Liquid Calibration Phantoms In Ultra-Low-Dose QCT For The Assessment Of Bone Mineral Density.

Malakeh Malekzadeh, Shahrokh Abbasi-Rad, J. Keyak, Mahnaz Nabil, M. Asadi, Nazanin Mobini, Parisa Naghdi, H. Emadi, H. Saligheh Rad, M. Shiran
Published 2019 · Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
INTRODUCTION Cortical bone is affected by metabolic diseases. Some studies have shown that lower cortical bone mineral density (BMD) is related to increases in fracture risk which could be diagnosed by quantitative computed tomography (QCT). Nowadays, hybrid iterative reconstruction-based (HIR) computed tomography (CT) could be helpful to quantify the peripheral bone tissue. A key focus of this paper is to evaluate liquid calibration phantoms for BMD quantification in the tibia and under hybrid iterative reconstruction-based-CT with the different hydrogen dipotassium phosphate (K2HPO4) concentrations phantoms. METHODOLOGY Four ranges of concentrations of K2HPO4 were made and tested with 2 exposure settings. Accuracy of the phantoms with ash gravimetry and intermediate K2HPO4 concentration as hypothetical patients were evaluated. The correlations and mean differences between measured equivalent QCT BMD and ash density as a gold standard were calculated. Relative percentage error (RPE) in CT numbers of each concentration over a 6-mo period was reported. RESULTS The correlation values (R2 was close to 1.0), suggested that the precision of QCT-BMD measurements using standard and ultra-low dose settings were similar for all phantoms. The mean differences between QCT-BMD and the ash density for low concentrations (about 93 mg/cm3) were lower than high concentration phantoms with 135 and 234 mg/cm3 biases. In regard to accuracy test for hypothetical patient, RPE was up to 16.1% for the low concentration (LC) phantom for the case of high mineral content. However, the lowest RPE (0.4 to 1.8%) was obtained for the high concentration (HC) phantom, particularly for the high mineral content case. In addition, over 6 months, the K2HPO4 concentrations increased 25% for 50 mg/cm3 solution and 0.7 % for 1300 mg/cm3 solution in phantoms. CONCLUSION The excellent linear correlations between the QCT equivalent density and the ash density gold standard indicate that QCT can be used with submilisivert radiation dose. We conclude that using liquid calibration phantoms with a range of mineral content similar to that being measured will minimize bias. Finally, we suggest performing BMD measurements with ultra-low dose scan concurrent with iterative-based reconstruction to reduce radiation exposure.
This paper references
Understanding Bland Altman analysis. Biochemia Medica 25(2):141–151
D. Giavarina (2015)
10.1259/bjr.20130613
Using "iDose4" iterative reconstruction algorithm in adults' chest-abdomen-pelvis CT examinations: effect on image quality in relation to patient radiation exposure.
I. Arapakis (2014)
10.1037/1082-989X.12.4.399
Toward using confidence intervals to compare correlations.
G. Zou (2007)
Quantitative computed tomography (QCT) derived bone mineral density (BMD) in finite element studies: a review of the literature 2016
N Knowles (2016)
1994 Estimation of material properties in the equine metacarpus with use of quantitative computed tomography
TS Kaneko (2004)
10.1016/j.bone.2008.04.009
Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density.
A. Nazarian (2008)
Evaluation of public dose due to natural radiation of Gamma and Radon in Kashan city in Iran
Mnasoor Jafarizadeh (2014)
10.1016/S0001-2998(87)80024-7
Quantitative computed tomography in assessment of osteoporosis.
H. Genant (1987)
10.1016/j.jmir.2018.10.002
Design and Validation of Synchronous QCT Calibration Phantom: Practical Methodology.
Malakeh Malekzadeh (2019)
10.1148/radiol.10100047
Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.
Paul D Deak (2010)
mineral density
M Malekzadeh
10.1007/s10439-010-0196-y
Robust QCT/FEA Models of Proximal Femur Stiffness and Fracture Load During a Sideways Fall on the Hip
D. Dragomir-Daescu (2010)
10.1097/RCT.0b013e31821fee94
Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography
Y. Funama (2011)
10.1016/j.medengphy.2010.09.018
In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur.
A. Cong (2011)
10.1088/0031-9155/58/12/R63
Modelling the physics in the iterative reconstruction for transmission computed tomography.
J. Nuyts (2013)
10.1007/PL00006860
Bone densitometry in the clinical practice
R. Passariello (1997)
10.1186/s40634-016-0072-2
Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature
N. Knowles (2016)
10.1016/J.JBIOMECH.2003.08.010
Mechanical properties, density and quantitative CT scan data of trabecular bone with and without metastases.
T. S. Kaneko (2004)
10.1016/j.bone.2012.10.031
Age- and gender-related differences in cortical geometry and microstructure: Improved sensitivity by regional analysis.
G. Kazakia (2013)
10.1016/j.bone.2009.03.669
Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA).
K. Engelke (2009)
10.1002/JOR.1100120610
Estimation of material properties in the equine metacarpus with use of quantitative computed tomography
C. Les (1994)
10.1118/1.3480507
Improved accuracy of cortical bone mineralization measured by polychromatic microcomputed tomography using a novel high mineral density composite calibration phantom.
J. Deuerling (2010)
10.1007/BF01623175
Cross-calibration of liquid and solid QCT calibration standards: Corrections to the UCSF normative data
K. Faulkner (2005)
10.1007/BF00298748
Effect of decalcification on bone mineral content and bending strength of feline femur
K. Shah (2004)
10.1007/s00223-008-9158-x
Quantitative Assessment of Bone Tissue Mineralization with Polychromatic Micro-Computed Tomography
A. Burghardt (2008)
10.11613/BM.2015.015
Understanding Bland Altman analysis
D. Giavarina (2015)
10.1259/0007-1285-65-778-931
Single energy quantitative computed tomography: the effects of phantom calibration material and kVp on QCT bone densitometry.
R. Whitehouse (1992)
Quantita - tive micro - computed tomography : a non - invasive method to assess equivalent
A Nazarian (2008)
10.1016/j.medengphy.2012.08.022
An investigation to determine if a single validated density-elasticity relationship can be used for subject specific finite element analyses of human long bones.
S. Eberle (2013)
10.1016/j.bone.2009.12.015
Finite element analysis performed on radius and tibia HR-pQCT images and fragility fractures at all sites in postmenopausal women.
N. Vilayphiou (2010)
10.1037/0033-2909.87.2.245
Tests for comparing elements of a correlation matrix.
J. Steiger (1980)
10.1002/JBM.820281111
Correlations between orthogonal mechanical properties and density of trabecular bone: use of different densitometric measures.
J. Keyak (1994)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar