Online citations, reference lists, and bibliographies.

Multidetector Computed Tomography Imaging: Effect Of Sparse Sampling And Iterative Reconstruction On Trabecular Bone Microstructure

M. Mookiah, K. Subburaj, K. Mei, F. Kopp, J. Kaesmacher, P. Jungmann, P. Foehr, P. Noel, J. Kirschke, T. Baum
Published 2018 · Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
Abstract Multidetector computed tomography–based trabecular bone microstructure analysis ensures promising results in fracture risk prediction caused by osteoporosis. Because multidetector computed tomography is associated with high radiation exposure, its clinical routine use is limited. Hence, in this study, we investigated in 11 thoracic midvertebral specimens whether trabecular texture parameters are comparable derived from (1) images reconstructed using statistical iterative reconstruction (SIR) and filtered back projection as criterion standard at different exposures (80, 150, 220, and 500 mAs) and (2) from SIR-based sparse sampling projections (12.5%, 25%, 50%, and 100%) and equivalent exposures as criterion standard. Twenty-four texture features were computed, and those that showed similar values between (1) filtered back projection and SIR at the different exposure levels and (2) sparse sampling and equivalent exposures and reconstructed with SIR were identified. These parameters can be of equal value in determining trabecular bone microstructure with lower radiation exposure using sparse sampling and SIR.
This paper references
10.2214/AJR.10.4573
Impact of Adaptive Statistical Iterative Reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis.
Daniel M Cornfeld (2011)
10.1088/0031-9155/53/17/021
Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.
E. Sidky (2008)
10.1007/s11154-006-9004-2
New imaging technologies in the diagnosis of osteoporosis
G. Kazakia (2006)
10.1007/BF01025868
On the histogram as a density estimator:L2 theory
D. Freedman (1981)
10.1109/TSMC.1973.4309314
Textural Features for Image Classification
R. Haralick (1973)
10.1016/0167-8655(91)80014-2
Image characterizations based on joint gray level-run length distributions
B. V. Dasarathy (1991)
10.4103/0256-4602.101306
Computer-aided Detection and Analysis of Pulmonary Nodule from CT Images: A Survey
Ashis Kumar Dhara (2012)
10.1148/radiol.09090094
Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm--initial clinical experience.
D. Marin (2010)
10.1148/rg.315105712
Integrated imaging approach to osteoporosis: state-of-the-art review and update.
G. Guglielmi (2011)
10.1016/0167-8655(90)90112-F
Use of gray value distribution of run lengths for texture analysis
A. Chu (1990)
10.2214/AJR.09.2397
Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study.
A. Hara (2009)
10.1093/mnras/276.1.336
Variance, Skewness and Kurtosis: results from the APM Cluster Redshift Survey and Model Predictions
E. Gaztañaga (1995)
10.2214/AJR.11.6907
Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT.
Peter B. Noël (2011)
Link and Ursula Heilmeier . Bone quality — beyond bone mineral density
AK Dhara (2016)
10.1109/4233.992163
Fractal analysis in the detection of colonic cancer images
A. N. Esgiar (2002)
10.1109/42.952732
Analysis of asymmetry in mammograms via directional filtering with Gabor wavelets
R. Ferrari (2001)
10.1186/2193-1801-2-209
Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
K. Yasaka (2013)
10.2967/jnumed.110.082404
Intratumor Heterogeneity Characterized by Textural Features on Baseline 18F-FDG PET Images Predicts Response to Concomitant Radiochemotherapy in Esophageal Cancer
F. Tixier (2011)
10.1007/s00198-005-1994-1
Three-dimensional texture analysis of cancellous bone cores evaluated at clinical CT resolutions
Chad Showalter (2005)
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
E. Sidky (2006)
10.4172/2167-7964.1000147
Image Quality and Radiation Dose Comparison between Filtered Back Projection and Adaptive Statistical Iterative Reconstruction in Non-contrast Head CT Studies
Seth L. Alper (2013)
[CT-expo--a novel program for dose evaluation in CT].
G. Stamm (2002)
10.1038/ncomms5006
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
H. Aerts (2014)
10.1109/TMI.2014.2350962
Combining Ordered Subsets and Momentum for Accelerated X-Ray CT Image Reconstruction
D. Kim (2015)
10.2214/AJR.09.2989
Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients.
Y. Sagara (2010)
10.1109/34.56205
Scale-Space and Edge Detection Using Anisotropic Diffusion
P. Perona (1990)
10.1196/ANNALS.1346.038
Advanced imaging assessment of bone quality.
H. Genant (2006)
A radiomics model from joint FDG-PET and MRI texture features for the prediction of lung metastases in soft-tissue sarcomas of the extremities
Z. Zhou (2015)
10.1140/EPJNBP/S40366-015-0018-0
Application of texture analysis to muscle MRI: 2 – technical recommendations
Richard A Lerski (2015)
10.1088/0266-5611/25/12/123009
Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?
X. Pan (2009)
10.1371/journal.pone.0081141
Does Iterative Reconstruction Lower CT Radiation Dose: Evaluation of 15,000 Examinations
P. Noël (2013)
10.1007/s00330-011-2186-3
Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose
L. Mitsumori (2011)
10.1016/j.patcog.2008.08.011
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
I. El-Naqa (2009)
10.1016/S0146-664X(75)80008-6
Texture analysis using gray level run lengths
M. Galloway (1975)
10.1186/s12880-015-0066-z
Osteoporosis imaging: effects of bone preservation on MDCT-based trabecular bone microstructure parameters and finite element models
T. Baum (2015)
10.1007/s00774-017-0836-5
Effect of radiation dose reduction on texture measures of trabecular bone microstructure: an in vitro study
Muthu Rama Krishnan Mookiah (2017)
10.1117/12.2216175
Effect of low-dose CT and iterative reconstruction on trabecular bone microstructure assessment
Felix K. Kopp (2016)
fragility in glucocorticoid - induced osteoporosis
H Jeong (2011)
10.1259/bjr.20101115
Computerised analysis of osteoporotic bone patterns using texture parameters characterising bone architecture.
H. Jeong (2013)
10.1038/srep38441
Effects of dose reduction on bone strength prediction using finite element analysis
D. Anitha (2016)
10.1007/s00330-012-2424-3
Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults
Gaurav S. Desai (2012)
10.1118/1.4825096
Effects of sparse sampling schemes on image quality in low-dose CT.
Sajid Abbas (2013)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar