Converting Absorbed Dose To Medium To Absorbed Dose To Water For Monte Carlo Based Photon Beam Dose Calculations

Jeffrey V. Siebers, Paul J. Keall, Alan E. Nahum, Radhe Mohan
Published 2000 · Physics
Cite This
Download PDF
Analyze on Scholarcy
Share
Current clinical experience in radiation therapy is based upon dose computations that report the absorbed dose to water, even though the patient is not made of water but of many different types of tissue. While Monte Carlo dose calculation algorithms have the potential for higher dose accuracy, they usually transport particles in and compute the absorbed dose to the patient media such as soft tissue, lung or bone. Therefore, for dose calculation algorithm comparisons, or to report dose to water or tissue contained within a bone matrix for example, a method to convert dose to the medium to dose to water is required. This conversion has been developed here by applying Bragg-Gray cavity theory. The dose ratio for 6 and 18 MV photon beams was determined by computing the average stopping power ratio for the primary electron spectrum in the transport media. For soft tissue, the difference between dose to medium and dose to water is approximately 1.0%, while for cortical bone the dose difference exceeds 10%. The variation in the dose ratio as a function of depth and position in the field indicates that for photon beams a single correction factor can be used for each particular material throughout the field for a given photon beam energy. The only exception to this would be for the clinically non-relevant dose to air. Pre-computed energy spectra for 60 Co to 24 MV are used to compute the dose ratios for these photon beams and to determine an effective energy for evaluation of the dose ratio.



This paper is referenced by
Validación de un sistema de control de calidad pre-tratamiento 3D en técnicas volumétricas basado en matrices bidimensionales de detectores Commissioning of a 3D pretreatment quality-assurance system in volumetric techniques based in 2D detector arrays
Francisco Clemente Gutiérrez (2015)
10.1088/0031-9155/60/1/375
Phase space determination from measured dose data for intraoperative electron radiation therapy.
Eduardo Ríos Herranz (2015)
Research Monte Carlo dose verification of prostate patients treated with simultaneous integrated boost intensity modulated radiation therapy
Nesrin Dogan (2015)
10.1088/0031-9155/57/22/7615
Monte Carlo-based correction factors for ion chamber dosimetry in heterogeneous phantoms for megavoltage photon beams.
Fujio Araki (2012)
10.1118/1.4820443
Dosimetric evaluation of photon dose calculation under jaw and MLC shielding.
Antonella Fogliata (2013)
10.3109/0284186X.2013.822552
Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy
Hong-Wei Liu (2014)
10.14288/1.0067746
An electronic portal image-based monte carlo approach to in-vivo dosimetry for intensity modulated radiation therapy
Parmveer Atwal (2009)
10.1016/j.ejmp.2016.08.009
Potential pitfalls of the PTV concept in dose-to-medium planning optimization.
Edmond Sterpin (2016)
10.4236/ijmpcero.2018.71007
Comparison of Gamma Pass Rate between the Dose-to-Water and Dose-to-Medium Reporting Modes for Patient-Specific QA Using a Helical Diode Array Dosimeter with a Fixed Phantom Density
Hideaki Hirashima (2018)
10.14288/1.0074272
Incorporating microdosimetry into radiation therapy treatment planning with multi-scale Monte Carlo simulations
Joseph Lucido (2013)
10.1088/1361-6560/aa76b4
Multi-institutional MicroCT image comparison of image-guided small animal irradiators.
Christopher Daniel Johnstone (2017)
10.1155/2013/692874
A Review on the Use of Grid-Based Boltzmann Equation Solvers for Dose Calculation in External Photon Beam Treatment Planning
Monica W. K. Kan (2013)
10.1118/1.4792308
Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma.
Monica W. K. Kan (2013)
10.1120/jacmp.v17i5.6338
Difference in dose-volumetric data between the analytical anisotropic algorithm, the dose-to-medium, and the dose-to-water reporting modes of the Acuros XB for lung stereotactic body radiation therapy.
Wambaka Ange Mampuya (2016)
10.1016/j.ijrobp.2016.03.044
Dose Specification for NRG Radiation Therapy Trials.
David J. Gladstone (2016)
10.3938/JKPS.65.1829
Photon beam dosimetry with EBT3 film in heterogeneous regions: Application to the evaluation of dose-calculation algorithms
Hyunuk Jung (2014)
10.1088/0031-9155/55/17/001
RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation.
Sofie Ceberg (2010)
10.1088/0031-9155/54/13/022
A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans.
Olivier Pisaturo (2009)
The Difference Between a Collapsed Cone Based and a Monte Carlo Based Dose Calculation Algorithm
Victor Löf (2015)
Title Difference in dose-volumetric data between the analytical anisotropic algorithm , the dose-to-medium , and the dose-to-water reporting modes of the Acuros XB for lung stereotactic body radiation therapy
Wambaka Ange Mampuya (2019)
10.1088/0031-9155/51/22/005
Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations.
Tommy Knöös (2006)
10.3938/JKPS.66.1308
Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
Chung Il Lee (2015)
10.4236/IJMPCERO.2014.31010
Comparison of Absorbed Dose to Medium and Absorbed Dose to Water for Spine IMRT Plans Using a Commercial Monte Carlo Treatment Planning System
Muhammad Nauman Usmani (2014)
10.1109/TNS.2006.886039
Cobalt Therapy Dosimetric Calculations Over a Voxelized Heterogeneous Phantom: Validation of Different Monte Carlo Models and Methodologies Against Experimental Data
R. Miró (2006)
Implementation of Acuros XB in Treatment Planning of SBRT of Lung Cancer
Emma Hedin (2018)
10.1016/j.radonc.2012.11.012
Evaluation of organ-specific peripheral doses after 2-dimensional, 3-dimensional and hybrid intensity modulated radiation therapy for breast cancer based on Monte Carlo and convolution/superposition algorithms: implications for secondary cancer risk assessment.
Andreas Joosten (2013)
10.1118/1.3592646
Cerenkov emission induced by external beam radiation stimulates molecular fluorescence.
Johan Axelsson (2011)
Modelling Late Toxicity in Hypofractionated Radiation Therapy Development of Methods and Applications to Clinical Data
Niclas Pettersson (2013)
10.1118/1.4851555
Metallic artifact mitigation and organ-constrained tissue assignment for Monte Carlo calculations of permanent implant lung brachytherapy.
J. G. H. Sutherland (2014)
10.4236/JMP.2014.516162
Dosimetric Evaluation of Heterogeneities in Small Circular Fields of 6 MV Photon Beams with EBT2 and EDR2 Films: Comparison with Monte Carlo Calculation
Ali Jaffer Mohammad (2014)
10.1016/J.RADMEAS.2014.05.011
Measurement-based Monte Carlo simulation of high definition dose evaluation for nasopharyngeal cancer patients treated by using intensity modulated radiation therapy
Chi-Yuan Yeh (2014)
10.1088/0031-9155/60/6/2309
Reconstruction of organ dose for external radiotherapy patients in retrospective epidemiologic studies.
Choonik Lee (2015)
See more
Semantic Scholar Logo Some data provided by SemanticScholar