The Microclimate Analysis Of Tezone ‘105’ Of The Venetian Arsenale

M. Strada, A. Carbonari, F. Peron, L. Porciani, P. Romagnoni
Published 2002 · Environmental Science

Save to my Library
Download PDF
Analyze on Scholarcy Visualize in Litmaps
Share
Reduce the time it takes to create your bibliography by a factor of 10 by using the world’s favourite reference manager
Time to take this seriously.
Get Citationsy
This paper presents a detailed analysis of the measured data on the indoor air of an historical building: tezone 105 of the Arsenale in Venice. During one year of measurements, the indoor air temperature and the air humidity have been collected: the probes have been placed in different sites in order to provide total control of the microclimate. The status of the internal walls has been checked by means of the measurement of the surface temperatures by different sets of thermal resistances. The data collected point out the water wall imbibition and the high thermal capacity of the building envelope. The collected information could be used for the design of the thermal system.