Online citations, reference lists, and bibliographies.

Biomechanical Modeling To Improve Coronary Artery Bifurcation Stenting: Expert Review Document On Techniques And Clinical Implementation.

A. Antoniadis, P. Mortier, G. Kassab, G. Dubini, N. Foin, Y. Murasato, A. Giannopoulos, S. Tu, Kiyotaka Iwasaki, Y. Hikichi, F. Migliavacca, C. Chiastra, J. Wentzel, F. Gijsen, J. Reiber, P. Barlis, P. Serruys, Deepak L. Bhatt, G. Stanković, E. Edelman, G. Giannoglou, Y. Louvard, Y. Chatzizisis
Published 2015 · Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
Treatment of coronary bifurcation lesions remains an ongoing challenge for interventional cardiologists. Stenting of coronary bifurcations carries higher risk for in-stent restenosis, stent thrombosis, and recurrent clinical events. This review summarizes the current evidence regarding application and use of biomechanical modeling in the study of stent properties, local flow dynamics, and outcomes after percutaneous coronary interventions in bifurcation lesions. Biomechanical modeling of bifurcation stenting involves computational simulations and in vitro bench testing using subject-specific arterial geometries obtained from in vivo imaging. Biomechanical modeling has the potential to optimize stenting strategies and stent design, thereby reducing adverse outcomes. Large-scale clinical studies are needed to establish the translation of pre-clinical findings to the clinical arena.
This paper references
10.1161/01.ATV.8.4.410
Inhibition of Atherosclerosis Associated with Reduction of Arterial Intramural Stress in Rabbits
M. Thubrikar (1988)
Threedimensional modeling of double-stent techniques at the left main coronary artery bifurcation using micro-focus X-ray computed tomography. Catheter Cardiovasc Interv 2007;70:211–20
Y Murasato (2007)
10.4244/EIJV9I7A144
Tools & techniques clinical: optimising stenting strategy in bifurcation lesions with insights from in vitro bifurcation models.
N. Foin (2013)
10.1016/0021-9290(94)90209-7
Static circumferential tangential modulus of human atherosclerotic tissue.
H. Loree (1994)
10.1115/1.4006357
Finite Element Analysis of the Implantation of a Self-Expanding Stent: Impact of Lesion Calcification
Shijia Zhao (2012)
10.1152/ajpheart.00240.2011
Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.
H. Chen (2011)
Cardiology is fl ow
Y Richter (2006)
10.1007/s10439-009-9719-9
Hemodynamically Driven Stent Strut Design
J. M. Jiménez (2009)
10.1097/HCO.0b013e328331630b
The role of low endothelial shear stress in the conversion of atherosclerotic lesions from stable to unstable plaque
K. Koskinas (2009)
10.4244/EIJV9I1A7
Consensus from the 7th European Bifurcation Club meeting.
G. Stankovic (2013)
10.1253/CIRCJ.CJ-12-0272
Crush, culotte, T and protrusion: which 2-stent technique for treatment of true bifurcation lesions? - insights from in vitro experiments and micro-computed tomography.
N. Foin (2013)
10.4244/EIJV10I5A97
Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings.
J. Lassen (2014)
10.4244/EIJV7I5A96
Final proximal post-dilatation is necessary after kissing balloon in bifurcation stenting.
N. Foin (2011)
10.1161/CIRCINTERVENTIONS.113.000931
Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance: Implications for the Management of Incomplete Stent Apposition
N. Foin (2014)
10.1007/s10237-010-0196-8
Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning
D. Gastaldi (2010)
10.1161/CIRCULATIONAHA.110.003210
Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings
K. Kolandaivelu (2011)
10.1016/j.jcin.2013.03.012
Late thrombosis after double versus single drug-eluting stent in the treatment of coronary bifurcations: a meta-analysis of randomized and observational Studies.
M. Zimarino (2013)
10.1097/HCO.0b013e3283319b84
New advances in cardiac computed tomography
P. G. Ramkumar (2009)
10.1016/j.medengphy.2008.11.005
The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents.
Ian Owens Pericevic (2009)
10.1016/j.jconrel.2009.11.007
Lesion complexity determines arterial drug distribution after local drug delivery.
A. Tzafriri (2010)
10.1007/s10237-012-0432-5
Drug delivery patterns for different stenting techniques in coronary bifurcations: a comparative computational study
E. Cutri (2013)
10.3109/9781841847276-10
Bench Testing of Coronary Bifurcation Stenting Techniques: How Is It Done? Does It Help Technical Decision Making?
Y. Murasato (2010)
10.1016/j.atherosclerosis.2014.11.013
Is it safe to implant bioresorbable scaffolds in ostial side-branch lesions? Impact of 'neo-carina' formation on main-branch flow pattern. Longitudinal clinical observations.
A. Karanasos (2015)
10.1161/CIRCINTERVENTIONS.109.868091
Double Versus Single Stenting for Coronary Bifurcation Lesions: A Meta-Analysis
D. Katritsis (2009)
10.4244/EIJV11SVA8
Patient-specific computer modelling of coronary bifurcation stenting: the John Doe programme.
P. Mortier (2015)
10.1186/1475-925X-7-23
Simulation of stent deployment in a realistic human coronary artery
Frank JH Gijsen (2008)
10.1093/eurheartj/eht226
Geometrically correct three-dimensional optical coherence tomography: first self-expanding bifurcation stent evaluation.
A. Antoniadis (2013)
10.1016/j.atherosclerosis.2015.04.011
Accurate and reproducible reconstruction of coronary arteries and endothelial shear stress calculation using 3D OCT: comparative study to 3D IVUS and 3D QCA.
K. Toutouzas (2015)
10.4244/EIJV6SUPJA4
Flow and atherosclerosis in coronary bifurcations.
G. Giannoglou (2010)
10.1016/j.jacc.2010.01.021
Pathological findings at bifurcation lesions: the impact of flow distribution on atherosclerosis and arterial healing after stent implantation.
G. Nakazawa (2010)
10.1007/S13239-011-0047-5
Optical Coherence Tomography for Patient-specific 3D Artery Reconstruction and Evaluation of Wall Shear Stress in a Left Circumflex Coronary Artery
L. Ellwein (2011)
10.4244/EIJV9I12A242
Stent deformation, physical stress, and drug elution obtained with provisional stenting, conventional culotte and Tryton-based culotte to treat bifurcations: a virtual simulation study.
Stefano Morlacchi (2014)
10.4244/EIJV11SVA4
Impact of local flow haemodynamics on atherosclerosis in coronary artery bifurcations.
Antonios P. Antoniadis (2015)
10.1007/s10439-005-7598-2
Spatial Distribution of Platelet Deposition in Stented Arterial Models Under Physiologic Flow
Nandini Duraiswamy (2005)
10.4244/
Consensus from the 5th European Bifurcation Club meeting.
D. Hildick-Smith (2010)
10.1111/j.1540-8183.2010.00570.x
Recent perspective on coronary bifurcation intervention: statement of the "Bifurcation Club in KOKURA".
Yoshinobu Murasato (2010)
10.1016/J.EUROMECHFLU.2012.01.011
Computational fluid dynamics of stented coronary bifurcations studied with a hybrid discretization method
C. Chiastra (2012)
10.1016/j.jbiomech.2014.01.019
Mechanical properties of human atherosclerotic intima tissue.
A. Akyildiz (2014)
10.1115/1.1835362
Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.
G. Holzapfel (2005)
10.1007/s10439-012-0681-6
Modeling Stented Coronary Arteries: Where We are, Where to Go
Stefano Morlacchi (2012)
10.1172/JCI21007
Dynamic flow alterations dictate leukocyte adhesion and response to endovascular interventions.
Yoram Richter (2004)
10.1115/1.3118764
Comparison of near-wall hemodynamic parameters in stented artery models.
Nandini Duraiswamy (2009)
10.1080/10255842.2010.495066
Patient-specific computational haemodynamics: generation of structured and conformal hexahedral meshes from triangulated surfaces of vascular bifurcations
Gianluca De Santis (2011)
10.1007/978-3-642-23626-6_49
3D Modeling of Coronary Artery Bifurcations from CTA and Conventional Coronary Angiography
Rubén Cárdenes (2011)
10.4244/EIJV11SVA7
Virtual bench testing to study coronary bifurcation stenting.
F. Migliavacca (2015)
10.1016/S0002-9149(02)03100-4
Influence of residual stenosis after percutaneous coronary intervention with stent implantation on development of restenosis and stent thrombosis.
P. Sick (2003)
10.1016/j.jcin.2008.06.003
The "crush" technique for coronary artery bifurcation stenting: insights from micro-computed tomographic imaging of bench deployments.
J. Ormiston (2008)
10.1152/AJPHEART.01107.2004
Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries.
J. LaDisa (2005)
10.1007/s10554-011-9809-2
Fusion of 3D QCA and IVUS/OCT
S. Tu (2011)
10.1371/journal.pone.0021778
Expansion of the Multi-Link Frontier™ Coronary Bifurcation Stent: Micro-Computed Tomographic Assessment in Human Autopsy and Porcine Heart Samples
S. Kralev (2011)
Accurate and reproducible reconstruction of coronary arteries and endothelial shear stress calculation using 3D OCT: comparative study to 3D IVUS and3DQCA. Atherosclerosis 2015;240:510–9
K Toutouzas (2015)
10.1016/J.JACC.2007.02.059
Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling: molecular, cellular, and vascular behavior.
Y. Chatzizisis (2007)
10.1002/JBM.A.30023
Environmental influences on endovascular stent platelet reactivity: an in vitro comparison of stainless steel and gold surfaces.
K. Kolandaivelu (2004)
10.1115/SBC2008-192768
Analysis of Side Branch Access During Bifurcation Stenting
P. Mortier (2008)
10.1152/japplphysiol.91519.2008
Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis.
H. Chen (2009)
10.1016/j.medengphy.2013.01.007
Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases.
Stefano Morlacchi (2013)
10.1016/j.jcin.2013.09.012
Provisional stenting of coronary bifurcations: insights into final kissing balloon post-dilation and stent design by computational modeling.
P. Mortier (2014)
10.1161/CIRCINTERVENTIONS.108.846089
Drug-Eluting Stents in Bifurcations: Bench Study of Strut Deformation and Coating Lesions
P. Guérin (2010)
Computer modelling of coronary bifurcation stenting
Peter Mortier (2010)
10.1148/rg.2015140320
Medical 3D Printing for the Radiologist.
D. Mitsouras (2015)
10.1016/j.jacc.2011.10.903
Role of endothelial shear stress in stent restenosis and thrombosis: pathophysiologic mechanisms and implications for clinical translation.
K. Koskinas (2012)
10.4244/
Micro-computed tomographic assessment following extremely oversized partial postdilatation of drug-eluting stents.
M. Z. Basalus (2010)
10.1161/CIRCULATIONAHA.106.632687
Cardiology is flow.
Yoram Richter (2006)
10.1007/BF02368455
The effect of flow and mass transport in thrombogenesis
D. Basmadjian (1990)
10.1016/j.jacc.2009.11.052
Impact of stent overlap on angiographic and long-term clinical outcome in patients undergoing drug-eluting stent implantation.
L. Räber (2010)
10.1097/00019501-200609000-00007
In-vivo validation of spatially correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound and biplane angiography
G. Giannoglou (2006)
10.1016/j.jcin.2011.08.019
Kissing balloon or sequential dilation of the side branch and main vessel for provisional stenting of bifurcations: lessons from micro-computed tomography and computational simulations.
N. Foin (2012)
Drug-eluting stents for coronary bifurcations: bench testing of provisional side-branch strategies. Catheter Cardiovasc Interv 2006;67:49–55
JA Ormiston (2006)
10.1080/10255841003766845
Computational structural modelling of coronary stent deployment: a review
David Mingot Martín (2011)
10.1016/j.ijcard.2013.05.036
Location of side branch access critically affects results in bifurcation stenting: Insights from bench modeling and computational flow simulation.
N. Foin (2013)
10.4244/EIJV10I8A160
Optimal kissing balloon inflation after single-stent deployment in a coronary bifurcation model.
Y. Murasato (2014)
10.1111/j.1540-8183.2009.00436.x
Examination of stent deformation and gap formation after complex stenting of left main coronary artery bifurcations using microfocus computed tomography.
Y. Murasato (2009)
10.1007/s10439-010-0238-5
A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models
Timothy J. Gundert (2010)
10.1161/01.CIR.0000118474.71662.E3
Randomized Study to Evaluate Sirolimus-Eluting Stents Implanted at Coronary Bifurcation Lesions
A. Colombo (2004)
10.1115/1.4005476
Sequential structural and fluid dynamic numerical simulations of a stented bifurcated coronary artery.
Stefano Morlacchi (2011)
10.1002/ccd.21133
Three‐dimensional modeling of double‐stent techniques at the left main coronary artery bifurcation using micro‐focus X‐ray computed tomography
Y. Murasato (2007)
10.1161/CIRCINTERVENTIONS.112.000051
In vivo flow simulation at coronary bifurcation reconstructed by fusion of 3-dimensional X-ray angiography and optical coherence tomography.
S. Tu (2013)
10.1098/rsif.2013.0193
Computational fluid dynamic simulations of image-based stented coronary bifurcation models
C. Chiastra (2013)
10.1002/ccd.20453
Drug‐eluting stents for coronary bifurcations: Bench testing of provisional side‐branch strategies
J. Ormiston (2006)
domized study to evaluate sirolimus - eluting stents implanted at coronary bifurcation lesions
A Colombo (2004)
10.1016/j.jbiomech.2014.01.006
Predicting response to endovascular therapies: dissecting the roles of local lesion complexity, systemic comorbidity, and clinical uncertainty.
K. Kolandaivelu (2014)
10.4244/EIJV4I3A68
Comparison of drug-eluting stent cell size using micro-CT: important data for bifurcation stent selection.
P. Mortier (2008)
10.1146/ANNUREV.BIOENG.8.010506.105023
Biomechanical considerations in the design of graft: the homeostasis hypothesis.
G. Kassab (2006)
10.1002/(SICI)1522-726X(199906)47:2<258::AID-CCD27>3.0.CO;2-C
Stent deformation following simulated side‐branch dilatation: A comparison of five stent designs
J. Ormiston (1999)
10.1016/J.AMJCARD.2003.08.017
Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries.
F. Gijsen (2003)
10.1016/j.compbiomed.2010.02.005
Predicting neointimal hyperplasia in stented arteries using time-dependant computational fluid dynamics: A review
J. Murphy (2010)
10.1371/journal.pone.0086949
IVUS Validation of Patient Coronary Artery Lumen Area Obtained from CT Images
T. Luo (2014)
10.4244/EIJV8I2A34
Optical coherence tomography for guidance of distal cell recrossing in bifurcation stenting: choosing the right cell matters.
E. Alegría-Barrero (2012)



This paper is referenced by
10.1016/j.medengphy.2017.06.027
A framework for computational fluid dynamic analyses of patient-specific stented coronary arteries from optical coherence tomography images.
S. Migliori (2017)
10.1038/nrcardio.2016.170
Applications of 3D printing in cardiovascular diseases
A. Giannopoulos (2016)
10.1097/MCA.0000000000000847
Clinical outcome after percutaneous coronary intervention with drug-eluting stent in bifurcation and nonbifurcation lesions: a meta-analysis of 23 981 patients
F. Burzotta (2020)
10.1016/j.biomaterials.2019.119414
In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy.
Chenxin Chen (2019)
10.1016/j.atherosclerosis.2018.03.036
Understanding the role of non-coding RNA (ncRNA) in stent restenosis.
Shaoyan Liu (2018)
10.1002/9781118983652.CH16
Bifurcation Lesion Stenting
Y. Louvard (2016)
10.1007/s10237-017-0948-9
An in silico biomechanical analysis of the stent–esophagus interaction
Mathias Peirlinck (2018)
10.1016/j.jbiomech.2017.01.043
Effects of bifurcation-specific and conventional stents on coronary bifurcation flow. An experimental and numerical study.
Jorge García García (2017)
10.1080/17434440.2020.1733410
Histopathologic and physiologic effect of bifurcation stenting: current status and future prospects
A. Cornelissen (2020)
10.4244/EIJ-D-18-00357
Percutaneous coronary intervention in left main coronary artery disease: the 13th consensus document from the European Bifurcation Club.
F. Burzotta (2018)
10.3389/fphys.2018.00742
Application of Patient-Specific Computational Fluid Dynamics in Coronary and Intra-Cardiac Flow Simulations: Challenges and Opportunities
L. Zhong (2018)
10.1007/s13239-018-0359-9
Biomechanical Impact of Wrong Positioning of a Dedicated Stent for Coronary Bifurcations: A Virtual Bench Testing Study
Claudio Chiastra (2018)
10.4244/EIJ-D-17-00794
Characteristics of stent thrombosis in bifurcation lesions analysed by optical coherence tomography.
Mohamed Yahya Bechiri (2018)
Percutaneous coronary interventions of bifurcation lesions
Maik J Grundeken (2016)
10.4244/EIJV11I5A111
Reversal of flow between serial bifurcation lesions: insights from computational fluid dynamic analysis in a population-based phantom model.
P. Barlis (2015)
Modified Stent Design for a Coronary Bifurcation Lesion
Abigail Nowell (2020)
10.1016/j.jbiomech.2016.03.023
Microstructure-based biomechanics of coronary arteries in health and disease.
Huan Chen (2016)
10.1016/j.ijengsci.2019.103201
A review on the biomechanics of coronary arteries
H. J. Carpenter (2020)
10.1371/journal.pone.0157490
The Impact of the Geometric Characteristics on the Hemodynamics in the Stenotic Coronary Artery
Changnong Peng (2016)
10.1007/s11517-016-1574-x
Behaviour of two typical stents towards a new stent evolution
Mariana Simão (2016)
10.1101/2020.08.28.268599
Unraveling Endothelial Cell Phenotypic Regulation By Spatial Hemodynamic Flows With Microfluidics
Sarvesh Varma (2020)
10.1109/HIPCW.2018.8634225
Computational Fluid Modeling to Understand the Role of Anatomy in Bifurcation Lesion Disease
Madhurima Vardhan (2018)
10.1016/j.actbio.2019.03.025
Elucidating the role of graft compliance mismatch on intimal hyperplasia using an ex vivo organ culture model.
Allison Post (2019)
10.1016/j.compbiomed.2020.103623
A fully coupled computational fluid dynamics - agent-based model of atherosclerotic plaque development: Multiscale modeling framework and parameter sensitivity analysis
Anna Corti (2020)
10.1080/14779072.2018.1523717
Contemporary techniques in percutaneous coronary intervention for bifurcation lesions
Carlos A. Collet (2018)
POLITECNICO DI TORINO Repository ISTITUZIONALE A framework for computational fluid dynamic analyses of patient-specific stented coronary arteries from optical coherence tomography
Claudio Chiastra ()
10.1007/s13239-019-00431-4
Location-Specific Comparison Between a 3D In-Stent Restenosis Model and Micro-CT and Histology Data from Porcine In Vivo Experiments
P. Zun (2019)
10.1007/s10439-017-1806-8
Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling
G. Karanasiou (2017)
10.1007/978-3-030-35252-3_10
Computational Fluid Dynamics Simulations with Applications in Virtual Reality Aided Health Care Diagnostics
Vishwanath Panwar (2020)
10.4244/EIJ-D-17-00591
Impact of guidewire recrossing point into stent jailed side branch for optimal kissing balloon dilatation: core lab 3D optical coherence tomography analysis.
Takayuki Okamura (2018)
10.1002/ccd.27567
Differences in rotational positioning and subsequent distal main branch rewiring of the Tryton stent: An optical coherence tomography and computational study
M. Grundeken (2018)
10.1142/S0219519417400371
NUMERICAL ANALYSIS OF BALLOON EXPANDABLE STENT DEPLOYMENT INSIDE A PATIENT-SPECIFIC STENOTIC CORONARY ARTERY TO INVESTIGATE THE INSTANT MECHANICAL BEHAVIORS
Chuangye Xu (2017)
See more
Semantic Scholar Logo Some data provided by SemanticScholar