A New Approach To Determine The Accuracy Of Morphology-elasticity Relationships In Continuum FE Analyses Of Human Proximal Femur.

J. Hazrati Marangalou, K. Ito, B. van Rietbergen
Published 2012 · Medicine, Engineering

Cite This
Download PDF
Analyze on Scholarcy
Share
Continuum finite element (FE) models of bones are commonly generated based on CT scans. Element material properties in such models are usually derived from bone density values using some empirical relationships. However, many different empirical relationships have been proposed. Most of these will provide isotropic material properties but relationships that can provide a full orthotropic elastic stiffness tensor have been proposed as well. Presently it is not clear which of these relationships best describes the material behavior of bone in continuum models, nor is it clear to what extent anisotropic models can improve upon isotropic models. The best way to determine the accuracy of such relationships for continuum analyses would be by quantifying the accuracy of the calculated stress/strain distribution, but this requires an accurate reference distribution that does not depend on such empirical relationships. In the present study, we propose a novel approach to generate such a reference stress distribution. With this approach, stress results obtained from a micro-FE model of a whole bone, that can represent the bone trabecular architecture in detail, are homogenized and the homogenized stresses are then used as a reference for stress results obtained from continuum models. The goal of the present study was to demonstrate this new approach and to provide examples of comparing continuum models with anisotropic versus isotropic material properties. Continuum models that implemented isotropic and orthotropic material definitions were generated for two proximal femurs for which micro-FE results were available as well, one representing a healthy and the other an osteoporotic femur. It was found that the continuum FE stress distributions calculated for the healthy femur compared well to the homogenized results of the micro-FE although slightly better for the orthotropic model (r=0.83) than for the isotropic model (r=0.79). For the osteoporotic bone also, the orthotropic model did better (r=0.83) than the isotropic model (r=0.77). We propose that this approach will enable a more relevant and accurate validation of different material models than experimental methods used so far.
This paper references
10.1016/j.bone.2011.10.020
Determination of vertebral and femoral trabecular morphology and stiffness using a flat-panel C-arm-based CT approach.
L. Mulder (2012)
10.1007/S10237-006-0073-7
The role of fabric in the quasi-static compressive mechanical properties of human trabecular bone from various anatomical locations
M. Matsuura (2008)
10.1007/s10237-008-0128-z
Multi-axial mechanical properties of human trabecular bone
Liliana Rincón-Kohli (2009)
10.1148/radiol.10100222
Women with anorexia nervosa: finite element and trabecular structure analysis by using flat-panel volume CT.
C. Walsh (2010)
10.1016/S0021-9290(97)00123-1
Prediction of femoral fracture load using automated finite element modeling.
J. Keyak (1998)
10.1016/0021-9290(88)90008-5
On the dependence of the elasticity and strength of cancellous bone on apparent density.
J. Rice (1988)
10.1016/0021-9290(83)90072-6
A survey of finite element analysis in orthopedic biomechanics: the first decade.
R. Huiskes (1983)
10.1016/J.BONE.2007.08.039
Load distribution in the healthy and osteoporotic human proximal femur during a fall to the side.
E. Verhulp (2008)
10.1016/S0021-9290(03)00071-X
Trabecular bone modulus-density relationships depend on anatomic site.
E. Morgan (2003)
10.1016/S8756-3282(96)00383-3
Assessment of the strength of proximal femur in vitro: relationship to femoral bone mineral density and femoral geometry.
X. Cheng (1997)
10.1016/S0021-9290(08)70251-3
ANATOMY- AND MORPHOLOGY-BASED SMOOTH FINITE ELEMENT MODELS OF THE VERTEBRAL BODY
Yan Chevalier (2008)
10.1016/S0021-9290(03)00128-3
A review of morphology-elasticity relationships in human trabecular bone: theories and experiments.
P. Zysset (2003)
10.1016/S8756-3282(98)00164-1
Connectivity and the elastic properties of cancellous bone.
J. Kabel (1999)
10.2106/00004623-199503000-00008
Age-related reductions in the strength of the femur tested in a fall-loading configuration.
A. Courtney (1995)
10.1016/0021-9290(92)90062-6
On the relationship between the orthotropic Young's moduli and fabric.
S. Cowin (1992)
10.1007/s00256-009-0707-9
Reproducibility of trabecular structure analysis using flat-panel volume computed tomography
A. Cheung (2009)
10.1007/s00330-006-0156-y
Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization
R. Gupta (2006)
10.1007/S10853-006-0443-7
Wettability and spreading kinetics of molten aluminum on copper-coated ceramics
C. A. León (2006)
10.1016/0268-0890(93)90342-O
Mechanical failure in total hip arthroplasty with cement
R. Huiskes (1993)
10.1007/BF00540446
Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
T. Harrigan (1984)
10.1023/A:1007575322693
The Anisotropic Hooke's Law for Cancellous Bone and Wood
Guo-Yu Yang (1998)
10.1016/J.MEDENGPHY.2006.01.012
Estimating structural properties of trabecular bone from gray-level low-resolution images.
Z. Tabor (2007)
10.1016/j.jmbbm.2009.03.001
Mechanical evaluation by patient-specific finite element analyses demonstrates therapeutic effects for osteoporotic vertebrae.
Daisuke Tawara (2010)
10.1016/S8756-3282(97)00007-0
Three-dimensional methods for quantification of cancellous bone architecture.
A. Odgaard (1997)
10.1016/J.JBIOMECH.2005.07.018
Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy.
F. Taddei (2006)
10.1016/S8756-3282(01)00673-1
Mechanical consequence of trabecular bone loss and its treatment: a three-dimensional model simulation.
X. E. Guo (2002)
10.1016/J.JBIOMECH.2005.10.027
Comparison of micro-level and continuum-level voxel models of the proximal femur.
E. Verhulp (2006)
10.1016/0021-9290(88)90257-6
Limitations of the continuum assumption in cancellous bone.
T. Harrigan (1988)
10.1016/S0021-9290(00)00036-1
Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models.
H. Weinans (2000)
10.1148/radiol.2492080173
Distal radius in adolescent girls with anorexia nervosa: trabecular structure analysis with high-resolution flat-panel volume CT.
M. Bredella (2008)
10.1016/j.jbiomech.2011.03.024
Patient-specific finite element analysis of the human femur--a double-blinded biomechanical validation.
N. Trabelsi (2011)
10.1126/SCIENCE.996549
Bone compressive strength: the influence of density and strain rate.
D. Carter (1976)
10.1007/BF00310169
Effects of loading rate on strength of the proximal femur
A. Courtney (2004)
10.1359/jbmr.2003.18.10.1781
Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur
B. van Rietbergen (2003)
10.1016/j.clinbiomech.2008.11.003
Subject specific finite element analysis of stress shielding around a cementless femoral stem.
Sune H. Pettersen (2009)
10.1016/0167-6636(95)00018-6
An alternative model for anisotropic elasticity based on fabric tensors
P. Zysset (1995)
10.1016/0021-9290(94)90056-6
Predicting the compressive mechanical behavior of bone.
T. Keller (1994)
10.1016/S8756-3282(99)00190-8
Constitutive relationships of fabric, density, and elastic properties in cancellous bone architecture.
J. Kabel (1999)
10.1016/j.bone.2009.09.032
Biomechanical effects of teriparatide in women with osteoporosis treated previously with alendronate and risedronate: results from quantitative computed tomography-based finite element analysis of the vertebral body.
Y. Chevalier (2010)
10.1016/0021-9290(90)90048-8
The fabric dependence of the orthotropic elastic constants of cancellous bone.
C. Turner (1990)
10.1016/j.jbiomech.2008.11.028
A comparison of enhanced continuum FE with micro FE models of human vertebral bodies.
D. Pahr (2009)
10.1016/0141-5425(93)90066-8
Validation of an automated method of three-dimensional finite element modelling of bone.
J. Keyak (1993)
10.1016/0167-6636(85)90012-2
A symmetry invariant formulation of the relationship between the elasticity tensor and the fabric tensor.
M. Moesen (2012)
10.1002/JBM.820281111
Correlations between orthogonal mechanical properties and density of trabecular bone: use of different densitometric measures.
J. Keyak (1994)



This paper is referenced by
Algorithm for prediction of strains in human tibia by means of artificial intelligence techniques
Yosbel Angel Cisneros Hidalgo (2015)
10.1007/s10237-019-01225-2
Effect of fabric on the accuracy of computed tomography-based finite element analyses of the vertebra
Y. Wu (2019)
10.1016/j.jbiomech.2014.08.020
Mapping anisotropy of the proximal femur for enhanced image based finite element analysis.
W. S. Enns-Bray (2014)
10.1016/j.jbiomech.2016.07.031
Identification of elastic properties of human patellae using micro-finite element analysis.
A. Latypova (2016)
10.1063/1.4938990
Modeling of the mechanical behavior of the human femur: Stress analysis and strain
Dalila Belaid (2015)
10.1016/j.clinbiomech.2015.11.008
A patient-specific model of total knee arthroplasty to estimate patellar strain: A case study.
A. Latypova (2016)
10.1016/j.jbiomech.2013.06.035
Individual density-elasticity relationships improve accuracy of subject-specific finite element models of human femurs.
S. Eberle (2013)
10.1080/21681163.2013.869185
A finite element analysis of altered load distribution within femoral head in osteoarthritis
F. Marinozzi (2015)
10.1007/S40846-015-0061-4
Effects of Hip Osteoarthritis on Mechanical Stimulation of Trabecular Bone: a Finite Element Study
F. Marinozzi (2015)
10.1007/s00198-013-2591-3
Locally measured microstructural parameters are better associated with vertebral strength than whole bone density
J. Hazrati Marangalou (2013)
10.1007/978-3-319-99620-2_8
Application of Numerical Methods in Design and Analysis of Orthopedic Implant Integrity
Katarina Čolić (2018)
10.1016/j.medengphy.2016.08.010
Morphology based anisotropic finite element models of the proximal femur validated with experimental data.
W. Enns-Bray (2016)
10.1002/jbmr.1827
The heterogeneity in femoral neck structure and strength
M. Kersh (2013)
10.1177/0954406219856028
Analysis and validation of femur bone data using finite element method under static load condition
S. Mathukumar (2019)
Effect of biomaterial on integrity and life of artificial hip
Kaled Legweel (2016)
10.1108/RPJ-05-2017-0076
Heterogeneous topology design and voxel-based bio-printing
A. M. M. Nazmul Ahsan (2018)
10.1016/j.medengphy.2016.10.003
Importance of trabecular anisotropy in finite element predictions of patellar strain after Total Knee Arthroplasty.
A. Latypova (2017)
10.1016/j.bone.2020.115250
Finite element analysis of bone strength in osteogenesis imperfecta.
Péter Varga (2020)
10.1007/s10237-014-0584-6
A novel approach to estimate trabecular bone anisotropy from stress tensors
J. Hazrati Marangalou (2015)
10.2174/1874120701812010115
Comparative Study of Femur Bone Having Different Boundary Conditions and Bone Structure Using Finite Element Method
K. Chethan (2018)
10.1016/j.jbiomech.2013.07.042
A novel approach to estimate trabecular bone anisotropy using a database approach.
J. Hazrati Marangalou (2013)
Modelo mecanobiológico de una tibia humana para determinar su respuesta ante estímulos mecánicos externos
Yosbel Angel Cisneros Hidalgo (2015)
10.1016/j.promfg.2017.07.085
Direct Bio-printing with Heterogeneous Topology Design
A. N. Ahsan (2017)
10.1016/j.jbiomech.2013.07.004
Effect of boundary conditions, impact loading and hydraulic stiffening on femoral fracture strength.
I. Haider (2013)
10.1061/9780784412992.146
The Fabric Anisotropy Effect on Elastic and Yield behavior of the Human Calcaneus trabecular Bone
Mohammad F. Souzanchi (2013)
10.1016/j.jmbbm.2015.11.026
Nonlinear quasi-static finite element simulations predict in vitro strength of human proximal femora assessed in a dynamic sideways fall setup.
Péter Varga (2016)
10.1002/jor.23551
A novel in silico method to quantify primary stability of screws in trabecular bone
Juri A. Steiner (2017)
10.1016/j.jbiomech.2019.01.049
Scanner influence on the mechanical response of QCT-based finite element analysis of long bones.
Y. Katz (2019)
10.1016/j.jmbbm.2014.01.006
Orthotropic HR-pQCT-based FE models improve strength predictions for stance but not for side-way fall loading compared to isotropic QCT-based FE models of human femurs.
B. Luisier (2014)
10.1016/j.medengphy.2018.06.004
Mapping anisotropy improves QCT-based finite element estimation of hip strength in pooled stance and side-fall load configurations.
J. Panyasantisuk (2018)
10.1016/j.bone.2014.09.022
Predicting the stiffness and strength of human femurs with real metastatic tumors.
Z. Yosibash (2014)
10.1016/j.bone.2013.12.019
Inter-individual variability of bone density and morphology distribution in the proximal femur and T12 vertebra.
J. Hazrati Marangalou (2014)
See more
Semantic Scholar Logo Some data provided by SemanticScholar