Gamma ray transmission measurements have been used to evaluate the water equivalence of solid phantoms. Technetium-99m was used in narrow beam geometry and the transmission of photons measured, using a gamma camera, through varying thickness of the solid phantom material and water. Measured transmission values were compared with Monte Carlo calculated transmission data using the EGSnrc Monte Carlo code to score fluence in a geometry similar to that of the measurements. The results indicate that the RMI457 Solid Water, CMNC Plastic Water and PTW RW3 solid phantoms had similar transmission values as compared to water to within ±1.5%. However, Perspex had a greater deviation in the transmission values up to ±4%. The agreement between the measured and EGSnrc calculated transmission values agreed to within ±1% over the range of phantom thickness studied. The linear attenuation coefficients at the gamma ray energy of 140.5 keV were determined from the measured and EGSnrc calculated transmission data and compared with predicted values derived from data provided by the National Institute of Standards and Technology (NIST) using the XCOM program. The coefficients derived from the measured data were up to 6% lower than those predicted by the XCOM program, while the coefficients determined from the Monte Carlo calculations were between measured and XCOM values. The results indicate that a similar process can be followed to determine the water equivalency of other solid phantoms and at other photon energies.



This paper is referenced by
10.1107/S1600577517005641
Comparison of phantom materials for use in quality assurance of microbeam radiation therapy.
Matthew Cameron (2017)
10.1088/1742-6596/847/1/012014
Water equivalence study of metal impregnated PAGAT gel dosimeter in terms of variation of effective atomic number
P. Sathiyaraj (2017)
10.24203/AJAS.V7I4.5901
Characterization of Low-Cost Materials as Human Tissue Equivalent Materials
Amirah Afiqah Bakri (2019)
10.1007/s13246-018-0692-1
Australasian recommendations for quality assurance in kilovoltage radiation therapy from the Kilovoltage Dosimetry Working Group of the Australasian College of Physical Scientists and Engineers in Medicine
Robin D. Hill (2018)
10.1017/S1460396917000450
Dosimetric characterisation of anthropomorphic PRESAGE® dosimeter and EBT2 film for partial breast radiotherapy
Khalid Javed Iqbal (2017)
10.4236/OJRAD.2014.41006
Biological Tissue Modeling with Agar Gel Phantom for Radiation Dosimetry of 99m Tc
Liliana Aranda-Lara (2014)
10.1016/j.apradiso.2019.108919
Characterization of Nylon-12 as a water-equivalent solid phantom material for dosimetric measurements in therapeutic photon and electron beams.
Nicholas Ade (2019)
10.1118/1.4867858
Influence of polarization and a source model for dose calculation in MRT.
Stefan Bartzsch (2014)
10.12693/APHYSPOLA.131.1032
Monte Carlo Calculations for Photon Attenuation Studies on Different Solid Phantom Materials
Ozcan Gundogdu (2017)
10.1118/1.4802731
Determination of transit dose profile for a (192)Ir HDR source.
Gabriel Paiva Fonseca (2013)
Improvements to the dosimetry of 106Ru/106Rh ophthalmic plaques: Monte Carlo simulations and radiochromic film measurements
Marcelino Hermida López (2017)
10.1016/J.RADPHYSCHEM.2019.03.021
X-ray spectrometry applied for determination of linear attenuation coefficient of tissue-equivalent materials
Audrew Frimaio (2019)
10.1088/1742-6596/777/1/012015
Monte Carlo characterisation of the Dose Magnifying Glass for proton therapy quality assurance
Arpit Merchant (2017)
10.1016/J.RADPHYSCHEM.2012.03.019
The energy spectrum of 662 keV photons in a water equivalent phantom
Urkiye Akar Tarim (2012)
10.24294/irr.v0i0.593
Mass attenuation coefficients of several water equivalent phantom materials by using Compton scattering technique in comparison to the theoretical XCOM values
Mohd Fahmi Mohd Yusof (2018)
10.1007/s00066-014-0713-2
Surface dose characterisation of the Varian Ir-192 HDR conical surface applicator set with a vertically orientated source
Konrad Buchauer (2014)
10.1088/1742-6596/847/1/012039
Dosimetric validation study of a flattening filter free SABR treatment by use of a normoxic PAG gel dosimeter with MRI readout
Anthony Venning (2017)
10.1118/1.4922001
Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy.
Stefan Bartzsch (2015)
10.1007/s13246-018-0673-4
Characterisation of radiological properties of a brachytherapy moulding material
Scott B. Crowe (2018)
10.1080/09500340.2012.700329
Estimation of the complex refractive index of epoxy resin phantom using EDTRM
Jin Wang (2012)
Modelado de tejido biológico con maniquí de gel de agar para dosimetría del 99m Tc
Estado de México (2013)
10.1007/BF03178644
Abstracts of the kV09 conference
D. Andrew Wilkinson (2009)
10.1088/1742-6596/777/1/012029
Review of gel dosimetry: a personal reflection
Clive Baldock (2016)
10.1088/1742-6596/851/1/012021
Homogeneous and inhomogeneous material effect in gamma index evaluation of IMRT technique based on fan beam and Cone Beam CT patient images
Wahyu Wibowo (2017)
10.1088/0031-9155/56/15/004
Radiological characterization and water equivalency of genipin gel for x-ray and electron beam dosimetry.
T. Gorjiara (2011)
10.1016/J.RADPHYSCHEM.2018.12.010
Investigation of the radiological properties of various phantoms for their application in low energy X-rays dosimetry
Roghayeh Kargar Shaker Langaroodi (2019)
10.1093/rpd/nct315
Skin dose measurements using radiochromic films, TLDS and ionisation chamber and comparison with Monte Carlo simulation.
Saleh Alashrah (2014)
10.1007/BF03178607
Abstracts of the EPSM-ABEC 2008 conference
David J. Franich (2009)
10.2174/1874471011666180914095222
Determination of Gamma Camera's Calibration Factors for Quantitation of Diagnostic Radionuclides in Simultaneous Scattering and Attenuation Correction.
Afrouz Asgari (2019)
10.1080/16878507.2019.1708576
Analysis of water-equivalent materials used during irradiation in the clinic with XCOM and BEAMnrc
Taylan Tuğrul (2019)
10.1118/1.3462558
The water equivalence of solid phantoms for low energy photon beams.
Robin D. Hill (2010)
10.1016/j.measurement.2019.107210
Investigations of radiation properties, photon interaction parameters and water equivalence of some polymers used in the construction of ionization chambers for low energy X-ray beams
Seyed Milad Vahabi (2020)
See more
Semantic Scholar Logo Some data provided by SemanticScholar