Online citations, reference lists, and bibliographies.

Metal-on-metal Joint Bearings And Hematopoetic Malignancy

P. H. Wagner, Håkan Olsson, Jonas Ranstam, Otto Robertsson, Ming Hao Zheng, Lars Åke Alvar Lidgren
Published 2012 · Medicine
Cite This
Download PDF
Analyze on Scholarcy
Share
Abstract This is a review of the hip arthroplasty era. We concentrate on new metal bearings, surface replacements, and the lessons not learned, and we highlight recent reports on malignancies and joint implants. A low incidence of blood malignancies has been found in bone marrow taken at prosthetic surgery. The incidence is increased after replacement with knee implants that release very low systemic levels of metal ions. A carcinogenic effect of the high levels of metal ions released by large metal-on-metal implants cannot be excluded. Ongoing Swedish implant registry studies going back to 1975 can serve as a basis for evaluation of this risk.
This paper references
10.1016/j.arth.2009.04.007
Long-term survival and reason for revision of Wagner resurfacing hip arthroplasty.
Kerry Costi (2010)
10.1002/art.30134
The risk of cancer in patients with rheumatoid arthritis: a nationwide cohort study in Taiwan.
Yi-Ju Chen (2011)
10.1136/bmj.4.5993.374
Metal sensitivity in patients with joint replacement arthroplasties.
Michael K. D. Benson (1975)
10.1620/tjem.185.253
Concentration of metal elements in the blood and urine in the patients with cementless total knee arthroplasty.
T. K. Liu (1998)
10.1302/0301-620X.90B10.20533
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement.
Roel de Haan (2008)
10.3109/17453674.2011.579518
Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty
Henry Wynn-Jones (2011)
10.1136/ard.2008.096925
Rheumatoid arthritis, treatment with corticosteroids and risk of malignant lymphomas: results from a case–control study
Karin Hellgren (2010)
10.3109/17453679209154776
Polyethylene wear in unicondylar knee prostheses. 106 retrieved Marmor, PCA, and St Georg tibial components compared.
Gordon Blunn (1992)
10.1097/00003086-199608001-00007
Experience With the Metasul Total Hip Bearing System
Ben George Weber (1996)
10.1302/0301-620X.90B9.20785
The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip.
David John Langton (2008)
10.1136/bmj.e1349
Ongoing problems with metal-on-metal hip implants
Carl J Heneghan (2012)
10.2106/JBJS.J.00133
Histopathology of femoral head donations: a retrospective review of 6161 cases.
Katherine E. Mackie (2011)
10.1002/art.30653
Observational studies on the risk of cancer associated with tumor necrosis factor inhibitors in rheumatoid arthritis: a review of their methodologies and results.
Daniel H. Solomon (2012)
10.3109/17453678008990855
Hip replacement with the McKee-Farrar prosthesis in rheumatoid arthritis.
Halldór Baldursson (1980)
10.1016/S0883-5403(97)90024-3
Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses.
Gordon Blunn (1997)
Differences in metal ion release following cobalt-chromium and oxidized zirconium total knee arthroplasty.
Simon Garrett (2010)
10.1258/acb.2011.011141
Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants
Barry A. Sampson (2012)
10.1002/art.24941
Cancer risk in patients with rheumatoid arthritis treated with anti-tumor necrosis factor alpha therapies: does the risk change with the time since start of treatment?
Johan Askling (2009)
10.1016/S0140-6736(12)60353-5
Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales
Alison Steinberg Jean Smith (2012)
10.1302/0301-620X.30B1.59
Evolution of mould arthroplasty of the hip joint.
M. N. Smith-Petersen (1948)
10.1302/0301-620X.92B10.23504
Birmingham hip resurfacing: the prevalence of failure.
Andrew D. Carrothers (2010)
10.1111/j.1445-5994.1996.tb02940.x
Rheumatic manifestations of the myelodysplastic syndromes: a comparative study.
George Chellin Chandran (1996)
10.1097/00003086-197807000-00014
Surface replacement arthroplasty of the hip.
H-J. Wagner (1978)
Mini - mum 5 - Year Results of Modular Metal - On - Metal Total Hip Arthroplasty
K Kindsfater (2012)
10.1097/BCO.0b013e318219887a
Metal-on-metal articulation in total hip arthroplasty: update
Anand Srinivasan (2011)
10.1097/00003086-200209000-00013
Long-Term Survival of McKee-Farrar Total Hip Prostheses
Stephen R. Brown (2002)
10.1038/sj.jid.5700373
Caged-iron chelators a novel approach towards protecting skin cells against UVA-induced necrotic cell death.
Anthie Yiakouvaki (2006)
10.1302/0301-620X.81B2.9320
The pathology of bone allograft.
Simon H Palmer (1999)
10.1136/bmj.e2383
Risk of cancer in first seven years after metal-on-metal hip replacement compared with other bearings and general population: linkage study between the National Joint Registry of England and Wales and hospital episode statistics
Alison Steinberg Jean Smith (2012)
10.3109/17453674.2010.537805
Prevention of deep infection in joint replacement surgery
Esa R Jämsen (2010)
10.1007/978-3-642-10858-7_5
Thinking about the role (largely ignored) of heavy metals in cancer prevention: hexavalent chromium and melanoma as a case in point.
Frank L. Meyskens (2011)
10.2106/JBJS.J.01612
Pseudotumors associated with total hip arthroplasty.
Joseph Daniel (2012)
10.1136/bmj.d2905
Out of joint: The story of the ASR
Deborah R. Cohen (2011)
10.2106/00004623-196648020-00003
Epiphyseal transplantation. A clinical study.
James N. Wilson (1966)
10.2106/JBJS.J.01727
Five-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry.
Richard de Steiger (2011)
10.1088/0952-4746/29/2A/S04
Cancer and non-cancer effects in Japanese atomic bomb survivors.
Mark P. Little (2009)
10.1016/S0140-6736(07)60457-7
The operation of the century: total hip replacement
Ian Douglas Learmonth (2007)
10.1016/j.arth.2011.04.015
Cementless Metasul metal-on-metal total hip arthroplasties at 13 years.
Filippo Randelli (2012)
10.1016/j.ejca.2010.11.023
Increased cancer risks among arthroplasty patients: 30 year follow-up of the Swedish Knee Arthroplasty Register.
P. H. Wagner (2011)
10.2106/00004623-200004000-00004
Charnley Total Hip Arthroplasty with Cement: Minimum Twenty-five-Year Follow-up*
John J. Callaghan (2000)
Charn - ley total hip arthroplasty with cement . Minimum twenty - five - year follow - up
J Callaghan (2000)
10.2106/JBJS.J.01884
Prevalence of pseudotumor in asymptomatic patients after metal-on-metal hip arthroplasty.
Daniel H. Williams (2011)
Avascular necrosis of the femoral head in chronic myeloid leukemia patients treated with interferon-alpha: a synergistic correlation?
Peter S. Kozuch (2000)
10.1016/S0140-6736(61)92063-3
Arthroplasty of the hip. A new operation.
J. R. Charnley (1961)
Five-Year Results of the ASR XL Acetabular System and the ASR Hip Resurfacing System
Richard De Steiger (2011)
10.1002/(SICI)1097-0215(19960927)68:1<30::AID-IJC6>3.0.CO;2-Y
Overall cancer incidence not increased after prosthetic knee replacement: 14,551 patients followed for 66,622 person-years.
Stefan Lewold (1996)
10.1302/0301-620X.91B6.21682
The painful metal-on-metal hip resurfacing.
Alister J. Hart (2009)
10.3109/17453679209154804
Polyethylene wear in knee arthroplasty
Stuart B Goodman (1992)
10.1093/jnci/87.1.28
Cancer risk after hip replacement with metal implants: a population-based cohort study in Sweden.
Olof Nyrén (1995)
10.1002/1097-0142(20001001)89:7<1482::AID-CNCR10>3.0.CO;2-T
Avascular necrosis of the femoral head in chronic myeloid leukemia patients treated with interferon-α : A synergistic correlation?
Peter S. Kozuch (2000)
10.1002/jmri.23523
Magnetic resonance imaging of the postoperative hip.
Catherine L. Hayter (2012)
10.1007/s11999-010-1262-3
Risk of Complication and Revision Total Hip Arthroplasty Among Medicare Patients with Different Bearing Surfaces
Kevin John Bozic (2010)
10.1002/jor.1100070302
Cobalt, chromium, and nickel concentrations in body fluids of patients with porous-coated knee or hip prostheses.
Frederick William Sunderman (1989)
10.1158/1055-9965.EPI-06-0127
Cancer after Total Joint Arthroplasty: A Meta-analysis
Tracy Onega (2006)
10.1016/j.arth.2008.04.008
Femoral neck fractures after hip resurfacing.
Robert-Tobias Steffen (2009)
10.1302/0301-620X.86B2.14600
Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis.
Joseph Daniel (2004)
10.1302/0301-620X.90B1.19823
Chronic inflammation, joint replacement and malignant lymphoma.
Lars Åke Alvar Lidgren (2008)
10.1136/bmj.1.5852.527
Concentration of Wear Products in Hair, Blood, and Urine after Total Hip Replacement
Robert F. Coleman (1973)
10.1302/0301-620X.48B2.245
Replacement of arthritic hips by the McKee-Farrar prosthesis.
G. K. Mckee (1966)
10.1016/j.arth.2011.07.002
Minimum 5-year results of modular metal-on-metal total hip arthroplasty.
Kirk A Kindsfater (2012)
10.1186/1471-2474-10-53
B-cell Lymphoma in retrieved femoral heads: a long term follow up
Eline W. Zwitser (2009)
10.1080/000164701317268969
Joint prosthetic infections: A success story
Lars Åke Alvar Lidgren (2001)
10.1016/s0276-1092(08)79291-5
Serum Metal Ion Exposure after Total Knee Arthroplasty
Bernard F. Morrey (2008)
10.1302/0301-620X.56B4.626
Metal sensitivity as a cause of bone necrosis and loosening of the prosthesis in total joint replacement.
Eileen M. Evans (1974)
10.1007/s007760050038
Evolution and future of surface replacement of the hip
Harlan C. Amstutz (1998)
10.1243/095441105X63282
Cancer incidence and causes of death among total hip replacement patients: A review based on Nordic cohorts with a special emphasis on metal-on-metal bearings
Tuomo I Visuri (2006)
10.3109/17453678208992851
Surface replacement of the hip in chronic arthritis. A clinical, radiographic and roentgen stereophotogrammetric evaluation.
Brynjólfur Mogensen (1982)
Polyethylene wear in knee arthroplasty. A review.
Stuart B Goodman (1992)
10.1021/ac801817k
Intracellular chemical imaging of the developmental phases of human neuromelanin using synchrotron X-ray microspectroscopy.
Sylvain Bohic (2008)



This paper is referenced by
10.1007/s00132-019-03839-x
Nachweis hoch seltener periprothetischer maligner Neoplasien
Kevin Keidel (2019)
10.26717/bjstr.2018.05.001279
How is the Toxicity of Heavy Metals Detected in the Problems of Metal-Metal Hip Arthroplasties?
A. Fernandez-Ibanez (2018)
On the Epidemiology of Soft Tissue Sarcoma and Risk of Cancer following Knee prosthesis surgery. Important factors and methodological notes
P. H. Wagner (2017)
10.1016/j.actbio.2014.06.004
Bone and metal: an orthopaedic perspective on osseointegration of metals.
Vitali Goriainov (2014)
10.13172/2050-2303-2-4-950
The Evolution of Total Hip Arthroplasty (THA)
Ih Abdulkareem (2013)
10.1016/j.recot.2014.01.008
[Detection of metal ions in hair after metal-metal hip arthroplasty].
Daniel Hernandez-Vaquero (2014)
10.1007/s40735-018-0188-2
SMART Biosensor for Early Diagnostic Detection of Metal Ion Release in Orthopedic Patients: Initial Outcome
Mathew T. Mathew (2018)
10.3109/0284186X.2015.1119884
Young patients with hematologic and lymphatic malignancies have an increased risk of hip and knee arthroplasty
Tuukka T. Niinimäki (2016)
10.1136/bcr-2013-010422
Pain and fracture after anterior cruciate ligament reconstruction caused by giant cell tumour of the distal femur
Daniel Dowen (2013)
10.1371/journal.pone.0204356
The risk of developing cancer following metal-on-metal hip replacement compared with non metal-on-metal hip bearings: Findings from a prospective national registry “The National Joint Registry of England, Wales, Northern Ireland and the Isle of Man”
Linda P. Hunt (2018)
10.1016/J.RECOT.2014.01.008
Detección de iones metálicos en cabello tras artroplastia de cadera metal-metal
Daniel Hernandez-Vaquero (2014)
Risk of dislocation, cancer and mortality following hip arthroplasty
Elina Ekman (2019)
10.1080/17453674.2018.1431854
Risk of cancer after primary total hip replacement: The influence of bearings, cementation and the material of the stem
Vesna Levašič (2018)
10.1080/08989621.2017.1405259
Grave fraudulence in medical device research: a narrative review of the PIN seeding study for the Pinnacle hip system
Joan E. Steffen (2018)
Metal-on-metal hip resurfacing – medium-term results, prevalence and risk factors for adverse reaction to metal debris
Aleksi Reito (2014)
10.1177/0954411914541830
Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement
Xijin Hua (2014)
10.1016/J.RECOT.2015.07.002
Encuesta sobre el uso y comportamiento de las prótesis de cadera metal-metal en España
N. Calcerrada (2016)
10.2131/FTS.3.1
Physiological conditions in iPRECIO® -implanted rats
Masaru Tsuboi (2016)
10.1007/s10856-013-5116-x
Release of Cu2+ from a copper-filled TiO2 coating in a rabbit model for total knee arthroplasty
Andreas Mauerer (2013)
10.1016/J.RECOTE.2014.06.003
Detection of metal ions in hair after metal–metal hip arthroplasty
Daniel Hernandez-Vaquero (2014)
10.1016/J.RECOTE.2015.11.004
Survey on the use and behaviour of metal-on-metal hip replacements in Spain
N. Calcerrada (2016)
10.1007/s00256-017-2612-y
Development of malignant lymphoma after metal-on-metal hip replacement: a case report and review of the literature
Claire Louise McCarthy (2017)
10.1115/1.4040249
Finite Element Analysis to Probe the Influence of Acetabular Shell Design, Liner Material, and Subject Parameters on Biomechanical Response in Periprosthetic Bone.
Subhomoy Chatterjee (2018)
Semantic Scholar Logo Some data provided by SemanticScholar