In many computational fluid dynamics (CFD) studies of stented vessel haemodynamics, the geometry of the stented vessel is described using non-deformed (NDF) geometrical models. These NDF models neglect complex physical features, such as stent and vessel deformation, which may have a major impact on the haemodynamic environment in stented coronary arteries. In this study, CFD analyses were carried out to simulate pulsatile flow conditions in both NDF and realistically-deformed (RDF) models of three stented coronary arteries. While the NDF models were completely idealised, the RDF models were obtained from nonlinear structural analyses and accounted for both stent and vessel deformation. Following the completion of the CFD analyses, major differences were observed in the time-averaged wall shear stress (TAWSS), time-averaged wall shear stress gradient (TAWSSG) and oscillatory shear index (OSI) distributions predicted on the luminal surface of the artery for the NDF and RDF models. Specifically, the inclusion of stent and vessel deformation in the CFD analyses resulted in a 32%, 30% and 31% increase in the area-weighted mean TAWSS, a 3%, 7% and 16% increase in the area-weighted mean TAWSSG and a 21%, 13% and 21% decrease in the area-weighted mean OSI for Stents A, B and C, respectively. These results suggest that stent and vessel deformation are likely to have a major impact on the haemodynamic environment in stented coronary arteries. In light of this observation, it is recommended that these features are considered in future CFD studies of stented vessel haemodynamics.
This paper references
10.1088/1748-6041/2/1/S05
Time-dependent 3D simulations of the hemodynamics in a stented coronary artery.
Isam Faik (2007)
10.1016/S0021-9290(00)00066-X
Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution.
J J Wentzel (2000)
10.1161/01.CIR.0000018282.32332.13
Images in cardiovascular medicine. Focal in-stent restenosis near step-up: roles of low and oscillating shear stress?
Attila Thury (2002)
10.1115/1.2194067
Developing pulsatile flow in a deployed coronary stent.
Divakar Rajamohan (2006)
10.1007/s10439-009-9836-5
A Novel Simulation Strategy for Stent Insertion and Deployment in Curved Coronary Bifurcations: Comparison of Three Drug-Eluting Stents
Peter Mortier (2009)
10.1016/1350-4533(95)00045-3
A focal stress gradient-dependent mass transfer mechanism for atherogenesis in branching arteries.
M Lei (1996)
10.1186/1475-925X-8-8
Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments
Juan David Mejìa (2009)
10.1016/S1885-5857(06)60044-3
[Influence of shear stress on in-stent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics].
Marcelo Sanmartín (2006)
Stent design properties and deployment ratio influence indexes of wall shear stress: Please cite this article in press
JF LaDisa (2014)
10.1007/s10439-005-2499-y
Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents
Taewon Seo (2005)
10.1152/ajpheart.01107.2004
Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries.
John F. LaDisa (2005)
10.1007/s10439-010-0238-5
A Rapid and Computationally Inexpensive Method to Virtually Implant Current and Next-Generation Stents into Subject-Specific Computational Fluid Dynamics Models
Timothy J. Gundert (2010)
10.1186/1475-925X-4-59
Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening
John F. LaDisa (2005)
10.1152/japplphysiol.00872.2004
Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models.
John F. LaDisa (2005)
10.1152/ajpheart.00934.2004
Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling.
Gerhard A. Holzapfel (2005)
10.1016/j.jmbbm.2014.02.009
On the necessity of modelling fluid-structure interaction for stented coronary arteries.
Claudio Chiastra (2014)
10.3233/BIR-2010-0568
A full-range, multi-variable, CFD-based methodology to identify abnormal near-wall hemodynamics in a stented coronary artery.
Jonathan Murphy (2010)
10.1115/1.3118764
Comparison of near-wall hemodynamic parameters in stented artery models.
Nandini Duraiswamy (2009)
10.1007/S13239-010-0028-0
A Numerical Methodology to Fully Elucidate the Altered Wall Shear Stress in a Stented Coronary Artery
Jonathan Murphy (2010)
Developed pulsatile flow in a deployed coronary stent.
Rupak Kumar Banerjee (2007)
10.1152/japplphysiol.00086.2010
Local hemodynamic changes caused by main branch stent implantation and subsequent virtual side branch balloon angioplasty in a representative coronary bifurcation.
Andrew Robert Williams (2010)
10.1161/01.CIR.0000066914.95878.6D
Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent Implantation: Inhibition Through Reduction of Inflammation?
Stephane G. Carlier (2003)
10.1114/1.1588654
Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation
John F. LaDisa (2004)
10.1002/cnm.2557
Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
David Moral Martín (2013)
10.1114/1.1569268
The Stress–Strain Behavior of Coronary Stent Struts is Size Dependent
Bryan Patrick Murphy (2003)
10.1115/1.4005542
Optimization of cardiovascular stent design using computational fluid dynamics.
Timothy J. Gundert (2012)
10.1098/rsif.2013.0193
Computational fluid dynamic simulations of image-based stented coronary bifurcation models
Claudio Chiastra (2013)
10.1152/japplphysiol.01329.2003
Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery.
John F. LaDisa (2004)
10.1007/s10439-010-9962-0
The Influence of Strut-Connectors in Stented Vessels: A Comparison of Pulsatile Flow Through Five Coronary Stents
Sanjay Pant (2010)
10.1152/japplphysiol.91519.2008
Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis.
Henry Y. Chen (2009)
10.1098/rsif.2011.0675
Impact of main branch stenting on endothelial shear stress: role of side branch diameter, angle and lesion
Henry Y. Chen (2011)
10.1157/13083645
Influencia de la tensión de cizallamiento en la reestenosis intra-stent: estudio in vivo con reconstrucción 3D y dinámica de fluidos computacional
Marcelo Sanmartín (2006)
10.1016/j.jbiomech.2013.10.048
Hemodynamics in coronary arteries with overlapping stents.
Farhad Rikhtegar (2014)
10.1161/01.CIR.103.13.1740
Relationship Between Neointimal Thickness and Shear Stress After Wallstent Implantation in Human Coronary Arteries
J J Wentzel (2001)
10.1016/J.JMATPROTEC.2007.06.010
Analysis of wall shear stress in stented coronary artery using 3D computational fluid dynamics modeling
Vahab Dehlaghi (2008)
10.1115/1.1934122
Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions.
Yong Nian He (2005)
Focal in-stent restenosis near step-up: roles of low and oscillating shear stress? Circulation 2002;105:185e–7e
A. Thury (2002)
10.1371/journal.pone.0058147
Compound Ex Vivo and In Silico Method for Hemodynamic Analysis of Stented Arteries
Farhad Rikhtegar (2013)
Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery
Hun Jung (2004)
10.1186/1475-925X-5-40
Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling
John F. LaDisa (2006)
10.1016/j.jbiomech.2007.12.005
Effects of different stent designs on local hemodynamics in stented arteries.
Rossella Balossino (2008)
10.1007/S13239-011-0047-5
Optical Coherence Tomography for Patient-specific 3D Artery Reconstruction and Evaluation of Wall Shear Stress in a Left Circumflex Coronary Artery
Laura Ellwein (2011)
10.1016/J.EUROMECHFLU.2012.01.011
Computational fluid dynamics of stented coronary bifurcations studied with a hybrid discretization method
Claudio Chiastra (2012)
10.3844/AJASSP.2008.340.346
Effect of Stent Geometry on Phase Shift between Pressure and Flow Waveforms in Stented Human Coronary Artery
Vahab Dehlaghi (2008)



This paper is referenced by
10.3389/fbioe.2019.00366
Structural and Hemodynamic Analyses of Different Stent Structures in Curved and Stenotic Coronary Artery
Lingling Wei (2019)
10.21427/D7X75W
Oxygen Transport in Carotid and Stented Coronary Arteries
Eoin A Murphy (2017)
10.1080/10407782.2017.1293976
Three-dimensional numerical simulation of a failed coronary stent implant at different degrees of residual stenosis. Part II: Apparent viscosity and wall permeability
Andrea Boghi (2017)
10.1016/j.mvr.2018.03.001
Influence of microvascular sutures on shear strain rate in realistic pulsatile flow.
R. Wain (2018)
10.1007/S12046-018-0883-1
Numerical investigation of influence of number of stent cells and type of link on expansion and haemodynamic behaviour of balloon-expandable coronary stent
Chandrakantha Bekal (2018)
10.1115/1.4040400
Sensitivity of Arterial Hyperelastic Models to Uncertainties in Stress-Free Measurements.
Nir Emuna (2018)
10.1016/j.jbiomech.2015.11.024
Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses.
Claudio Chiastra (2016)
10.1016/j.jmbbm.2018.07.020
Fluid-structure interaction (FSI) analysis of stent-graft for aortic endovascular aneurysm repair (EVAR): Material and structural considerations.
Raja Jayendiran (2018)
10.1002/cnm.3247
Computational Modelling of Magnesium Stent Mechanical Performance in a Remodelling Artery: Effects of Multiple Remodelling Stimuli.
Enda L Boland (2019)
10.1016/j.ijmecsci.2020.105664
Evaluation of stent-graft implantations for intramural hematoma based on fluid-solid interaction analysis
Xuelan Zhang (2020)
The Influence of Stent Geometry on Haemodynamics and Endothelialisation
Luke Boldock (2017)
10.3389/fphys.2017.00226
Patient-Specific, Multi-Scale Modeling of Neointimal Hyperplasia in Vein Grafts
Francesca Donadoni (2017)
10.1102/2051-7726.2017.0001
Computational fluid dynamics in complex aortic surgery: applications, prospects and challenges
Fan Shuen Tseng (2017)
10.1080/10255842.2017.1289374
Computational fluid dynamics study of common stent models inside idealised curved coronary arteries
Winson X Chen (2017)
In vitro characterisation of stent deployment and local arterial strains
Iwona Zwierzak (2014)
10.1016/j.jbiomech.2016.03.038
Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.
Susann Beier (2016)
10.1016/B978-0-12-811018-8.00009-6
Vascular Hemodynamics with Computational Modeling and Experimental Studies
Susann Beier (2017)
10.1007/s10439-015-1501-6
Oxygen Mass Transport in Stented Coronary Arteries
Eoin A Murphy (2015)
10.1007/s13239-015-0219-9
Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis
David Martín (2015)
10.1142/S0219519417400371
NUMERICAL ANALYSIS OF BALLOON EXPANDABLE STENT DEPLOYMENT INSIDE A PATIENT-SPECIFIC STENOTIC CORONARY ARTERY TO INVESTIGATE THE INSTANT MECHANICAL BEHAVIORS
Chuangye Xu (2017)
10.30880/IJIE.2019.11.01.024
Evaluation System on Haemodynamic Parameters for Stented Carotid Artery: Stent Pictorial Selection Method
Muhammad Sufyan Amir Paisal (2019)
10.1080/10407782.2017.1293985
Three-dimensional numerical simulation of a failed coronary stent implant at different degrees of residual stenosis. Part I: Fluid dynamics and shear stress on the vascular wall
Ivan Di Venuta (2017)
Patient-specific blood flow modelling in diagnosis of coronary artery disease
Alena Uus (2016)
10.1007/s10439-015-1387-3
Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations
Susann Beier (2015)
10.1515/bmt-2017-0101
Impact of strut dimensions and vessel caliber on thrombosis risk of bioresorbable scaffolds using hemodynamic metrics
Michael Stiehm (2019)
Semantic Scholar Logo Some data provided by SemanticScholar