Modular junctions in total hip arthroplasty are susceptible to mechanically assisted crevice corrosion, leading to the release of metal wear debris. Adverse local tissue reactions result from an immune-mediated biological reaction to this debris and can have a profound effect on the surrounding periarticular soft tissue envelope. Patients often present with pain or muscle weakness and demonstrate elevated serum cobalt and chromium levels. Serum inflammatory markers and synovial fluid tests help distinguish these reactions from deep infection in the majority of cases; however, the presence of amorphous material or fragmented cells can lead to difficulty in some cases. Advanced cross-sectional imaging is essential in establishing the diagnosis. Early revision surgery is generally the treatment of choice for symptomatic adverse local tissue reaction from corrosion at the modular head-neck junction. The existing stem is retained, and a new ceramic head is placed on the existing trunnion whenever possible. This strategy generally leads to short-term improvement of symptoms with reliable clinical outcomes; however, longer term results are presently lacking.
This paper references
10.1016/j.arth.2015.07.039
Diagnosis and Management of Adverse Local Tissue Reactions Secondary to Corrosion at the Head-Neck Junction in Patients With Metal on Polyethylene Bearings.
Darren Plummer (2016)
10.1016/j.arth.2014.07.029
Risk stratification algorithm for management of patients with dual modular taper total hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons and the Hip Society.
Young-Min Kwon (2014)
10.1016/j.arth.2015.02.019
A High Prevalence of Corrosion at the Head-Neck Taper with Contemporary Zimmer Non-Cemented Femoral Hip Components.
Brian J. McGrory (2015)
10.1016/j.arth.2016.03.029
Corrosion at the Head-Neck Junction: Why Is This Happening Now?
Joshua J. Jacobs (2016)
10.1016/j.artd.2015.10.001
Custom titanium sleeve for surgical treatment of mechanically assisted crevice corrosion in the well-fixed, noncontemporary stem in total hip arthroplasty
Thomas Leibiger (2015)
10.1007/S11999-014-3902-5
Do serologic and synovial tests help diagnose infection in revision hip arthroplasty with metal-on-metal bearings or corrosion?
Carl Deirmengian (2015)
10.1016/j.arth.2014.03.055
Do you have to remove a corroded femoral stem?
Nitin Goyal (2014)
10.1007/s11999-013-3096-2
Do Ceramic Femoral Heads Reduce Taper Fretting Corrosion in Hip Arthroplasty? A Retrieval Study
Steven M Kurtz (2013)
10.1007/s11999-014-3579-9
What Are the Advantages and Disadvantages of Imaging Modalities to Diagnose Wear-related Corrosion Problems?
Denis Nam (2014)
10.1016/j.arth.2011.11.007
Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips.
J Caitlin Huot Carlson (2012)
Taper corrosion presenting as late instability following metal-on-polyethylene total hip arthroplasty
HJ Cooper (2015)
10.1007/s11999-014-3972-4
CORR Insights®: Do Serologic and Synovial Tests Help Diagnose Infection in Revision Hip Arthroplasty With Metal-on-metal Bearings or Corrosion?
Carl A. Deirmengian (2015)
Taper corrosion presenting as late instability following metal-on-polyethylene total hip arthroplasty
HJ Cooper (2015)
10.1007/s11999-012-2780-y
Severe Metal-induced Osteolysis Many Years After Unipolar Hip Endoprosthesis
Matthew A Mann (2013)
10.1053/J.SART.2013.01.013
Biologic Implications of Taper Corrosion in Total Hip Arthroplasty
H John Cooper (2012)
10.1302/0301-620X.98B2.36593
Delayed dislocation following metal-on-polyethylene arthroplasty of the hip due to 'silent' trunnion corrosion.
Nicholas J Lash (2016)
10.1016/j.arth.2014.11.023
Gross trunnion failure after primary total hip arthroplasty.
Samik Banerjee (2015)
10.2106/JBJS.K.01352
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty.
H John Cooper (2012)
10.1007/s11999-014-3902-5
Do Serologic and Synovial Tests Help Diagnose Infection in Revision Hip Arthroplasty With Metal-on-metal Bearings or Corrosion?
Paul H. Yi (2015)
10.1007/s11999-013-3133-1
Adverse Local Tissue Reaction Associated With a Modular Hip Hemiarthroplasty
Michael R Whitehouse (2013)



This paper is referenced by
10.1016/j.arth.2018.03.061
The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty.
Young-Min Kwon (2018)
Title Page Title: Low failure rate at short term for 40mm heads and second generation triple annealed HCLPE liners in hybrid Hip Replacements Running Title: Thin Second Generation Highly cross linked Polyethylene low revision rate and large diameter heads
Rajkumar Thangaraj (2018)
10.1016/j.jcot.2017.12.008
Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.
Rajkumar Thangaraj (2019)
10.1016/j.artd.2020.01.004
Successful reimplantation surgery after extraction of well-fixed cementless stems by femoral longitudinal split procedure
Satoshi Nagoya (2020)
10.1177/1120700019869616
Revision of a dual-modular stem in patients with adverse tissue reaction
Carl T. Talmo (2019)
10.1016/j.oto.2019.100732
Diagnosis and Management of Adverse Reactions to Metal Debris.
Richard A Wawrose (2019)
10.1007/s40735-018-0188-2
SMART Biosensor for Early Diagnostic Detection of Metal Ion Release in Orthopedic Patients: Initial Outcome
Mathew T. Mathew (2018)
10.1016/j.arth.2017.04.016
Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty.
Yale A. Fillingham (2017)
10.1302/0301-620X.100B1.BJJ-2017-0569.R1
Trunnion corrosion
James Robert Berstock (2018)
10.1016/j.arth.2019.11.031
Cobalt and Chromium Ion Release in Metal-on-Polyethylene and Ceramic-on-Polyethylene THA: A Simulator Study With Cellular and Microbiological Correlations.
Cody C Wyles (2019)
Trunnion corrosion : What surgeons need to know in 2018
(2018)
10.1016/j.artd.2017.09.001
Pseudotumor in ceramic-on-metal total hip arthroplasty
Yoni M. Blau (2017)
Semantic Scholar Logo Some data provided by SemanticScholar