The Influence Of Co-Cr And UHMWPE Particles On Infection Persistence: An In Vivo Study In Mice.

Anton H. Hosman, Sjoerd K. Bulstra, Jelmer Sjollema, Henny C. van der Mei, Henk J. Busscher, Daniëlle Neut
Published 2012 · Medicine
Cite This
Download PDF
Analyze on Scholarcy
Share
Wear of metal-on-metal (cobalt-chromium, Co-Cr particles) and metal-on-polyethylene (ultra-high-molecular-weight polyethylene, UHMWPE particles) bearing surfaces in hip prostheses is a major problem in orthopedics. This study aimed to compare the influence of Co-Cr and UHMWPE particles on the persistence of infection. Bioluminescent Staphylococcus aureus Xen36 were injected in air pouches prepared in subcutaneous tissue of immuno-competent BALB/c mice (control), as a model for the joint space, in the absence or presence of Co-Cr or UHMWPE particles. Bioluminescence was monitored longitudinally up to 21 days, corrected for absorption and reflection by the particles and expressed relative to the bioluminescence found in the presence of staphylococci only. After termination, air pouch fluid and air pouch membrane were cultured and histologically analyzed. Bioluminescence was initially lower in mice exposed to UHMWPE particles with staphylococci than in mice injected with staphylococci only, possibly because UHMWPE particles initially stimulated a higher macrophage presence in murine air pouch membranes. For mice exposed to Co-Cr particles with staphylococci, bioluminescence was observed to be higher in two out of six animals compared to the presence of staphylococci alone. In the majority of mice, infection risk in the absence or presence of Co-Cr and UHMWPE particles appeared similar, assuming that the longevity of an elevated bioluminescence is indicative of a higher infection risk. However, the presence of Co-Cr particles yielded a higher bioluminescence in two out of six mice, possibly because the macrophage degradative function was hampered by the presence of Co-Cr particles.
This paper references
10.1093/infdis/146.4.487
Pathogenesis of foreign body infection: description and characteristics of an animal model.
Werner Zimmerli (1982)
10.1128/IAI.71.2.882-890.2003
Direct Continuous Method for Monitoring Biofilm Infection in a Mouse Model
Jagath L. Kadurugamuwa (2003)
10.1002/path.1711340205
The formation of a structure with the features of synovial lining by subcutaneous injection of air: an in vivo tissue culture system.
John C. Edwards (1981)
10.2106/JBJS.D.02937
The impact of infection after total hip arthroplasty on hospital and surgeon resource utilization.
Kevin John Bozic (2005)
10.1086/315369
Biomaterial-associated persistence of Staphylococcus epidermidis in pericatheter macrophages.
Jaap Jan Boelens (2000)
10.1016/j.arth.2008.01.134
Highly crosslinked vs conventional polyethylene particles: relative in vivo inflammatory response.
Richard Lynn Illgen (2009)
10.1615/AtomizSpr.v3.i3.40
Multiple scattering and size distribution effects on the performance of a laser diffraction particle sizer
Tuomas Paloposki (1993)
10.1172/JCI111305
Pathogenesis of foreign body infection. Evidence for a local granulocyte defect.
Werner Zimmerli (1984)
10.1002/jbm.a.31922
Metal-on-metal bearings in total hip arthroplasties: Influence of cobalt and chromium ions on bacterial growth and biofilm formation.
Anton H. Hosman (2009)
10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M
Metal wear particle characterization from metal on metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles.
P F Doorn (1998)
10.1128/IAI.68.6.3594-3600.2000
Monitoring Bioluminescent Staphylococcus aureusInfections in Living Mice Using a Novel luxABCDEConstruct
Kevin P. Francis (2000)
10.1097/01.blo.0000150311.33227.b1
Particles of All Sizes Provoke Inflammatory Responses In Vivo
Stefan Zysk (2005)
10.1302/0301-620X.89B12.19714
The effect of metal ions in solution on bacterial growth compared with wear particles from hip replacements.
H. A. Anwar (2007)
10.1016/S0142-9612(01)00134-X
Inflammatory responses to orthopaedic biomaterials in the murine air pouch.
Paul H. Wooley (2002)
10.2106/00004623-198567080-00015
The influence of skeletal implants on incidence of infection. Experiments in a canine model.
W Petty (1985)
10.1371/journal.pone.0012580
A Mouse Model of Post-Arthroplasty Staphylococcus aureus Joint Infection to Evaluate In Vivo the Efficacy of Antimicrobial Implant Coatings
Nicholas M Bernthal (2010)
10.1016/j.arth.2004.08.011
Metal-on-Metal total hip replacement: what does the literature say?
John H. Dumbleton (2005)
10.1002/jbm.a.32301
In vivo production of nanosized metal wear debris formed by tribochemical reaction as confirmed by high-resolution TEM and XPS analyses.
Ingrid Milošev (2009)
10.1302/0301-620X.89B7.19972
Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty.
P A Vendittoli (2007)
10.1016/j.arth.2006.02.083
Activity level in young patients with primary total hip arthroplasty: a 5-year minimum follow-up.
V. Franklin Sechriest (2007)
10.2106/00004623-200004000-00002
Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement*
Robert M. Urban (2000)
10.1016/j.biomaterials.2010.11.016
The potential role of cobalt ions released from metal prosthesis on the inhibition of Hv1 proton channels and the decrease in Staphyloccocus epidermidis killing by human neutrophils.
Samira Daou (2011)
10.1002/jbm.1068
The wear pattern in metal-on-metal hip prostheses.
H L Anissian (2001)
10.1097/01.blo.0000149995.84350.d7
Metal-on-metal total hip replacement.
Maurício Silva (2005)
10.1002/jbm.b.31048
Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty.
Yukihide Minoda (2008)
10.1002/jbm.a.10368
Morphological characteristics of total joint arthroplasty-derived ultra-high molecular weight polyethylene (UHMWPE) wear debris that provoke inflammation in a murine model of inflammation.
Allison L. Sieving (2003)
10.1097/00003086-199605000-00008
The Immune Response to Implant Materials in Humans
Paul H. Wooley (1996)
10.1016/S0142-9612(98)00140-9
Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro.
Tara R. Green (1998)
10.1097/SLA.0b013e3181b61d9a
In Vivo Evaluation of Bacterial Infection Involving Morphologically Different Surgical Meshes
A F Engelsman (2010)
10.1007/s11999-007-0045-y
THA Using Metal-on-Metal Articulation in Active Patients Younger Than 50 Years
Christian P Delaunay (2008)
10.1016/j.arth.2004.09.011
Induction of apoptosis and necrosis by metal ions in vitro.
Olga L. Huk (2004)



This paper is referenced by
Supporting Information 2 Extrapolation of Responses to Human Health
Amy K. Madl (2014)
10.1111/j.1469-0691.2012.04002.x
Influence of material on the development of device-associated infections.
Edward T J Rochford (2012)
10.2106/JBJS.18.00425
In Vivo Bioluminescence Imaging in a Rabbit Model of Orthopaedic Implant-Associated Infection to Monitor Efficacy of an Antibiotic-Releasing Coating
Robert Miller (2019)
Synthesis, characterisation and corrosion studies of CoCrMo nanoparticles for hip implants
Thiago A. Simões (2015)
10.1016/J.JEURCERAMSOC.2017.10.008
Reduced bacterial adhesion on ceramics used for arthroplasty applications
Rita Sorrentino (2018)
10.1002/jbm.b.33095
Effect of erythromycin-doped calcium polyphosphate scaffold composite in a mouse pouch infection model.
Weiping Ren (2014)
10.1016/j.nano.2015.02.006
Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants Part II: Importance of physicochemical properties and dose in animal and in vitro studies as a basis for risk assessment.
Amy K. Madl (2015)
10.1002/bdr2.1352
Applications and challenges of using 3D printed implants for the treatment of birth defects.
Sameera Wickramasinghe (2018)
10.1002/advs.201700892
Nanoscience‐Based Strategies to Engineer Antimicrobial Surfaces
Serena Rigo (2018)
10.1039/C7TB01372H
Toxicity and oxidative stress responses induced by nano- and micro-CoCrMo particles
Andrea L. Armstead (2017)
10.1007/s40735-018-0188-2
SMART Biosensor for Early Diagnostic Detection of Metal Ion Release in Orthopedic Patients: Initial Outcome
Mathew T. Mathew (2018)
10.1080/14686996.2017.1348872
Understanding biomaterial-tissue interface quality: combined in vitro evaluation
Michael Gasik (2017)
Semantic Scholar Logo Some data provided by SemanticScholar