Online citations, reference lists, and bibliographies.

Presence Of Corrosion Products And Hypersensitivity-associated Reactions In Periprosthetic Tissue After Aseptic Loosening Of Total Hip Replacements With Metal Bearing Surfaces.

Monika Huber, Georg Reinisch, Günter Trettenhahn, Karl A Zweymüller, Felix K. Lintner
Published 2009 · Materials Science, Medicine
Cite This
Download PDF
Analyze on Scholarcy
Share
Aseptic loosening of articular implants is frequently associated with tissue reactions to wear particles. Some patients, who had received metal-on-metal articulations, present early symptoms including persistent pain and implant failure. These symptoms raise the suspicion about the development of an immunological response. Furthermore, the generation of rare corrosion products in association with metallic implants has been observed. Corrosion products are known to enhance third-body wear and contribute to the loss of the implant. The purpose of this study was to investigate periprosthetic tissue containing solid corrosion products after aseptic loosening of second-generation metal-on-metal total hip replacements made of low-carbon cobalt-chromium-molybdenum alloy for the presence of immunologically determined tissue changes. Periprosthetic tissue of 11 cases containing uncommon solid deposits was investigated by light microscopy. In order to confirm the presence of corrosion products, additional methods including scanning electron microscopy (SEM) investigation, energy dispersive X-ray (EDX) and Fourier transform infrared microspectroscopy (FTIR) analysis were used. All investigated cases revealed solid chromium orthophosphate corrosion products as well as metallic wear particles to a various extent. Moreover, various intense tissue reactions characteristic of immune response were observed in all cases. The simultaneous presence of corrosion products and hypersensitivity-associated tissue reaction indicates that a relationship between corrosion development and implant-related hypersensitivity may exist.



This paper is referenced by
Biomateriais e reacções de hipersensibilidade - um problema ortopédico?
Ciências da Saúde (2011)
10.1007/s11999-013-3157-6
High Rate of Infection After Aseptic Revision of Failed Metal-on-Metal Total Hip Arthroplasty
Cody C Wyles (2014)
10.1533/9780857098603.1.45
Fretting corrosion processes and wear mechanisms in medical implants
J. Michael. . Geringer (2013)
10.1302/0301-620X.94B2.27247
Mixing and matching causing taper wear: corrosion associated with pseudotumour formation.
Rishi Chana (2012)
10.14288/1.0377774
Corrosion associated failure mechanisms of CoCrMo alloys in total hip replacements
Qiong Wang (2019)
10.17554/ijo.v4i4.1998
Degradation of Polymeric Material used for Osteosynthesis and Comparison of Fracture Toughness between Test and FEA
Bijoy Kumer Paul (2017)
10.1002/jbm.a.34619
Large-diameter metal-on-metal total hip arthroplasties: a page in orthopedic history?
Gurpal Singh (2013)
10.1016/j.bjoms.2014.02.010
Tribocorrosion and oral and maxillofacial surgical devices.
Mathew T. Mathew (2014)
10.1016/J.SURFCOAT.2014.07.016
Tribological behavior of a Ta-based coating on a Co–Cr–Mo alloy
Cristina Balagna (2014)
10.1002/jor.22916
Adverse local tissue reaction (ALTR) associated with corrosion products in metal-on-metal and dual modular neck total hip replacements is associated with upregulation of interferon gamma-mediated chemokine signaling.
Kritti Kolatat (2015)
10.1007/s00775-017-1464-1
Are clinical findings of systemic titanium dispersion following implantation explained by available in vitro evidence? An evidence-based analysis
Justin Paul Curtin (2017)
10.1016/J.SAB.2018.12.008
Recent advances in chromium speciation in biological samples
Radka Pechancová (2019)
10.1533/9780857093738.3.401
Fretting corrosion in biomedical implants
J. Michael. . Geringer (2011)
10.5301/JABB.2010.865
Nanotoxicology of metal wear particles in total joint arthroplasty: a review of current concepts.
F Billi (2010)
10.1016/j.prp.2017.03.014
Supramacroparticulate PE in 6 different joint endoprostheses localisations: An indicator for PE damage?
S. Krenn (2017)
10.1055/s-0038-1677467
Imaging of Hip Arthroplasties: Normal Findings and Hardware Complications
Swati D. Deshmukh (2019)
10.2106/JBJS.N.01121
Comprehensive Analysis of a Recalled Modular Total Hip System and Recommendations for Management.
Danyal H. Nawabi (2016)
10.1520/STP159120140139
Method for Characterization of Material Loss from Modular Head-Stem Taper Surfaces of Hip Replacement Devices
Radu Racasan (2015)
10.1302/0301-620X.98B7.37029
The clinical implications of metal debris release from the taper junctions and bearing surfaces of metal-on-metal hip arthroplasty: joint fluid and blood metal ion concentrations.
Raghavendra Prasad Sidaginamale (2016)
10.4172/2155-6121.1000243
Nickel Hypersensitivity: A General Review on Clinical Aspects and Potential Co-Morbidities
Gianfranco Calogiuri (2016)
10.1002/jor.22431
Material loss at the taper junction of retrieved large head metal-on-metal total hip replacements.
Ashley K Matthies (2013)
10.1016/j.arth.2015.03.010
Corrosion and Fretting of a Modular Hip System: A Retrieval Analysis of 60 Rejuvenate Stems.
Ivan De Martino (2015)
10.1055/s-0034-1396764
Imaging of adverse reactions to metal debris.
Ezekiel Maloney (2015)
10.1038/s41529-018-0029-2
Understanding the reactivity of CoCrMo-implant wear particles
Mohamed A. Koronfel (2018)
10.1002/jat.3039
Toxicology-based cancer causation analysis of CoCr-containing hip implants: a quantitative assessment of genotoxicity and tumorigenicity studies.
Whitney V. Christian (2014)
10.2106/JBJS.I.00695
Postmortem study of femoral osteolysis associated with metal-on-metal articulation in total hip replacement: an analysis of nine cases.
Monika Huber (2010)
10.1016/j.prp.2014.09.017
Revised histopathological consensus classification of joint implant related pathology.
V. T. Krenn (2014)
10.1007/s00590-012-1088-7
Catastrophic failure due to massive osteolysis of both acetabular and femoral components in a metal-on-metal hip arthroplasty: a demonstrative case report
Gabriel Gutman (2012)
10.1016/j.arth.2013.05.032
Wear analysis of 39 conserve plus metal-on-metal hip resurfacing retrievals.
Karren M. Takamura (2014)
10.1016/j.arth.2011.04.029
Metal-on-metal vs metal-on-improved polyethylene bearings in total hip arthroplasty.
Ryan G Molli (2011)
10.3109/17453674.2010.519169
Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty
Anton H. Hosman (2010)
10.1007/s40735-018-0188-2
SMART Biosensor for Early Diagnostic Detection of Metal Ion Release in Orthopedic Patients: Initial Outcome
Mathew T. Mathew (2018)
See more
Semantic Scholar Logo Some data provided by SemanticScholar