The natural tapering of coronary arteries often creates a dilemma for optimal balloon sizing during stenting. The influence of different balloon types, namely, a tapered balloon and a conventional cylindrical balloon, on the mechanical performance of the stent as well as arterial mechanics was investigated via the finite element method. Stent free-expansion and stent deployment in a stenotic tapered artery were investigated numerically. The biomechanical behavior of the two balloon types was compared in terms of stent foreshortening, stent deformation, stent stress distribution, and arterial wall stress distribution. Results indicate that balloon types affect the transient behavior of the stent and the arterial mechanics. Specifically, a tapered balloon could maintain the natural tapering of the coronary artery after stent expansion. In contrast to a cylindrical balloon, tapered balloon also mitigated the foreshortening of the stent (7.69%) as well as the stress concentration in the stent and artery (8.61% and 4.17%, respectively). Hence, tapered balloons should be used in tapered arteries as they may result in low risk of artery injury. This study might provide insights for improved balloon choice and pre-surgical planning.
This paper references
10.1002/ccd.22132
Acute fracture of ACCULINK carotid stent during post dilation.
Najibullah Habib (2009)
10.1002/ccd.27539
First report of the use of long‐tapered sirolimus‐eluting coronary stent for the treatment of chronic total occlusions with the hybrid algorithm
Carlo Zivelonghi (2018)
10.1177/0300060517708515
Over-expansion of drug-eluting stents in patients with left main coronary artery disease: An in vivo study
Yicong Ye (2017)
10.1016/S0002-9149(00)80072-7
Intravascular ultrasound assessment of the magnitude and mechanism of coronary artery and lumen tapering.
S P Javier (1995)
10.1007/s10439-014-1237-8
Computational Modelling of Multi-folded Balloon Delivery Systems for Coronary Artery Stenting: Insights into Patient-Specific Stent Malapposition
Georgios E. Ragkousis (2014)
10.1038/labinvest.2011.57
INCREASED ARTERY WALL STRESS POST-STENTING LEADS TO GREATER INTIMAL THICKENING
Lucas H. Timmins (2011)
10.1016/j.medengphy.2013.01.007
Patient-specific simulations of stenting procedures in coronary bifurcations: two clinical cases.
Stefano Morlacchi (2013)
10.1080/10255842.2013.873420
Numerical investigations of the mechanical properties of a braided non-vascular stent design using finite element method
Xiaoyu Ni (2015)
10.1017/JMECH.2018.23
Bending Analysis of Stented Coronary Artery: the Interaction Between Stent and Vessel
Xiang Shen (2019)
10.1152/japplphysiol.00245.2017
Biomechanical impact of provisional stenting and balloon dilatation on coronary bifurcation: clinical implications.
Henry Y. Chen (2017)
10.1111/aor.12638
Hemodynamic Performance of a New Punched Stent Strut: A Numerical Study.
Yan Xue (2016)
10.1007/s10439-008-9582-0
Mechanical Modeling of Stents Deployed in Tapered Arteries
Lucas H. Timmins (2008)
10.1016/0002-9149(92)91303-L
Effectiveness of decremental diameter balloon catheters (tapered balloon).
Vidya S. Banka (1992)
10.1016/j.ijcard.2016.11.005
Assessment of the hemodynamic characteristics of Absorb BVS in a porcine coronary artery model.
Erhan Tenekecioglu (2017)
10.2174/1381612825666181204115124
Patient-specific Finite Element Model of Coronary Artery Stenting.
Reza Razaghi (2018)
10.1179/1743132813Y.0000000180
Simulated biomechanical responses at a curved arterial segment after Wingspan Stent deployment in swine
Motoaki Fujimoto (2013)
10.1111/aor.12001
A comparative reliability and performance study of different stent designs in terms of mechanical properties: foreshortening, recoil, radial force, and flexibility.
Dong Bin Kim (2013)
10.1002/ccd.21027
Stent fracture: an unusual cause of late restenosis after sirolimus-eluting stent placement.
Anderson P Mehrle (2007)
Normal angiographic tapering of the coronary arteries.
Mohammad Zubaid (2002)
10.1016/j.jocn.2018.10.118
Efficacy and safety of drug-eluting stent for the intracranial atherosclerotic disease: A systematic review and meta-analysis
Gengfan Ye (2019)
10.1016/J.JBIOMECH.2007.08.014
Realistic finite element-based stent design: the impact of balloon folding.
Matthieu De Beule (2008)
10.1142/S1758825111001044
Effects of Geometric Variations on the Buckling of Arteries.
Parag Datir (2011)
10.1179/1743132812Y.0000000119
Biomechanical responses after Wingspan Stent deployment in swine ascending pharyngeal artery
Motoaki Fujimoto (2013)
10.1016/j.msec.2014.05.057
Effects of material, coating, design and plaque composition on stent deployment inside a stenotic artery--finite element simulation.
Alessandro Schiavone (2014)
10.1142/S1758825110000718
EFFECTS OF BALLOON LENGTH AND COMPLIANCE ON VASCULAR STENT EXPANSION
Fangsen Cui (2010)
10.1016/S0002-9149(97)89307-1
Angiographic and procedural outcome after coronary angioplasty in high-risk subsets using a decremental diameter (tapered) balloon catheter. Tapered Balloon Registry Investigators.
John R. Laird (1996)
10.1016/j.jmbbm.2007.07.002
On the finite element modelling of balloon-expandable stents.
Feng Ju (2008)
10.1142/S0219519416400157
ASSESSMENT OF CORONARY STENT DEPLOYMENT IN TAPERED ARTERIES: IMPACT OF ARTERIAL TAPERING
Xiang Shen (2016)
10.1002/cnm.2557
Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
David Moral Martín (2013)
10.21037/JTD.2016.10.93
Understanding and managing in-stent restenosis: a review of clinical data, from pathogenesis to treatment.
Dario Buccheri (2016)
10.1016/j.jacc.2014.01.019
Mechanisms, pathophysiology, and clinical aspects of incomplete stent apposition.
Guilherme Ferragut Attizzani (2014)



Semantic Scholar Logo Some data provided by SemanticScholar