The Effect Of Very Small Air Gaps On Small Field Dosimetry.

Paul H. Charles, Scott B. Crowe, Tanya Kairn, Joseph Kenny, Juergen Lehmann, Jeanette Lye, Leon Dunn, Brendan Hill, Rhonda Talford Knight, C. M. Langton, Jamie Trapp
Published 2012 · Computer Science, Physics, Medicine
Cite This
Download PDF
Analyze on Scholarcy
Share
The purpose of this study was to investigate the effect of very small air gaps (less than 1 mm) on the dosimetry of small photon fields used for stereotactic treatments. Measurements were performed with optically stimulated luminescent dosimeters (OSLDs) for 6 MV photons on a Varian 21iX linear accelerator with a Brainlab µMLC attachment for square field sizes down to 6 mm × 6 mm. Monte Carlo simulations were performed using EGSnrc C++ user code cavity. It was found that the Monte Carlo model used in this study accurately simulated the OSLD measurements on the linear accelerator. For the 6 mm field size, the 0.5 mm air gap upstream to the active area of the OSLD caused a 5.3% dose reduction relative to a Monte Carlo simulation with no air gap. A hypothetical 0.2 mm air gap caused a dose reduction >2%, emphasizing the fact that even the tiniest air gaps can cause a large reduction in measured dose. The negligible effect on an 18 mm field size illustrated that the electronic disequilibrium caused by such small air gaps only affects the dosimetry of the very small fields. When performing small field dosimetry, care must be taken to avoid any air gaps, as can be often present when inserting detectors into solid phantoms. It is recommended that very small field dosimetry is performed in liquid water. When using small photon fields, sub-millimetre air gaps can also affect patient dosimetry if they cannot be spatially resolved on a CT scan. However the effect on the patient is debatable as the dose reduction caused by a 1 mm air gap, starting out at 19% in the first 0.1 mm behind the air gap, decreases to <5% after just 2 mm, and electronic equilibrium is fully re-established after just 5 mm.
This paper references
10.1016/S0958-3947(97)00001-0
Influence of air inhomogeneities in radiosurgical beams.
Anil K Rustgi (1997)
10.1088/0031-9155/53/20/R01
Optically stimulated luminescence (OSL) dosimetry in medicine.
Eduardo G. Yukihara (2008)
10.1118/1.3596533
Angular dependence of the nanoDot OSL dosimeter.
James R. Kerns (2011)
10.1088/0031-9155/55/17/N01
Adapting a generic BEAMnrc model of the BrainLAB m3 micro-multileaf collimator to simulate a local collimation device.
Tanya Kairn (2010)
ratio for absolute dosimetry
T DSolberg (1995)
10.1118/1.3355873
Technical Note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution: Modeling a complex mMLC with BEAMnrc
Tanya Kairn (2010)
10.3109/0284186X.2010.551665
A contemporary review of stereotactic radiotherapy: Inherent dosimetric complexities and the potential for detriment
Michael L. Taylor (2011)
BEAMDP Users Manual (Ottawa: National Research Council) Mrcela I, Bokulic T
Med. Phys (2009)
10.1088/0031-9155/57/6/1543
An in-depth Monte Carlo study of lateral electron disequilibrium for small fields in ultra-low density lung: implications for modern radiation therapy.
Brandon Disher (2012)
10.1118/1.3658572
Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors.
Gavin Cranmer-Sargison (2011)
10.1007/s13246-011-0102-4
Determination of RW3-to-water mass-energy absorption coefficient ratio for absolute dosimetry
Katrina Y. T. Seet (2011)
10.1118/1.2815356
Small fields: nonequilibrium radiation dosimetry.
Indra J. Das (2008)
Optically Stimulated Luminescence
astronomy Physics (2011)
10.1088/0031-9155/56/18/018
Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.
Iva Mrčela (2011)
10.1118/1.2804555
Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements.
Paul A. Jursinic (2007)
10.1118/1.3005481
A new formalism for reference dosimetry of small and nonstandard fields.
Rodolfo Alfonso (2008)
10.1118/1.1386780
Evaluating the effectiveness of a longitudinal magnetic field in reducing underdosing of the regions around upper respiratory cavities irradiated with photon beams--a Monte Carlo study.
Shada Wadi-Ramahi (2001)
10.1088/0031-9155/51/22/015
Dose build-up behind air cavities for Co-60, 4, 6 and 8 MV. Measurements and Monte Carlo simulations.
Claus F. Behrens (2006)
10.1118/1.3355873
Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution.
Tanya Kairn (2010)
10.1118/1.598966
A systematic evaluation of air cavity dose perturbation in megavoltage x-ray beams.
X Allen Li (2000)
10.1016/0360-3016(94)00495-7
Implications of tissue heterogeneity for radiosurgery in head and neck tumors.
Timothy D. Solberg (1995)
10.1118/1.3660770
Calculation of k(Q(clin),Q(msr) ) (f(clin),f(msr) ) for several small detectors and for two linear accelerators using Monte Carlo simulations.
Paolo Francescon (2011)
Determination of RW 3towater mass - energy absorption coefficient ratio for absolute dosimetry Australas
D SolbergT (2011)



This paper is referenced by
10.1088/1742-6596/489/1/012006
The influence of Monte Carlo source parameters on detector design and dose perturbation in small field dosimetry
Paul H. Charles (2014)
10.1088/1742-6596/489/1/012014
Using narrow beam profiles to quantify focal spot size, for accurate Monte Carlo simulations of SRS/SRT systems
Tanya Kairn (2013)
2D Monolithic silicon detectors for dosimetry in Small beam radiotherapy (Stereotactic Radiotherapy)
Al Shukaili (2018)
Development of a multi-detector quality assurance instrument for intensity modulated radiotherapy
C S Porumb (2016)
10.1088/1748-0221/14/06/P06018
The effect of an air gap on a 2D monolithic silicon detector for relative dosimetry
Kananan Utitsarn (2019)
10.1002/acm2.12744
Two‐dimensional solid‐state array detectors: A technique for in vivo dose verification in a variable effective area
Kananan Utitsarn (2019)
10.1088/1742-6596/777/1/012020
The angular dependence of a two dimensional monolithic detector array for dosimetry in small radiation fields
Nauljun Stansook (2017)
10.1007/s13246-015-0334-9
Clinical use of diodes and micro-chambers to obtain accurate small field output factor measurements
Tanya Kairn (2015)
Very small field dosimetry
Paul Charles (2014)
10.1007/978-981-10-9023-3_103
Long-Term Reliability of Optically Stimulated Luminescence Dosimeters
Tanya Kairn (2019)
10.1016/J.RADMEAS.2013.12.004
Response variation of optically stimulated luminescence dosimeters
Andre Asena (2014)
10.1118/1.4896097
A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom.
Jessica E Lye (2014)
10.1118/1.4894728
Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry.
Paul H. Charles (2014)
Monte Carlo simulation and dosimetric studies for small fields in lung stereotactic body radiation therapy
Roger Cai Xiang Soh (2018)
10.1007/s13246-017-0570-2
Feasibility of 3D printed air slab diode caps for small field dosimetry
Benjamin Perrett (2017)
10.1088/0031-9155/60/20/8187
Breakdown of Bragg-Gray behaviour for low-density detectors under electronic disequilibrium conditions in small megavoltage photon fields.
Sudhir Kumar (2015)
10.1007/s13246-015-0365-2
Characterising an aluminium oxide dosimetry system
Clement F. Conheady (2015)
10.1007/s13246-020-00861-8
Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods
Simon Maxwell (2020)
10.1002/acm2.12364
Real‐time high spatial resolution dose verification in stereotactic motion adaptive arc radiotherapy
Mitchell Duncan (2018)
10.1088/0031-9155/58/13/4501
Monte Carlo-based diode design for correction-less small field dosimetry.
Paul H. Charles (2013)
10.1120/jacmp.v17i1.5773
Percentage depth dose calculation accuracy of model based algorithms in high energy photon small fields through heterogeneous media and comparison with plastic scintillator dosimetry
Ananda Giri Babu Alagar (2016)
10.1002/acm2.12345
“Characterization of ELEKTA SRS cone collimator using high spatial resolution monolithic silicon detector array”
Khalsa Al Shukaili (2018)
10.1118/1.4926778
Angular independent silicon detector for dosimetry in external beam radiotherapy.
Marco Petasecca (2015)
10.1002/mp.12060
A 2D silicon detector array for quality assurance in small field dosimetry: DUO
Khalsa Al Shukaili (2017)
10.1007/s13246-020-00859-2
A novel extrapolation method using OSL detectors for very small field output factor measurement for stereotactic radiosurgery
Te-An Polly Huang (2020)
10.1002/mp.13839
AAPM TG 191 Clinical Use of Luminescent Dosimeters: TLDs and OSLDs.
Stephen F. Kry (2019)
10.1016/j.rpor.2019.12.011
In vivo monitoring of total skin electron dose using optically stimulated luminescence dosimeters.
Tanya Kairn (2020)
10.1118/1.4892384
A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512.
Abdullah H. Aldosari (2014)
10.1118/1.4928602
Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system.
Sean Tanny (2015)
10.1118/1.4868461
A practical and theoretical definition of very small field size for radiotherapy output factor measurements.
Paul H. Charles (2014)
10.4225/23/5a52bdc65589d
Dosimetric comparison of dynamic conformal arc therapy to volumetric modulated arc therapy and 30 conformal radiotherapy in stereotactic ablative radiotherapy treatments for lung cancer
Jonathon Thompson (2017)
10.1016/j.radonc.2013.10.002
A methodological approach to reporting corrected small field relative outputs.
Gavin Cranmer-Sargison (2013)
See more
Semantic Scholar Logo Some data provided by SemanticScholar