Online citations, reference lists, and bibliographies.
Please confirm you are human
(Sign Up for free to never see this)
← Back to Search

Increased Sensitivity In Proton Transfer Reaction Mass Spectrometry By Incorporation Of A Radio Frequency Ion Funnel.

S. Barber, R. S. Blake, I. R. White, P. Monks, F. Reich, S. Mullock, A. Ellis
Published 2012 · Chemistry, Medicine

Save to my Library
Download PDF
Analyze on Scholarcy
Share
A drift tube capable of simultaneously functioning as an ion funnel is demonstrated in proton transfer reaction mass spectrometry (PTR-MS) for the first time. The ion funnel enables a much higher proportion of ions to exit the drift tube and enter the mass spectrometer than would otherwise be the case. An increase in the detection sensitivity for volatile organic compounds of between 1 and 2 orders of magnitude is delivered, as demonstrated using several compounds. Other aspects of analytical performance explored in this study include the effective E/N (ratio of electric field to number density of the gas) and dynamic range over which the drift tube is operated. The dual-purpose drift tube/ion funnel can be coupled to various types of mass spectrometers to increase the detection sensitivity and may therefore offer considerable benefits in PTR-MS work.
This paper references
10.1016/S1387-3806(00)00265-7
Simulation-based optimization of the electrodynamic ion funnel for high sensitivity electrospray ionization mass spectrometry
A. Tolmachev (2000)
10.1016/J.IJMS.2005.09.008
A hollow cathode proton transfer reaction time of flight mass spectrometer
C. Ennis (2005)
10.1016/J.IJMS.2009.07.005
A high resolution and high sensitivity proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS)
A. Jordan (2009)
10.1021/ac801328d
Development of a proton-transfer reaction-linear ion trap mass spectrometer for quantitative determination of volatile organic compounds.
L. Mielke (2008)
10.1021/AC991412X
Design and implementation of a new electrodynamic ion funnel.
T. Kim (2000)
10.1002/MAS.20119
Measurements of volatile organic compounds in the earth's atmosphere using proton-transfer-reaction mass spectrometry.
J. D. de Gouw (2007)
10.1016/J.JASMS.2005.03.025
Development of proton-transfer ion trap-mass spectrometry: on-line detection and identification of volatile organic compounds in air
C. Warneke (2005)
10.1021/AC0498260
Demonstration of proton-transfer reaction time-of-flight mass spectrometry for real-time analysis of trace volatile organic compounds.
R. S. Blake (2004)
10.1016/0168-1176(95)04294-U
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
A. Hansel (1995)
10.1016/S0168-1176(97)00281-4
On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research
W. Lindinger (1998)
10.1016/J.JASMS.2007.03.031
Ion mobility spectrometry—mass spectrometry performance using electrodynamic ion funnels and elevated drift gas pressures
E. Baker (2007)
10.1016/J.IJMS.2007.01.009
Development of a PTR-TOFMS instrument for real-time measurements of volatile organic compounds in air
H. Tanimoto (2007)
10.1016/J.IJMS.2006.09.031
Development of a proton-transfer reaction ion trap mass spectrometer
M. Steeghs (2007)
10.1021/AC990346W
Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry.
S. Shaffer (1999)
10.1002/1097-0231(20001130)14:22<2129::AID-RCM144>3.0.CO;2-M
Characterizing the transmission properties of an ion funnel.
E. Lynn (2000)
10.1002/mas.20232
The ion funnel: theory, implementations, and applications.
R. Kelly (2010)
10.1039/A827347Z
Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels
W. Lindinger (1998)
10.1021/cr800364q
Proton-transfer reaction mass spectrometry.
R. S. Blake (2009)
10.1002/(SICI)1097-0231(19971030)11:16<1813::AID-RCM87>3.0.CO;2-D
A novel ion funnel for focusing ions at elevated pressure using electrospray ionization mass spectrometry
S. Shaffer (1997)
10.1016/J.IJMS.2007.02.011
Collision induced dissociation study of 10 monoterpenes for identification in trace gas measurements using the newly developed proton-transfer reaction ion trap mass spectrometer
M. Steeghs (2007)
10.1002/RCM.1088
Proton transfer reaction ion trap mass spectrometer.
P. Prazeller (2003)
10.1039/B204712H
The application of proton transfer reaction-mass spectrometry (PTR-MS) to the monitoring and analysis of volatile organic compounds in the atmosphere.
C. Hewitt (2003)
10.1016/J.JASMS.2005.06.012
Ion funnels for the masses: Experiments and simulations with a simplified ion funnel
R. Julian (2005)
10.1016/J.JASMS.2006.06.005
Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface
Y. Ibrahim (2006)



This paper is referenced by
10.1021/BK-2015-1191.CH017
Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOFMS) for Aroma Compound Detection in Real-Time: Technology, Developments, and Applications
J. Beauchamp (2015)
10.1007/s00216-020-02846-8
Effects of modular ion-funnel technology onto analysis of breath VOCs by means of real-time mass spectrometry
Giovanni Pugliese (2020)
10.18174/522719
Show me its volatile profile and I will tell you its quality : rapid fingerprinting of food volatilome at the boundary between food industry and sensory perception
Michele Pedrotti (2020)
10.1080/10739149.2019.1579100
V-shaped ion funnel proton transfer reaction mass spectrometry
Yujie Wang (2019)
10.1007/s11306-014-0692-4
Metabolite profiling of Clostridium difficile ribotypes using small molecular weight volatile organic compounds
S. Kuppusami (2014)
Novel approaches to the measurement of complex atmospheric VOC mixtures using proton transfer reaction mass spectrometry
Daniel John Blenkhorn (2019)
10.1016/j.talanta.2019.120468
Development of microwave plasma proton transfer reaction mass spectrometry (MWP-PTR-MS) for on-line monitoring of volatile organic compounds: Design, characterization and performance evaluation.
Zhongjun Zhao (2020)
10.1016/J.IJMS.2015.05.003
Development and use of a thermal desorption unit and proton transfer reaction mass spectrometry for trace explosive detection: Determination of the instrumental limits of detection and an investigation of memory effects
Ramón González-Méndez (2015)
10.1016/J.IJMS.2018.07.002
A simple centripetal force model for explaining the focusing effect of ion funnels
M. Allers (2018)
Etude en atmosphère simulée de la formation d'Aérosol Organique Secondaire issue de la photooxydation du n-dodécane : impact des paramètres environnementaux
H. Lamkaddam (2017)
10.1007/s00216-019-01807-0
Ultra-high-resolution ion mobility spectrometry—current instrumentation, limitations, and future developments
A. Kirk (2019)
10.1021/acs.est.6b03821
High-NOx Photooxidation of n-Dodecane: Temperature Dependence of SOA Formation.
H. Lamkaddam (2017)
Development and use of a thermal desorption unit and proton transfer reaction mass spectrometry for trace explosive detection
G. Méndez (2015)
10.1021/acs.analchem.6b01707
High-Pressure Photon Ionization Source for TOFMS and Its Application for Online Breath Analysis.
Yan Wang (2016)
Nitrosothiols as a cancer marker
Wolfgang Schröder (2013)
10.3791/54075
PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis.
V. Capozzi (2017)
10.1021/ACS.ANALCHEM.6B02982
Enhancement of Compound Selectivity Using a Radio Frequency Ion-Funnel Proton Transfer Reaction Mass Spectrometer: Improved Specificity for Explosive Compounds.
Ramón González-Méndez (2016)
10.1016/J.IJMS.2017.01.001
Implementation and characterization of an RF ion funnel ion guide as a proton transfer reaction chamber
Phil A. Brown (2017)
10.1088/1752-7155/8/2/027101
Mass spectrometry for real-time quantitative breath analysis.
D. Smith (2014)
10.5194/AMT-10-1445-2017
Measurement of alkyl and multifunctional organic nitrates by proton-transfer-reaction mass spectrometry
M. Duncianu (2016)
10.1021/acs.chemrev.7b00325
Proton-Transfer-Reaction Mass Spectrometry: Applications in Atmospheric Sciences.
B. Yuan (2017)
10.1016/J.IJMS.2014.05.004
A Proton Transfer Reaction-Quadrupole interface Time-Of-Flight Mass Spectrometer (PTR-QiTOF): High speed due to extreme sensitivity
Philipp Sulzer (2014)
What effect does VOC sampling time have on derived OH 1 reactivity ? 2 3
H. Sonderfeld (2016)
Improving PTR-ToF-MS: implementation of a radio frequency ion funnel and an investigation into buffer-gas doping
S. Barber (2015)
10.1016/S1872-2040(18)61133-8
Research Progress and Application of Ion Funnel Technique
T. Guo (2019)
10.1016/j.aca.2018.06.056
PTR-MS and GC-MS as complementary techniques for analysis of volatiles: A tutorial review.
T. Majchrzak (2018)
10.1088/1752-7155/7/2/026002
Near real-time VOCs analysis using an aspiration ion mobility spectrometer.
P. Mochalski (2013)
10.1016/S1872-2040(18)61101-6
Development of a SIMION-Simulated Ion Funnel Tube for Proton Transfer Reaction Mass Spectrometry
H. Zhu (2018)
10.1007/s13361-019-02241-3
A Simple Printed Circuit Board–Based Ion Funnel for Focusing Low m/z Ratio Ions with High Kinetic Energies at Elevated Pressure
Florian Schlottmann (2019)
10.5194/ACP-16-6303-2016
What effect does VOC sampling time have on derived OH reactivity
H. Sonderfeld (2016)
Interactive comment on “ What effect does VOC sampling time have on derived OH reactivity ? ” by
H. Sonderfeld (2016)
Metabolite Profiling of Biological Specimens Using Small Molecular Weight Volatile Organic Compounds by Proton Transfer Reaction Time-of-Flight Mass Spectrometry
S. Kuppusami (2017)
See more
Semantic Scholar Logo Some data provided by SemanticScholar