Assessment Of The Effect Of Mesh Density On The Material Property Discretisation Within QCT Based FE Models: A Practical Example Using The Implanted Proximal Tibia

A. Perillo-Marcone, A. Alonso-Vázquez, M. Taylor
Published 2003 · Engineering, Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
A three-dimensional, quantitative computed tomography based finite element model of a proximal implanted tibia was analysed in order to assess the effect of mesh density on material property discretisation and the resulting influence on the predicted stress distribution. The mesh was refined on the contact surfaces (matched meshes) with element sizes of 3, 2, 1.4, 1 and 0.8 mm. The same loading conditions were used in all models (bi-condylar load: 60% medial, 40% lateral). Significant variations were observed in the modulus distributions between the coarsest and finest mesh densities. Poor discretisation of the material properties also resulted in poor correlations of the stresses and risk ratios between the coarsest and finest meshes. Little difference in Young's modulus, von Mises stress and risk ratio distributions were observed between the three finest models; hence, it was concluded that for this particular case an element size of 1.4 mm on the contact surfaces was enough to properly describe the stiffness, stress and risk ratio distributions within the bone. Poor convergence of the material property distribution occurred when the element size was significantly larger than the pixel size of the source CT data. It was concluded that unless there is convergence in the Young's modulus distribution, convergence of the stress field or of other parameters of interest will not occur either.
This paper references
10.1002/JOR.1100090315
Estimation of mechanical properties of cortical bone by computed tomography
S. Snyder (1991)
10.1016/S0021-9290(98)00150-X
Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions.
B. van Rietbergen (1999)
10.1016/0021-9290(89)90073-0
Anatomical variation of orthotropic elastic moduli of the proximal human tibia.
R. B. Ashman (1989)
10.2106/00004623-197759070-00021
The compressive behavior of bone as a two-phase porous structure.
D. Carter (1977)
10.1016/0021-9290(88)90257-6
Limitations of the continuum assumption in cancellous bone.
T. Harrigan (1988)
10.1243/0954411011533562
A comparison between automatically generated linear and parabolic tetrahedra when used to mesh a human femur
K. Polgár (2001)
10.1016/S1350-4533(98)00081-2
Material properties assignment to finite element models of bone structures: a new method.
C. Zannoni (1998)
10.1016/0021-9290(90)90009-R
Three-axial strain controlled testing applied to bone specimens from the proximal tibial epiphysis.
F. Linde (1990)
10.1016/0021-9290(70)90050-3
The mechanics of the knee joint in relation to normal walking.
J. Morrison (1970)
10.1243/0954411011533760
A three-dimensional finite element model from computed tomography data: A semi-automated method
P. M. Cattaneo (2001)
10.1016/8756-3282(89)90074-4
Sex differences in age-related loss of vertebral trabecular bone mass and structure--biomechanical consequences.
L. Mosekilde (1989)
10.1016/S0021-9290(00)00036-1
Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models.
H. Weinans (2000)
10.1016/0021-9290(83)90097-0
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location.
S. Goldstein (1983)
10.1016/0021-9290(91)90305-7
Mechanical properties of trabecular bone. Dependency on strain rate.
F. Linde (1991)
10.1016/0141-5425(92)90100-Y
Three-dimensional finite element modelling of bone: effects of element size.
J. Keyak (1992)
10.2106/00004623-198567080-00010
Prediction of vertebral body compressive fracture using quantitative computed tomography.
R. Mcbroom (1985)
10.1016/0141-5425(93)90061-3
The use of strain energy as a convergence criterion in the finite element modelling of bone and the effect of model geometry on stress convergence.
L. Marks (1993)
10.1016/S0021-9290(99)00141-4
Improving the local solution accuracy of large-scale digital image-based finite element analyses.
G. Charras (2000)
10.1097/00003086-198910000-00029
Stiffness of bone underlying the tibial plateaus of osteoarthritic and normal knees.
J. Finlay (1989)



This paper is referenced by
Image-based Finite Element Analysis of Head Injuries and Helmet Design
Zhaoyang Liang (2012)
A qualitative approach for medial computation
J. Michael ()
10.1016/b978-1-4377-1503-3.00017-2
Does Strain in the Patella Change After TKA?: A Finite Element Investigation of Natural and Implanted Patellae
Clare K Fitzpatrick (2012)
10.1243/09544119JEIM739
A review of probabilistic analysis in orthopaedic biomechanics
P. Laz (2010)
10.1080/10255842.2011.564163
A numerically validated probabilistic model of a simplified total hip replacement construct
L. Mehrez (2012)
10.1016/j.medengphy.2009.10.008
Statistical modelling of the whole human femur incorporating geometric and material properties.
R. Bryan (2010)
10.1111/J.1475-1305.2008.00500.X
A Method to Improve Experimental Validation of Finite-Element Models of Long Bones
M. Juszczyk (2008)
10.1097/BOT.0b013e31825d60cb
Biomechanical Effects of the Nail Entry Zone and Anterior Cortical Bone Loss on the Proximal Tibia
H. Mir (2013)
10.1016/J.BONE.2004.11.007
Prediction of fracture callus mechanical properties using micro-CT images and voxel-based finite element analysis.
S. Shefelbine (2005)
10.1016/j.bone.2010.11.010
Subchondral cysts create increased intra-osseous stress in early knee OA: A finite element analysis using simulated lesions.
D. McErlain (2011)
10.1007/8415_2010_32
Biomechanical modelling of cells in mechanoregulation
A. Lennon (2010)
10.1115/1.2913335
Experimental validation of a finite element model of a human cadaveric tibia.
H. Gray (2008)
10.1016/J.MEDENGPHY.2007.05.006
A modified method for assigning material properties to FE models of bones.
B. Helgason (2008)
10.1007/S10409-019-00855-0
Single-leg weight limit of fixation model of simple supracondylar fracture of femur
Guo-Yu Bai (2019)
10.1080/17452759.2012.755654
Patient specific parametric geometric modelling and finite element analysis of cementless hip prosthesis
Subin Philip George (2013)
Metodología para incorporar propiedades de tejido óseo no isotrópico a un modelo de elementos finitos
T. S. Antonio (2008)
10.1115/1.2401177
Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study.
A. Perillo-Marcone (2007)
10.1002/jor.23851
Influence of varying stem and metaphyseal sleeve size on the primary stability of cementless revision tibial trays used to reconstruct AORI IIA defects. A simulation study
Maged Awadalla (2018)
10.1016/J.CLINBIOMECH.2006.12.001
Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis.
I. A. J. Radcliffe (2007)
10.1016/j.jbiomech.2013.03.016
Effects of resection thickness on mechanics of resurfaced patellae.
Clare K Fitzpatrick (2013)
10.1108/mmms-06-2018-0109
Periprosthetic bone response to axial loading following TKR: Effect of polyethylene thickness and implant material – a finite element analysis study
Ravishanker B Baliga (2019)
10.1007/S12205-017-1437-5
The Effect of FEM Mesh Density on the Failure Probability Analysis of Structures
A. Ghavidel (2018)
10.1201/B17439-13
Femur Model for Predicting Strength and Fracture Risk
He Gong (2014)
10.1155/2017/5932545
Validation of Material Algorithms for Femur Remodelling Using Medical Image Data
Shitong Luo (2017)
10.1016/J.JBIOMECH.2007.03.013
Incorporating uncertainty in mechanical properties for finite element-based evaluation of bone mechanics.
P. Laz (2007)
10.1243/09544119JEIM119
Experimental validation of a finite element model of a composite tibia
H. Gray (2007)
10.1016/J.BBE.2014.05.001
Biomechanical analysis of diversified screw arrangement on 11 holes locking compression plate considering time-varying properties of callus
B. Sepehri (2014)
Graph Partitioning for the Finite Element Method: Reducing Communication Volume with the Directed Sorted Heavy Edge Matching
G. García (2019)
10.1002/jor.21211
Comparison of patellar bone strain in the natural and implanted knee during simulated deep flexion
Clare K Fitzpatrick (2011)
10.1007/s10439-012-0514-7
Relationships Between Femoral Strength Evaluated by Nonlinear Finite Element Analysis and BMD, Material Distribution and Geometric Morphology
H. Gong (2012)
10.1016/j.medengphy.2014.04.006
Prediction of structural failure of tibial bone models under physiological loads: effect of CT density-modulus relationships.
Mahmut Tuncer (2014)
10.4271/2013-01-1375
Effects of Mesh Density on Finite Element Analysis
Yucheng Liu (2013)
See more
Semantic Scholar Logo Some data provided by SemanticScholar