The Effects Of Side-artifacts On The Elastic Modulus Of Trabecular Bone.

Kerem Un, G. Bevill, T. M. Keaveny
Published 2006 · Medicine, Engineering

Cite This
Download PDF
Analyze on Scholarcy
Share
Determining accurate density-mechanical property relationships for trabecular bone is critical for correct characterization of this important structure-function relation. When testing any excised specimen of trabecular bone, an unavoidable experimental artifact originates from the sides of the specimen where peripheral trabeculae lose their vertical load-bearing capacity due to interruption of connectivity, a phenomenon denoted here as the 'side-artifact'. We sought in this study to quantify the magnitude of such side-artifact errors in modulus measurement and to do so as a function of the trabecular architecture and specimen size. Using parametric computational analysis of high-resolution micro-CT-based finite-element models of cores of elderly human vertebral trabecular bone, a specimen-specific correction factor for the side-artifact was quantified as the ratio of the side-artifact-free apparent modulus (Etrue) to the apparent modulus that would be measured in a typical experiment (Emeasured). We found that the width over which the peripheral trabeculae were mostly unloaded was between 0.19 and 0.58 mm. The side-artifact led to an underestimation error in Etrue of over 50% in some specimens, having a mean (+/-SD) of 27+/-11%. There was a trend for the correction factor to linearly increase as volume fraction decreased (p=0.001) and as mean trabecular separation increased (p<0.001). Further analysis indicated that the error increased substantially as specimen size decreased. Two methods used for correcting for the side-artifact were both successful in bringing Emeasured into statistical agreement with Etrue. These findings have important implications for the interpretation of almost all literature data on trabecular bone mechanical properties since they indicate that such properties need to be adjusted to eliminate the substantial effects of side-artifacts in order to provide more accurate estimates of in situ behavior.
This paper references
10.1002/JOR.1100120412
Femoral prosthesis implantation induces changes in bone stress that depend on the extent of porous coating
H. Skinner (1994)
10.1016/0021-9290(89)90067-5
X-ray quantitative computed tomography: the relations to physical properties of proximal tibial trabecular bone specimens.
I. Hvid (1989)
10.1016/S0021-9290(01)00011-2
Dependence of yield strain of human trabecular bone on anatomic site.
E. Morgan (2001)
10.1002/JOR.1100120610
Estimation of material properties in the equine metacarpus with use of quantitative computed tomography
C. Les (1994)
10.1016/0021-9290(93)90021-6
Theoretical analysis of the experimental artifact in trabecular bone compressive modulus.
T. M. Keaveny (1993)
10.1016/S0736-0266(01)00185-1
Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone
D. Kopperdahl (2002)
10.1016/S0021-9290(03)00257-4
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue.
Harun H. Bayraktar (2004)
10.1016/S0021-9290(99)00115-3
The impact of boundary conditions and mesh size on the accuracy of cancellous bone tissue modulus determination using large-scale finite-element modeling
C. Jacobs (1999)
10.1016/0021-9290(91)90006-9
Tensile and compressive properties of cancellous bone.
L. Røhl (1991)
10.1016/S0021-9290(99)00099-8
Femoral strength is better predicted by finite element models than QCT and DXA.
D. Cody (1999)
10.1016/0021-9290(94)90053-1
Trabecular bone exhibits fully linear elastic behavior and yields at low strains.
T. M. Keaveny (1994)
10.2106/00004623-199506000-00012
Mechanical consequences of bone ingrowth in a hip prosthesis inserted without cement.
T. M. Keaveny (1995)
10.1148/RADIOLOGY.179.3.2027972
Effect of bone distribution on vertebral strength: assessment with patient-specific nonlinear finite element analysis.
K. Faulkner (1991)
10.1016/0021-9290(94)90032-9
Effects of specimen load-bearing and free surface layers on the compressive mechanical properties of cellular materials.
M. Zhu (1994)
10.1002/(SICI)1097-0207(20000720)48:8<1241::AID-NME946>3.0.CO;2-R
Parallel multigrid solvers for 3D unstructured finite element problems in large deformation elasticity and plasticity
M. Adams (1999)
10.1016/S8756-3282(03)00210-2
Finite element models predict in vitro vertebral body compressive strength better than quantitative computed tomography.
R. Crawford (2003)
10.1016/0021-9290(91)90333-I
The underestimation of Young's modulus in compressive testing of cancellous bone specimens.
A. Odgaard (1991)
10.1016/0021-9290(88)90257-6
Limitations of the continuum assumption in cancellous bone.
T. Harrigan (1988)
10.1644/1545-1542(2003)084<0779:SFAFMO>2.0.CO;2
Skeletal Function and Form: Mechanobiology of Skeletal Development, Aging, and Regeneration
D. Carter (2000)
10.1007/s00223-002-2066-6
Canine Cancellous Bone Microarchitecture after One Year of High-Dose Bisphosphonates
M. Ding (2003)
10.1002/JOR.1100150115
Systematic and random errors in compression testing of trabecular bone
T. M. Keaveny (1997)
10.1016/J.BONE.2004.12.009
Influence of estrogen therapy at conventional and high doses on the degree of mineralization of iliac bone tissue: a quantitative microradiographic analysis in postmenopausal women.
G. Boivin (2005)
Accurate prediction of vertebral strength using voxel-based non-linear finite element models
P. Crawford (2004)
10.1016/S1350-4533(01)00045-5
Improved prediction of proximal femoral fracture load using nonlinear finite element models.
J. Keyak (2001)
10.1016/8756-3282(88)90038-5
Age-related changes in vertebral trabecular bone architecture--assessed by a new method.
L. Mosekilde (1988)
10.1016/S8756-3282(00)00371-9
Parallel plate model for trabecular bone exhibits volume fraction-dependent bias.
J. S. Day (2000)
10.1359/jbmr.1999.14.7.1167
Direct Three‐Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus
T. Hildebrand (1999)
10.1016/J.BONE.2006.06.001
A biomechanical perspective on bone quality.
C. Hernandez (2006)
10.1109/SC.2004.62
Ultrascalable Implicit Finite Element Analyses in Solid Mechanics with over a Half a Billion Degrees of Freedom
M. F. Adams (2004)
10.1016/0021-9290(83)90072-6
A survey of finite element analysis in orthopedic biomechanics: the first decade.
R. Huiskes (1983)



This paper is referenced by
Hierarchical analysis and multiscale modelling of cellular structures: from meta materials to bone structure.
R. Oftadeh (2016)
10.1007/s11517-011-0833-0
Mechanical and microarchitectural analyses of cancellous bone through experiment and computer simulation
A. Syahrom (2011)
10.1016/j.jmbbm.2009.03.002
Investigation of the mechanical interaction of the trabecular core with an external shell using rapid prototype and finite element models.
P. M. Mc Donnell (2010)
10.1115/1.4000192
Scale and boundary conditions effects on the apparent elastic moduli of trabecular bone modeled as a periodic cellular solid.
C. Wang (2009)
10.1115/1.4029176
Biomechanics and mechanobiology of trabecular bone: a review.
R. Oftadeh (2015)
RELATIONSHIPS OF LONG-TERM BISPHOSPHONATE TREATMENT WITH MEASURES OF BONE MICROARCHITECTURE AND MECHANICAL COMPETENCE
J. J. Ward (2014)
10.1016/j.jmbbm.2009.02.001
Minimizing specimen length in elastic testing of end-constrained cancellous bone.
W. Lievers (2010)
10.1016/j.jmbbm.2018.10.013
Development of a validated glenoid trabecular density-modulus relationship.
N. Knowles (2019)
Strain rate and density dependent behaviour of bovine cancellous bone in compression
Suzanne Higgins (2008)
10.1115/1.4028968
Comparison of mixed and kinematic uniform boundary conditions in homogenized elasticity of femoral trabecular bone using microfinite element analyses.
J. Panyasantisuk (2015)
10.1016/j.medengphy.2019.02.005
A comparison of density-modulus relationships used in finite element modeling of the shoulder.
N. Knowles (2019)
10.1002/jbmr.2291
Prediction of Incident Hip Fracture with the Estimated Femoral Strength by Finite Element Analysis of DXA Scans in the Study of Osteoporotic Fractures
L. Yang (2014)
10.1089/ten.2007.0051
Ex VivoBone Formation in Bovine Trabecular Bone Cultured in a Dynamic 3D Bioreactor Is Enhanced by Compressive Mechanical Strain
V. David (2008)
10.14288/1.0319083
Quantifying the response of vertebral bodies to compressive loading using digital image correlation
Hannah M Gustafson (2016)
10.1016/J.JBIOMECH.2007.05.008
Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site.
G. Bevill (2007)
3-D visualization and prediction of spine fractures under axial loading
H. Ali (2013)
Title Ex vivo bone formation in bovine trabecular bone cultured in a dynamic 3 D bioreactor is enhanced by compressive mechanical strain Authors
V. David (2017)
In vivo assessment of changes in bone due to osteoporosis and its possible treatments
H. Huiskes (2004)
10.1016/j.jmbbm.2011.05.032
Study of the behavior of the trabecular bone under cyclic compression with stepwise increasing amplitude.
T. Topoliński (2011)
10.1002/jor.23335
Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures
Joseph L. Petfield (2017)
10.1007/978-3-319-28329-6_11
Some Use Cases for Composite Finite Elements in Image Based Computing
Lars Ole Schwen (2016)
10.1359/jbmr.061011
Effects of Teriparatide and Alendronate on Vertebral Strength as Assessed by Finite Element Modeling of QCT Scans in Women With Osteoporosis
T. M. Keaveny (2007)
10.1201/9780429186745-8
Cellular or Trabecular Solids
S. R. Stock (2019)
10.1163/092764410X513440
Effects of Filler Content on Mechanical Properties of Macroporous Composites
Chi Pong Tsui (2010)
10.1016/j.cmpb.2020.105484
Prediction of osteoporotic hip fracture in postmenopausal women through patient-specific FE analyses and machine learning
E. Villamor (2020)
10.1007/s10439-007-9363-1
The Effect of Regional Variations of the Trabecular Bone Properties on the Compressive Strength of Human Vertebral Bodies
Do-Gyoon Kim (2007)
10.1016/j.jmbbm.2012.07.005
Fabric-based Tsai-Wu yield criteria for vertebral trabecular bone in stress and strain space.
U. Wolfram (2012)
10.1177/0954411913486855
Apparent elastic modulus of ex vivo trabecular bovine bone increases with dynamic loading
Juan F. Vivanco (2013)
10.1115/1.4027663
Dependence of anisotropy of human lumbar vertebral trabecular bone on quantitative computed tomography-based apparent density.
A. Aiyangar (2014)
10.1016/j.jbiomech.2011.02.082
Fast and accurate specimen-specific simulation of trabecular bone elastic modulus using novel beam-shell finite element models.
J. Vanderoost (2011)
10.5277/ABB-00967-2017-03
The effect of trabecular bone storage method on its elastic properties.
A. Mazurkiewicz (2018)
Modelowanie konstytutywne tkanki kostnej i materiałów poliuretanowych do zastosowań w chirurgii ortopedycznej
M. Pawlikowski (2013)
See more
Semantic Scholar Logo Some data provided by SemanticScholar