of CoCrMo alloy coated with a TiAlVCN/CNx multilayer in simulated body fluid plus bovine serum albumin
B. Alemon (2015)
10.1007/s10971-012-2755-1
Magnetic properties and BSA adsorption of nano-Fe-embedded BaFe12O19 porous microfibers via organic gel-thermal selective reduction process
Xinchun Yang (2012)
10.1007/s11665-018-3769-9
Tribo-corrosion and Albumin Attachment of Nitrogen Ion-Implanted CoCrMo Alloy During Friction Onset
Xueyan Yan (2018)
10.1007/s11595-020-2322-5
Dynamic Corrosion Trail of Ti-6Al-4V Alloy in Acid Artificial Saliva Containing Fluoride Ion
Lixia Yang (2020)
10.1109/ENBENG.2011.6026086
Corrosion and tribocorrosion behavior of CoCrMo alloys used as hip joint implant materials under simulated body fluids: Effect of proteins and normal load
M. J. Runa (2011)
10.1007/s40735-019-0299-4
Effects of Bovine Serum Albumin and Hyaluronic Acid on the Electrochemical Response of a CoCrMo Alloy to Cathodic and Anodic Excursions
S. Radice (2019)
10.1016/j.jcms.2014.01.029
An electrochemical investigation of TMJ implant metal alloys in an artificial joint fluid environment: the influence of pH variation.
D. Royhman (2014)
10.1139/CJC-2019-0008
Adsorption of bovine serum albumin (BSA) by bare magnetite nanoparticles with surface oxidative impurities that prevent aggregation
S. Rahdar (2019)
See more
Semantic Scholar Logo Some data provided by SemanticScholar