Online citations, reference lists, and bibliographies.

False Aneurysm Of The Common Digital Artery. Is Reconstruction With An Arterial Graft Worth The Efforts? A Case Report.

S. Lucchina, A. Nistor, H. Stricker, C. Fusetti
Published 2011 · Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
False aneurysms in the hand are rare. A false aneurysm of the common digital artery in the palm for the second and third finger is reported, illustrating our experience with arterial graft reconstruction after excision as a valid alternative surgical therapy to a vein graft, when ligation or end-to-end anastomosis are not indicated or feasible. The superficial palmar branch of the radial artery was chosen as donor vessel based on the similarity in vessel diameter and wall thickness to the common digital arteries. Ease of harvesting and performing the microvascular anastomosis using an arterial graft allows for a viable reconstruction after false aneurysm excision in the palm.
This paper references
Traumatic Aneurysm of the Radial Artery.
F. M. Payne (1941)
10.1016/0002-9610(62)90287-8
True aneurysms of traumatic origin in the palm.
J. Smith (1962)
10.1097/TA.0b013e31816a4eb7
Free flap from the superficial palmar branch of the radial artery (SPBRA flap) for finger reconstruction.
Tzu-Peng Lee (2009)
10.1055/s-2007-1006720
Aneurysms of the palmar arch and a proper digital artery: case report and literature review.
M. Lanzetta (1992)
Digital nerve compression secondary to palmar aneurysm.
R. O'connor (1972)
10.1097/00005373-197606000-00018
VASCULAR SYSTEM: Traumatic arteriovenous fistulas and false aneurysms, a review of 558 lesions
N. Rich (1976)
10.1016/S0266-7681(02)00279-6
Vascular Anatomy of the Palmar Surfaces of the Distal Radius And Ulna: Its Relevance to Pedicled Bone Grafts at the Distal Palmar Forearm
M. Haerle (2003)
10.1097/00003086-200102000-00007
Arterial Patterns of the Deep and Superficial Palmar Arches
H. Gellman (2001)
10.1097/00000658-198106000-00004
Evaluation and treatment of chronic digital ischemia.
E. F. Wilgis (1981)
10.1097/00005373-197005000-00001
Acute arterial injuries in Vietnam: 1,000 cases.
N. Rich (1970)
10.1201/b13308-14
Vascular disorders.
W. G. Hardy (1968)
10.1016/S0072-968X(77)80033-8
False Aneurysm of the Ulnar Artery
M. Milling (1977)
10.1001/archsurg.1973.01350160166028
Aneurysms of the hand.
H. E. Kleinert (1973)
10.1016/J.MAIN.2009.12.004
Influence de la perméabilite de l'artère digitale palmaire sur la récuperation nerveuse dans les lésions des nerfs digitaux palmaires
Mathilde Piquet (2010)
Ulnar artery thrombosis.
L. Koman (1985)
10.1097/00006534-196201000-00028
Arterial patterns in the hand based upon a study of 650 specimens.
S. Coleman (1961)
10.1097/00006534-199701000-00018
Vascular and Neural Anatomy of the Thenar Area of the Hand: Its Surgical Applications
S. Omokawa (1997)
10.1056/NEJMOA040982
A randomized comparison of radial-artery and saphenous-vein coronary bypass grafts.
N. Desai (2004)
10.1097/BTH.0b013e3181ac9183
The glabrous palmar flap: the new free or reversed pedicled palmar fasciocutaneous flap for volar hand reconstruction.
J. Orbay (2009)
10.2106/00004623-197355010-00012
True and false traumatic aneurysms in the hand.
D. Green (1973)
10.1016/j.main.2009.12.004
[Influence of palmar digital artery patency on neurological recovery of palmar digital nerve lesions].
M Piquet (2010)
10.1016/J.JHSA.2004.05.009
Treatment of radial and ulnar artery pseudoaneurysms using percutaneous thrombin injection.
E. Komorowska-Timek (2004)
10.1097/00005373-196507000-00001
THROMBOSIS OF THE PALMAR ARTERIAL ARCH AND ITS TRIBUTARIES: ETIOLOGY AND NEWER CONCEPTS IN TREATMENT.
H. E. Kleinert (1965)
10.1016/S0363-5023(82)80113-5
True aneurysm of digital artery.
C. D. Layman (1982)
10.1097/00006534-197106000-00032
Traumatic aneurysm of the hand.
E. Mays (1970)
10.1016/0072-968X(73)90034-X
Traumatic Aneurysm of the Digital Artery A Complication of Fasciectomy
J. Hueston (1973)
10.1002/micr.20723
Acute digital ischemia: a neglected microsurgical emergency. Report of 17 patients and literature review.
F. Leclère (2010)
10.1016/0266-7681_88_90110-6
Aneurysm of a Common Digital Artery: Resection and Vein Graft
G. Tyler (1988)
10.1016/S0003-4975(00)02285-2
The radial artery versus the saphenous vein graft in contemporary CABG: a case-matched study.
G. Cohen (2001)
10.1097/00003086-197203000-00028
Digital Nerve Compression Secondary to Palmar Aneurysm
O'Connor Rl (1972)
10.1016/S0363-5023(87)80158-2
Aneurysms of the upper extremity.
P. Ho (1987)
10.1016/S0363-5023(97)80169-4
Aneurysms of the digital arteries: a case report and literature review.
M. Abouzahr (1997)
A randomized comparison of radialartery and saphenousvein coronary bypass grafts
ND Desai (2004)
10.1016/S0072-968X(77)80018-1
False Aneurysm of the Digital Artery
A. Baruch (1977)
A study of the superficial palmar arteries using the Doppler Ultrasonic Flowmeter.
M. al-Turk (1984)
10.1016/s0003-4975(10)65825-0
The aorta-to-coronary radial artery bypass graft. A technique avoiding pathological changes in grafts.
A. Carpentier (1973)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar