A Full-range, Multi-variable, CFD-based Methodology To Identify Abnormal Near-wall Hemodynamics In A Stented Coronary Artery.

Jonathan Murphy, Fergal Boyle
Published 2010 · Medicine, Chemistry
Cite This
Download PDF
Analyze on Scholarcy
Share
The benefit of coronary stent implantation is reduced by excessive intimal hyperplasia which re-narrows the artery and the prevention of which is still a primary concern for clinicians. Abnormal hemodynamics create non-physiological viscous stress on the artery wall, one of the root causes of intimal hyperplasia following stent implantation. A methodology to comprehensively evaluate the viscous stress on the artery wall following stent implantation would be useful to evaluate a stent's hemodynamic performance.The proposed methodology employs 3D computational fluid dynamics, the variables wall shear stress (WSS), WSS gradient (WSSG), WSS angle gradient (WSSAG) and a statistical analysis to evaluate the viscous stress. The methodology is demonstrated and compared to a commonly used "threshold technique" for evaluating a stent's hemodynamic performance.It is demonstrated that the threshold technique is not adequate to fully analyse the viscous stress on the artery wall and can even be misleading. Furthermore, all three of the aforementioned variables should be considered as each provides a different perspective on the abnormalities that can arise in the arterial viscous stress.The hemodynamic performance of a stent can be assessed more comprehensively than with previously used methods by examining the arterial viscous stresses using the proposed methodology.
This paper references
Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress, Arteriosclerosis
D. N. Ku (1985)
10.1016/S0002-9149(98)00189-1
Pathobiologic responses to stenting.
Elazer R. Edelman (1998)
10.1016/S0735-1097(99)00378-2
Propensity and mechanisms of restenosis in different coronary stent designs: complementary value of the analysis of the luminal gain-loss relationship.
Javier Escaned (1999)
10.1001/jama.282.21.2035
Hemodynamic shear stress and its role in atherosclerosis.
Adel M. Malek (1999)
10.1016/1350-4533(95)00045-3
A focal stress gradient-dependent mass transfer mechanism for atherogenesis in branching arteries.
M Lei (1996)
10.1080/03091900050135013
Computational haemodynamics analysis and comparison study of arterio-venous grafts.
Philip Worth Longest (2000)
10.1016/S0735-1097(03)00119-0
Intracoronary Stenting and Angiographic Results: Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial
Adnan Kastrati (2001)
10.1152/japplphysiol.01329.2003
Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal artery.
John F. LaDisa (2004)
10.1161/01.atv.5.3.293
Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress
David N. Ku (1985)
10.1161/01.RES.53.4.502
Carotid Bifurcation Atherosclerosis: Quantitative Correlation of Plaque Localization with Flow Velocity Profiles and Wall Shear Stress
Christopher K. Zarins (1983)
Flow in stented arteries, in: Intra- and Extracorporeal Cardiovascular Fluid Dynamics, P
F. S. Henry (2003)
10.1152/japplphysiol.00872.2004
Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models.
John F. LaDisa (2005)
10.1016/s0735-1097(03)00119-0
Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial.
Jürgen Pache (2003)
10.1161/01.CIR.0000066914.95878.6D
Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent Implantation: Inhibition Through Reduction of Inflammation?
Stephane G. Carlier (2003)
10.1007/s10439-005-2499-y
Computational Study of Fluid Mechanical Disturbance Induced by Endovascular Stents
Taewon Seo (2005)
10.1111/j.1540-8183.1994.tb00469.x
Pigs, Dogs, Baboons, and Man: Lessons for Stenting from Animal Studies
Robert S. Schwartz (1994)
10.1016/0021-9150(81)90027-7
Correlation between intimal thickness and fluid shear in human arteries.
Morton H. Friedman (1981)
10.1161/01.CIR.102.12.1364
Randomized Comparison of GR-II Stent and Palmaz-Schatz Stent for Elective Treatment of Coronary Stenoses
Alexandra J Lansky (2000)
10.1115/1.2895456
Hemodynamic patterns in two models of end-to-side vascular graft anastomoses: effects of pulsatility, flow division, Reynolds number, and hood length.
Sylvia S. White (1993)
10.1186/1475-925X-4-59
Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening
John F. LaDisa (2005)
10.1115/1.1934122
Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions.
Yong Nian He (2005)
10.1016/j.jbiomech.2007.12.005
Effects of different stent designs on local hemodynamics in stented arteries.
Rossella Balossino (2008)
10.3233/BIR-2008-0497
Effects of stent geometry on local flow dynamics and resulting platelet deposition in an in vitro model.
Nandini Duraiswamy (2008)
Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis
M. Ojha (1993)
10.1615/critrevbiomedeng.v29.i1.10
Hemodynamic parameters and early intimal thickening in branching blood vessels.
Clement Kleinstreuer (2001)
10.1161/hc4701.098069
Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: comparison with intravascular ultrasound.
I k-Kyung Jang (2001)
10.1016/S0002-9149(00)01268-6
Restenosis after coronary placement of various stent types.
Adnan Kastrati (2001)
10.1109/IEMBS.2008.4650559
Assessment of the effects of increasing levels of physiological realism in the computational fluid dynamics analyses of implanted coronary stents
Jonathan Murphy (2008)
Computational fluid dynamics and stent
A. O. Frank (2002)
10.1114/1.1588654
Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation
John F. LaDisa (2004)
10.1115/1.1613674
Analysis of prolapse in cardiovascular stents: a constitutive equation for vascular tissue and finite-element modelling.
Patrick J. Prendergast (2003)
10.1115/1.1374203
The effect of proximal artery flow on the hemodynamics at the distal anastomosis of a vascular bypass graft: computational study.
S M Kute (2001)
Asymmetric flows of non-Newtonian fluids in symmetric stenosed artery
Hun Jung (2004)
10.1161/01.CIR.101.7.812
Stent and artery geometry determine intimal thickening independent of arterial injury.
Joseph M. Garasic (2000)
Blommerde et al., Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction of inflammation?, Circulation
S. G. Carlier (2003)
10.1016/0021-9290(93)90089-W
Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis model.
Maheswar Ojha (1993)
10.1046/j.1525-1594.2002.07084.x
Computational fluid dynamics and stent design.
Andreas O. Frank (2002)
10.1016/0002-9149(84)90752-5
Restenosis after percutaneous transluminal coronary angioplasty (PTCA): a report from the PTCA Registry of the National Heart, Lung, and Blood Institute.
David R Holmes (1984)
10.1161/01.CIR.91.12.2995
Endovascular stent design dictates experimental restenosis and thrombosis.
C Rogers (1995)
10.1146/annurev.fluid.39.050905.110300
Stented Artery Flow Patterns and Their Effects on the Artery Wall
Nandini Duraiswamy (2007)
Asymmetric flows of non-Newtonian fluids in a symmetric stenosed artery, Korea–Aust
H. Jung (2004)
10.1152/ajpheart.01107.2004
Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries.
John F. LaDisa (2005)
Developed pulsatile flow in a deployed coronary stent.
Rupak Kumar Banerjee (2007)
10.1115/1.3118764
Comparison of near-wall hemodynamic parameters in stented artery models.
Nandini Duraiswamy (2009)
Schoephoerster et al., Effects of stent geometry on local flow dynamics and resulting platelet deposition in an in vitro
N. Duraiswamy (2008)



This paper is referenced by
10.1115/1.4005479
The impact of simplified boundary conditions and aortic arch inclusion on CFD simulations in the mouse aorta: a comparison with mouse-specific reference data.
Bram Trachet (2011)
10.15420/VER.2018.8.2
Computational Fluid Dynamics and Aortic Dissections: Panacea or Panic?
Ian Wee (2018)
10.1102/2051-7726.2017.0001
Computational fluid dynamics in complex aortic surgery: applications, prospects and challenges
Fan Shuen Tseng (2017)
10.1002/cnm.2557
Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
David Moral Martín (2013)
10.1016/j.cmpb.2019.105243
A review study on blood in human coronary artery: Numerical approach
Rupali Pandey (2020)
10.1007/s13239-015-0219-9
Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents: A Multivariable Statistical Analysis
David Martín (2015)
Improving Cardiovascular Stent Design Using Patient-Specific Models and Shape Optimization
Timothy J. Gundert (2011)
10.1115/1.4023413
Computational Fluid Dynamics Evaluation of Equivalency in Hemodynamic Alterations Between Driver, Integrity, and Similar Stents Implanted Into an Idealized Coronary Artery
Timothy J. Gundert (2013)
10.3929/ETHZ-A-010118593
Hemodynamics and mass transfer in stented coronary arteries
Farhad Rikhtegar Nezami (2013)
10.21427/D7X75W
Oxygen Transport in Carotid and Stented Coronary Arteries
Eoin A Murphy (2017)
Title: Impact of Bioresorbable Scaffold Design Characteristics on Local Hemodynamic Forces-an ex vivo Assessment with Computational Fluid Dynamics
Imane Tarrahi (2020)
10.21427/D7532J
Numerical Prediction of the Haemodynamic Impact of Coronary Stent Implantation
Jonathan Murphy (2011)
10.1109/TBME.2012.2196275
Identification of Hemodynamically Optimal Coronary Stent Designs Based on Vessel Caliber
Timothy J. Gundert (2012)
10.3389/fbioe.2019.00366
Structural and Hemodynamic Analyses of Different Stent Structures in Curved and Stenotic Coronary Artery
Lingling Wei (2019)
Hemodynamics in the Left Coronary Artery - numerical and in vitro approaches
Erica Doutel Costa (2016)
10.1016/j.jtbi.2016.04.038
Link between deviations from Murray's Law and occurrence of low wall shear stress regions in the left coronary artery.
E. Doutel (2016)
10.1115/1.4005542
Optimization of cardiovascular stent design using computational fluid dynamics.
Timothy J. Gundert (2012)
10.1016/j.jbiomech.2017.09.016
Haemodynamic effects of incomplete stent apposition in curved coronary arteries.
Winson X Chen (2017)
10.1007/s10439-017-1806-8
Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling
Georgia S. Karanasiou (2017)
10.1016/J.BBE.2016.01.005
Numerical prediction of the effect of aortic Left Ventricular Assist Device outflow-graft anastomosis location
Rosario Mazzitelli (2016)
10.1007/s10439-015-1387-3
Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations
Susann Beier (2015)
10.1371/journal.pone.0058147
Compound Ex Vivo and In Silico Method for Hemodynamic Analysis of Stented Arteries
Farhad Rikhtegar (2013)
10.21427/D7G31Z
Sequential Structural and Fluid Dynamics Analysis of Balloon-Expandable Coronary Stents.
David D Martin (2013)
10.1016/j.medengphy.2014.05.011
Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation.
David Mingot Martín (2014)
10.1007/s00246-013-0845-7
Quantification of Local Hemodynamic Alterations Caused by Virtual Implantation of Three Commercially Available Stents for the Treatment of Aortic Coarctation
Sung Youn Kwon (2013)
Semantic Scholar Logo Some data provided by SemanticScholar