Abstract In this work, we present a label -free impedimetric aptasensor for the recognition of cytochrome c (Cyt c) at a pM concentration level based on an epoxy-graphite composite electrode. The technique employed for the detection of the protein Cyt c is electrochemical impedance spectroscopy (EIS). Detection occurs when the protein interacts with the immobilized aptamer on the aptasensor. The aptamer immobilization technique is based on its wet physical adsorption onto the electrode surface, which assures a simple, ready-to-use preparation of the biosensing platform. The work first optimizes concentration of immobilized aptamer, followed by blocking agent to avoid non specific interactions, and finally performs the label-free detection of Cyt c. The amount of protein is quantified by the observed increase of the electron-transfer resistance, determined employing EIS and the [Fe(CN)6]3−,4− redox marker. Results demonstrate that the aptasensor has a good detection range for Cyt c between 50 pM and 50 nM, as well as a high sensitivity with a low detection limit of 63.2 pM, well below levels of this protein in serum. Cross response of the developed aptamer biosensor versus potential interfering proteins also present in human serum has been fully characterized.
This paper references
10.1039/C0JA00232A
Ultrasensitive, selective and simultaneous detection of cytochrome c and insulin based on immunoassay and aptamer-based bioassay in combination with Au/Ag nanoparticle tagging and ICP-MS detection
Jing-Min Liu (2011)
10.1021/AC0505775
Reusable impedimetric aptasensor.
A. Radi (2005)
10.1016/j.bbrc.2010.04.066
Aptamer-based bio-barcode assay for the detection of cytochrome-c released from apoptotic cells.
Irene Lau (2010)
10.1021/ac702567x
Aptamer-modified monolithic capillary chromatography for protein separation and detection.
Q. Zhao (2008)
10.1016/S0162-3109(99)00020-X
Derivation of RNA aptamer inhibitors of human complement C5.
G. Biesecker (1999)
10.1002/ELAN.201000686
Electrochemical Impedance Spectroscopy for Assessing the Recognition of Cytochrome c by Immobilized Calixarenes
M. Mohsin (2011)
10.1016/J.ELECTACTA.2007.11.030
Signal amplification for impedimetric genosensing using gold-streptavidin nanoparticles
A. Bonanni (2008)
10.1146/ANNUREV.MED.56.062904.144915
Aptamers: an emerging class of therapeutics.
S. Nimjee (2005)
10.1111/J.1432-1033.1992.TB16884.X
Presteady-state and steady-state kinetic properties of human cytochrome c oxidase. Identification of rate-limiting steps in mammalian cytochrome c oxidase.
A. V. van Kuilenburg (1992)
10.3390/s120303037
A Reusable Impedimetric Aptasensor for Detection of Thrombin Employing a Graphite-Epoxy Composite Electrode
Cristina Ocaña (2012)
10.1021/AC991112F
Separation of nontarget compounds by DNA aptamers.
R. B. Kotia (2000)
10.1016/j.talanta.2012.07.007
Label-free aptasensor for thrombin determination based on the nanostructured phenazine mediator.
G. Evtugyn (2012)
10.3748/wjg.v17.i39.4389
Paris chinensis dioscin induces G2/M cell cycle arrest and apoptosis in human gastric cancer SGC-7901 cells.
L. Gao (2011)
10.1021/AC052289E
Following aptamer-thrombin binding by force measurements.
B. Basnar (2006)
10.1016/J.TRAC.2004.11.007
New materials for electrochemical sensing V: Nanoparticles for DNA labeling
A. Merkoçi (2005)
10.1016/J.ELECTACTA.2007.04.001
The corrosion inhibition mechanism of new rare earth cinnamate compounds — Electrochemical studies
F. Blin (2007)
10.1007/S00216-006-0558-3
Impedimetric genosensors for the detection of DNA hybridization
A. Bonanni (2006)
10.1093/clinchem/45.9.1628
Aptamers: an emerging class of molecules that rival antibodies in diagnostics.
S. Jayasena (1999)
10.1016/J.TRAC.2005.03.019
New materials for electrochemical sensing VI: Carbon nanotubes
A. Merkoçi (2005)
10.1016/J.ELECTACTA.2005.01.035
Direct voltammetric determination of gold nanoparticles using graphite-epoxy composite electrode
M. Pumera (2005)
10.1039/c2nr11492e
Impedimetric immunoglobulin G immunosensor based on chemically modified graphenes.
A. Loo (2012)
10.1016/J.JELECHEM.2006.12.008
Electrochemical investigation of DNA-modified surfaces: From quantitation methods to experimental conditions
B. Ge (2007)
10.1039/c3an00229b
Development of a label-free aptasensor for monitoring the self-association of lysozyme.
A. Vasilescu (2013)
10.1166/SL.2012.2335
Piezoresistive Microcantilevers-Based Cocaine Biosensors
B. Srijanto (2012)
10.1042/BA20060103
Serum cytochrome c detection using a cytochrome c oxidase biosensor
D. Ashe (2007)
10.1016/j.bios.2010.06.047
Impedimetric genosensing of DNA polymorphism correlated to cystic fibrosis: a comparison among different protocols and electrode surfaces.
A. Bonanni (2010)
10.1016/j.aca.2012.07.027
Label-free electrochemical impedance detection of kinase and phosphatase activities using carbon nanofiber nanoelectrode arrays.
Yifen Li (2012)
10.1016/J.JDENT.2006.11.011
In situ tracing the process of human enamel demineralization by electrochemical impedance spectroscopy (EIS).
Y. Liao (2007)
10.1002/ELAN.200390114
Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme Biosensors
Eugenii Katz (2003)
10.1016/j.bioelechem.2012.09.004
Nanomaterial-based electrochemical biosensors for cytochrome c using cytochrome c reductase.
M. Pandiaraj (2013)
10.1039/A808319C
Sensing and amplification of oligonucleotide-DNA interactions by means of impedance spectroscopy: a route to a Tay–Sachs sensor
A. Bardea (1999)
10.1016/S0165-9936(03)01208-1
New trends in affinity sensing: aptamers for ligand binding
E. Luzi (2003)
10.1006/ABIO.2000.4595
A fiber-optic microarray biosensor using aptamers as receptors.
M. Lee (2000)
10.1016/j.aca.2010.08.022
Use of nanomaterials for impedimetric DNA sensors: a review.
A. Bonanni (2010)



This paper is referenced by
10.1016/j.bios.2015.12.069
A novel bio-electronic tongue using different cellobiose dehydrogenases to resolve mixtures of various sugars and interfering analytes.
Andrea Cipri (2016)
10.1002/advs.201701074
Real‐Time Cellular Cytochrome C Monitoring through an Optical Microfiber: Enabled by a Silver‐Decorated Graphene Nanointerface
H. Li (2018)
10.1039/C7NJ03844E
Label-free detection of cytochrome C by a conducting polymer-based impedimetric screen-printed aptasensor
A. Shafaat (2018)
10.1016/J.TRAC.2015.03.006
Recent developments in recognition elements for chemical sensors and biosensors
Celine I. L. Justino (2015)
10.1016/j.bios.2015.03.028
Label-free impedimetric aptasensor for detection of femtomole level acetamiprid using gold nanoparticles decorated multiwalled carbon nanotube-reduced graphene oxide nanoribbon composites.
Airong Fei (2015)
10.1007/s00604-015-1540-6
Aptamer-antibody sandwich assay for cytochrome c employing an MWCNT platform and electrochemical impedance
Cristina Ocaña (2015)
Development of a Voltammetric Sensor for Theophylline with Sol-Gel Immobilised Molecularly Imprinted Polymer Particles
F. Bates (2014)
10.3390/s18020354
Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy
Dionisia Ortiz-Aguayo (2018)
10.1080/05704928.2017.1328425
Exploring the use of impedance spectroscopy in relaxation and electrochemical studies
Dong-Myeong Shin (2018)
10.1016/J.SNB.2016.01.069
Glutathione modified Ag2Te nanoparticles as a resonance Rayleigh scattering sensor for highly sensitive and selective determination of cytochrome C
Shuguang Yan (2016)
10.1039/C6AY01705C
An electrochemical impedance sensor for simple and specific recognition of G–G mismatches in DNA
M. Huang (2016)
10.1134/S1061934817040141
An electrochemical aptasensor for cytochrome C, based on pillar[5]arene modified with Neutral Red
V. Stepanova (2017)
A review on impedimetric biosensors
Elif Burcu Bahad (2014)
10.1021/acs.analchem.5b03824
Detection of Early Stage Apoptotic Cells Based on Label-Free Cytochrome c Assay Using Bioconjugated Metal Nanoclusters as Fluorescent Probes.
M. Shamsipur (2016)
10.1080/03067319.2015.1137910
An electrochemical sensor based on TiO2/activated carbon nanocomposite modified screen printed electrode and its performance for phenolic compounds detection in water samples
A. Hayat (2016)
10.1007/s00449-017-1799-6
An interdigital array microelectrode aptasensor based on multi-walled carbon nanotubes for detection of tetracycline
Wenjie Hou (2017)
10.1007/s00604-014-1413-4
Voltammetric sensor for theophylline using sol–gel immobilized molecularly imprinted polymer particles
F. Bates (2014)
10.1016/j.talanta.2014.08.072
A simple and sensitive impedimetric aptasensor for the detection of tumor markers based on gold nanoparticles signal amplification.
X. Liu (2015)
10.1016/j.bios.2016.09.013
Recent advances in cytochrome c biosensing technologies.
P. Manickam (2017)
10.3109/21691401.2014.942456
A review on impedimetric biosensors
E. Bahadır (2016)
Adaptation of biofuel cell technology for electricity generation from wastewater and lactose measurement
A. Bakar (2015)
10.1016/j.bios.2015.07.032
A high sensitive electrochemical aptasensor for the determination of VEGF(165) in serum of lung cancer patient.
Mahmoud Amouzadeh Tabrizi (2015)
10.1016/J.SNB.2018.11.004
A label-free cytochrome c photoelectrochemical aptasensor based on CdS/CuInS2/Au/TiO2 nanotubes
L. Wang (2019)
10.1002/9781119468455.ch95
Electrochemical Biosensors Based on Green Synthesized Graphene and Graphene Nanocomposites
Mahmoud Amouzadeh Tabrizi (2019)
10.1016/j.microc.2020.104991
Paper-based chemiluminescence and colorimetric detection of cytochrome c by cobalt hydroxide decorated mesoporous carbon
Fazeleh Mesgari (2020)
10.1016/BS.COAC.2016.03.021
Chapter 6 – Aptamers as Synthetic Receptors for Food Quality and Safety Control
R. Miranda-Castro (2016)
Jurnal Teknologi Full Paper 9 , 10-ANTHRAQUINONE-2 , 6-DISULFONIC ACID DISODIUM SALT / EPOXY GRAPHITE COMPOSITE FOR ANODE IN MICROBIAL FUEL CELL
M. H. Bakar (2017)
10.1016/J.SNB.2016.09.108
Simultaneous determination of CYC and VEGF165 tumor markers based on immobilization of flavin adenine dinucleotide and thionine as probes on reduced graphene oxide-poly(amidoamine)/gold nanocomposite modified dual working screen-printed electrode
Mahmoud Amouzadeh Tabrizi (2017)
10.37256/FCE.112020178.1-8
Detection of cytochrome C using a selective and sensitive methylene blue-based electrochemical aptasensor
Mohadeseh Safaei (2019)
10.3390/jcs4030088
Fabrication and Characterization of Flexible Three-Phase ZnO-Graphene-Epoxy Electro-Active Thin-Film Nanocomposites: Towards Applications in Wearable Biomedical Devices
Mandeep Singh (2020)
10.1016/j.ab.2017.10.016
Helix structure of the double-stranded DNA for aptameric biosensing and imaging of cytochrome c.
Somayeh Jamshidi Moghadam (2018)
10.1016/J.SNB.2015.11.023
Label-free electrochemical aptasensor for cytochrome c detection using pillar[5]arene bearing neutral red
V. Stepanova (2016)
See more
Semantic Scholar Logo Some data provided by SemanticScholar