Analysis Of Side Branch Access During Bifurcation Stenting

Peter Mortier, Matthieu De Beule, Denis Van Loo, Benedict Verhegghe, P. Verdonck
Published 2008 · Medicine
Cite This
Download PDF
Analyze on Scholarcy
Share
A common technique to improve the local blood flow through stenotic arteries involves the implantation of a metallic scaffold known as a stent. These devices have shown excellent results in unbranched vessels. However, the treatment of coronary bifurcation lesions remains an enormous challenge and is generally associated with an increased complication rate. Many different techniques have been proposed in clinical literature, but all the suggested methodologies have specific limitations [1]. In many cases, a stent is deployed in the main branch (MB) and logically, this compromises the side branch (SB) patency. This is a frequently encountered situation that can be improved by balloon dilatation through the side of the MB stent (fig. 1). However, such balloon inflation may result in unwanted distortions of the stent [2].Copyright © 2008 by ASME



This paper is referenced by
Flow characteristics and wall shear stresses in bifurcated peripheral arteries
Aneesha Gogineni (2015)
CORONARY INTERVENT IONS
Jens Flensted Lassen (2014)
10.4244/
Consensus from the 5th European Bifurcation Club meeting.
David J R Hildick-Smith (2010)
Modelling of Stent Deployment and Deformation in Diseased Arteries by Considering Vessel Anisotropy Modelling of Stent Deployment and Deformation in Diseased Arteries by Considering Vessel Anisotropy
Attilio Schiavone (2015)
10.1002/cnm.2557
Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
David Moral Martín (2013)
10.4244/EIJV10I5A97
Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings.
Jens Flensted Lassen (2014)
10.21427/D7G31Z
Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents.
David D Martin (2013)
Computer simulations in stroke prevention : design tools and strategies towards virtual procedure planning
Francesco Iannaccone (2014)
10.1016/j.jcin.2015.06.015
Biomechanical Modeling to Improve Coronary Artery Bifurcation Stenting: Expert Review Document on Techniques and Clinical Implementation.
Antonios P. Antoniadis (2015)
10.1115/SBC2011-53224
EFFECTS OF KNEE FLEXION ON STENTED PERIPHERAL ARTERIES - A COMPUTATIONAL AND IN VITRO STUDY
Ríona Ní Ghriallais (2011)
10.1007/s11517-011-0815-2
The consequences of the mechanical environment of peripheral arteries for nitinol stenting
Michael Early (2011)
10.1186/S40759-014-0002-X
A study of balloon type, system constraint and artery constitutive model used in finite element simulation of stent deployment
Alessandro Schiavone (2015)
Analysis and Implementation of Mixed-Mode Cohesive Zone Formulations for Cardiovascular Biomechanics Applications
Éamonn Ó Máirtín (2013)
10.1007/s10237-010-0196-8
Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning
Dario Gastaldi (2010)
Image-Based Quantification Workflow for Coronary Morphology: A Tool for Use in Next-Generation Bifurcation Stent Design
Sara Marie Nomeland (2010)
10.1002/ccd.22596
Coronary artery bifurcation biomechanics and implications for interventional strategies.
James E. Moore (2010)
The Development of a Computational Test-Bed to Assess Coronary Stent Implantation
Claire Conway (2013)
10.1007/s10439-009-9836-5
A Novel Simulation Strategy for Stent Insertion and Deployment in Curved Coronary Bifurcations: Comparison of Three Drug-Eluting Stents
Peter Mortier (2009)
Semantic Scholar Logo Some data provided by SemanticScholar