Online citations, reference lists, and bibliographies.

A-Si:H TFT-Based Active Matrix Flat-Panel Imagers For Medical X-Ray Applications

L. Antonuk
Published 2004 · Materials Science

Cite This
Download PDF
Analyze on Scholarcy
Share
This paper references
10.1117/12.237811
High-resolution amorphous silicon image sensor
T. Graeve (1996)
10.1557/PROC-336-855
A Large Area, High-Resolution a-Si:H Array for X-Ray Imaging
L. Antonuk (1994)
10.1118/1.1374244
Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device.
B. McCurdy (2001)
10.1557/PROC-192-441
Amorphous Silicon Sensor Arrays for Radiation Imaging
R. Street (1990)
10.1117/12.430887
Performance of a flat-panel cardiac detector
P. Granfors (2001)
10.1117/12.430921
Filtered gain calibration and its effect on frequency-dependent DQE and image quality in Se-based general radiography and full-field mammographic digital imaging
Denny L. Y. Lee (2001)
10.1557/PROC-297-945
Considerations for high frame rate operation of two-dimensional a-Si: H imaging arrays
L. Antonuk (1993)
10.1117/12.480251
Measurements on a full-field digital mammography system with a photon counting crystalline silicon detector
M. Lundqvist (2003)
10.1117/12.237812
Amorphous silicon x-ray image sensor
J. Chabbal (1996)
10.1117/12.465594
Progress report on the performance of real-time selenium flat-panel detectors for direct x-ray imaging
O. Tousignant (2002)
10.1118/1.598245
X-ray imaging using amorphous selenium: determination of Swank factor by pulse height spectroscopy.
I. Blevis (1998)
10.1080/13642819108205566
Long-time transient conduction in a-Si:H p─i─n devices
R. Street (1991)
10.1117/12.479995
Digital indirect-detection x-ray imagers with microlens focusing: effects of Fresnel reflections from the microlens layer
N. Petrick (2003)
10.1117/12.208340
Large-area flat-panel amorphous silicon imagers
L. Antonuk (1995)
10.1117/12.430858
Comparative study of Pbl2 and Hgl2 as direct detector materials for high-resolution x-ray image sensors
R. Street (2001)
10.1557/PROC-219-537
Characteristics of a-Si Pixel Arrays for Radiation Imaging
I. Fujieda (1991)
10.1557/PROC-258-1145
Large Area 2-Dimensional a-Si:H Imaging Arrays
R. Street (1992)
10.1007/978-3-662-04141-3
Technology and Applications of Amorphous Silicon
R. Street (2000)
10.1117/12.484071
Evaluation of novel direct- and indirect-detection active matrix flat-panel imagers (AMFPIs) for mammography
Y. El‐Mohri (2003)
10.1364/JOSAA.4.000895
Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms.
M. Rabbani (1987)
10.1118/1.597918
Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation.
L. Antonuk (1997)
10.1118/1.598741
Analysis of the detective quantum efficiency of a developmental detector for digital mammography.
M. B. Williams (1999)
10.1148/radiology.148.1.6856847
Digital radiography of the chest: design features and considerations for a prototype unit.
M. Tesic (1983)
10.1557/PROC-297-939
2D Image Sensing Arrays with NIP Diodes
C. V. Berkel (1993)
10.1557/PROC-258-1069
Factors Affecting Image Quality for Megavoltage and Diagnostic X-Ray a-Si:H Imaging Arrays.
L. Antonuk (1992)
10.1117/12.384491
Optimization of key building blocks for a large-area radiographic and fluoroscopic dynamic digital x-ray detector based on a-Si:H/CsI:Tl flat panel technology
Thomas Ducourant (2000)
10.1117/12.317051
Selenium direct-converter structure for static and dynamic x-ray detection in medical imaging applications
Brad T. Polischuk (1998)
10.1118/1.598243
Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.
J. Siewerdsen (1998)
10.1117/12.384520
Radiological x-ray response of polycrystalline mercuric-iodide detectors
M. Schieber (2000)
10.1063/1.1662918
Absorption and noise in x‐ray phosphors
R. K. Swank (1973)
10.1117/12.59387
Development of thin-film flat-panel arrays for diagnostic and radiotherapy imaging
L. Antonuk (1992)
10.1118/1.597599
X-ray imaging with amorphous selenium: detective quantum efficiency of photoconductive receptors for digital mammography.
R. Fahrig (1995)
10.1117/12.480227
Mercuric iodide and lead iodide x-ray detectors for radiographic and fluoroscopic medical imaging
G. Zentai (2003)
10.1118/1.596802
Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays.
L. Antonuk (1992)
10.1016/S0360-3016(98)00210-7
Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging.
L. Antonuk (1998)
10.1117/12.349477
Development and evaluation of a large-area selenium-based flat-panel detector for real-time radiography and fluoroscopy
A. Tsukamoto (1999)
10.1016/S0168-9002(01)02129-5
Design and performance of a low noise, 128-channel ASIC preamplifier for readout of active matrix flat-panel imaging arrays
M. Maolinbay (2002)
10.1118/1.1538233
Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.
W. Zhao (2003)
10.1016/S0040-6090(96)09340-6
Amorphous silicon sensor arrays for X-ray and document imaging
R. Street (1997)
10.1063/1.1323529
Simulated and measured data-line parasitic capacitance of amorphous silicon large-area image sensor arrays
M. Mulato (2001)
10.1117/12.154581
Digital radiology using self-scanned readout of amorphous selenium
W. Zhao (1993)
10.1088/0031-9155/37/5/010
First x-ray images with a double-sided microstrips silicon crystal. A novel detector for digital radiography?
B. Alfano (1992)
10.1118/1.597389
Image quality of a digital chest radiography system based on a selenium detector.
U. Neitzel (1994)
10.1117/12.18803
Conversion noise measurement for front and back x-ray intensifying screens
D. Trauernicht (1990)
10.1118/1.598895
Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.
S. Vedantham (2000)
10.1117/12.953192
Detective Quantum Efficiency Of Selected Mammographic Screen-Film Combinations
P. Bunch (1989)
10.1117/12.317039
Development of a selenium-based flat-panel detector for real-time radiography and fluoroscopy
A. Tsukamoto (1998)
10.1118/1.1507781
Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography.
M. Båth (2002)
10.1118/1.598955
Characterization of a fluoroscopic imaging system for kV and MV radiography.
D. G. Drake (2000)
10.1117/12.384481
DQE(f) of an amorphous-silicon flat-panel x-ray detector: detector parameter influences and measurement methodology
P. Granfors (2000)
10.1118/1.1689014
Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.
S. Vedantham (2004)
10.1148/radiology.154.3.3969486
Digital chest radiography: performance evaluation of a prototype unit.
G. Barnes (1985)
10.1016/0022-3093(93)91115-J
Two dimensional image sensors based on amorphous silicon alloy p-i-n diodes
G. Cesare (1993)
10.1117/12.480010
Performance of advanced a-Si/CsI-based flat-panel x-ray detectors for mammography
D. Albagli (2003)
10.1016/0168-9002(90)90764-W
Radiation damage studies of amorphous-silicon photodiode sensors for applications in radiotherapy X-ray imaging
L. Antonuk (1990)
10.1118/1.597628
X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology.
W. Zhao (1995)
10.1109/23.322874
A data acquisition system for flat-panel imaging arrays
E. Morton (1993)
10.1016/S0022-3093(99)00925-4
Lateral conduction in structured amorphous silicon p+–i–n+ photodiodes
F. Lemmi (2000)
10.1117/12.317006
Large-area 97-μm pitch indirect-detection active-matrix flat-panel imager (AMFPI)
L. Antonuk (1998)
10.1117/12.430917
40 x 30 cm flat-panel imager for angiography, R&F, and cone-beam CT applications
R. Colbeth (2001)
10.1117/12.206513
Amorphous silicon image sensor for x-ray applications
T. Graeve (1995)
10.1118/1.1561285
An experimental comparison of detector performance for direct and indirect digital radiography systems.
E. Samei (2003)
10.1118/1.596447
Origins of flare in x-ray image intensifiers.
R. Luhta (1990)
10.1117/12.384485
Direct selenium x-ray detector for fluoroscopy, R&F, and radiography
M. Choquette (2000)
10.1117/12.480254
Active pixel image sensor for large-area medical imaging
K. Karim (2003)
10.1117/12.174247
High-resolution, high-frame-rate, flat-panel TFT array for digital x-ray imaging
L. Antonuk (1994)
10.1109/16.628824
CMOS image sensors: electronic camera-on-a-chip
E. R. Fossum (1997)
10.1117/12.349546
Signal and noise analysis using transmission line model for larger-area flat-panel x-ray imaging sensors
Zhong Shou Huang (1999)
10.1117/12.154598
Large area, flat-panel a-Si:H arrays for x-ray imaging
L. Antonuk (1993)
10.1063/1.103475
Thermal generation currents in hydrogenated amorphous silicon p - i - n structures
R. Street (1990)
10.1007/0-306-47119-1
Solid-State Imaging with Charge-Coupled Devices
A. Theuwissen (1995)
10.1557/PROC-715-A4.1
Large Area Electronics for Flat Panel Imagers Progress and Challenges
J. Lu (2002)
10.1017/CBO9780511525247
Hydrogenated amorphous silicon: Index
R. Street (1991)
10.1007/s003300000795
Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
Svenja P. Hennigs (2001)
10.1117/12.349529
High-resolution high fill factor a-Si:H sensor arrays for medical imaging
J. Rahn (1999)
10.1117/12.317040
Dynamic x-ray imaging system based on an amorphous silicon thin-film array
N. Jung (1998)
10.1117/12.59391
Large-area solid state detector for radiology using amorphous selenium
Wei Zhao (1992)
10.1118/1.597919
Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology.
J. Siewerdsen (1997)
10.1118/1.595556
Detective quantum efficiency of x-ray image intensifiers: comparison of scintillation spectrum and rms methods.
J. Rowlands (1984)
10.1063/1.1370111
Crosstalk and lateral conduction effects in continuous-sensor amorphous silicon imagers
M. Mulato (2001)
10.1063/1.1436298
Comparison of PbI2 and HgI2 for direct detection active matrix x-ray image sensors
R. Street (2002)
10.1117/12.317037
Flat-panel imaging system for fluoroscopy applications
R. Colbeth (1998)
10.1117/12.939356
Imaging And Noise Limitations Of Cesium Iodide X-Ray Image Intensifiers
J. Rowlands (1984)
10.1117/12.317045
Novel large-area MIS-type x-ray image sensor for digital radiography
T. Kameshima (1998)
10.1118/1.596819
Charge-coupled device detector: performance considerations and potential for small-field mammographic imaging applications.
A. Karellas (1992)
10.1117/12.273992
Degradation of the detective quantum efficiency due to a nonunity detector fill factor
I. Cunningham (1997)
10.1016/S0360-3016(02)02884-5
Flat-panel cone-beam computed tomography for image-guided radiation therapy.
D. Jaffray (2002)
Radiology in Medical Diagnostics: Evolution of X-Ray Applications 1895-1995
G. Rosenbusch (1995)
10.1117/12.317054
Thin-film transistor array technology for high-performance direct-conversion x-ray sensors
W. den Boer (1998)
10.1117/12.430913
Temporal artifacts in flat dynamic x-ray detectors
M. Overdick (2001)
10.1109/NSSMIC.2000.948998
Evaluation of a photon counting X-ray imaging system
M. Lundqvist (2000)
10.1118/1.595357
Absorption and noise in cesium iodide x-ray image intensifiers.
J. Rowlands (1983)
10.1118/1.598229
Digital radiology using active matrix readout of amorphous selenium: detectors with high voltage protection.
W. Zhao (1998)
10.1117/12.465615
Direct-conversion imaging panel having a charge transport layer with controlled time constant
Denny L. Y. Lee (2002)
10.1148/radiology.138.3.6970372
Radiological imaging--2000 A.D.
M. Capp (1981)
10.1063/1.1481788
Flat panel imagers with pixel level amplifiers based on polycrystalline silicon thin-film transistor technology
J. Lu (2002)
10.1117/12.349504
X-ray imaging using lead iodide as a semiconductor detector
R. Street (1999)
10.1117/12.274000
Prototype amorphous silicon array based radiotherapy portal imager
D. G. Drake (1997)
10.1016/S0168-9002(99)00900-6
A programmable, low noise, multichannel ASIC for readout of pixelated amorphous silicon arrays
R. Yarema (2000)
10.1016/S0168-9002(99)00275-2
An asynchronous, pipelined, electronic acquisition system for Active Matrix Flat-Panel Imagers (AMFPIs)
Weidong Huang (1999)
10.1117/12.480131
Imaging performance of an amorphous selenium flat-panel detector for digital fluoroscopy
Dylan C. Hunt (2003)
10.1118/1.598657
A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager.
J. Siewerdsen (1999)
10.1117/12.208342
New digital detector for projection radiography
Denny L. Y. Lee (1995)
10.1557/PROC-467-863
Amorphous Silicon Photodiode-Thin Film Transistor Image Sensor with Diode on Top Structure
M. Powell (1997)
10.5860/choice.26-0676
Encyclopedia of Medical Devices and Instrumentation
J. Webster (1988)
10.1117/12.384516
High-resolution direct-detection x-ray imagers
R. Street (2000)
10.1117/12.43435
Signal-to-noise performance in cesium iodide x-ray fluorescent screens
Walter Hillen (1991)
10.1118/1.597401
A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.
I. A. Cunningham (1994)
10.1117/12.317049
New CsI/a-Si 17" x 17" x-ray flat-panel detector provides superior detectivity and immediate direct digital output for general radiography systems
Christophe Chaussat (1998)
10.1117/12.174248
Fluoroscopic x-ray imaging with amorphous silicon thin-film arrays
U. Schiebel (1994)
10.1557/PROC-487-399
Amorphous Silicon Sensor Arrays for X-Ray and Document Imaging
R. Street (1997)
10.1117/12.465557
Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors
Wei Zhao (2002)
10.1118/1.598831
Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.
L. Antonuk (2000)
10.1007/BF00617183
The effect ofγ-irradiation on amorphous silicon field effect transistors
I. French (1983)
10.1117/12.479969
Image quality of digital radiography using flat detector technology
Thomas Ducourant (2003)
10.1117/12.349518
Direct conversion detector for digital mammography
Brad T. Polischuk (1999)
10.1118/1.597668
Radiation damage of amorphous silicon, thin-film, field-effect transistors.
J. Boudry (1996)
10.1117/12.208343
Digital radiology using self-scanned readout of amorphous selenium: design considerations for mammography
Wei Zhao (1995)
10.1118/1.598649
Relative dosimetry using active matrix flat-panel imager (AMFPI) technology.
Y. El‐Mohri (1999)
INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS.
T. Fu (1984)
10.1118/1.1513157
X-ray imaging with amorphous selenium: X-ray to charge conversion gain and avalanche multiplication gain.
D. Hunt (2002)
10.1557/PROC-258-1127
Amorphous Silicon Image Sensor Arrays
M. Powell (1992)
10.1117/12.430873
Performance of a real-time selenium-based x-ray detector for fluoroscopy
M. Choquette (2001)
10.1117/12.384511
Experimental evaluation of a-Se and CdTe flat-panel x-ray detectors for digital radiography and fluoroscopy
Susumu Adachi (2000)
10.1117/12.384492
Development of a novel high-resolution direct conversion x-ray detector
E. L. Gingold (2000)
10.1117/12.939357
Noise Power Spectrum, MTF, And DQE Of Photoelectronic Radiographic Systems
T. Fu (1984)
10.1117/12.957129
Computer Electronic Radiography For Early Detection Of Vascular Disease
D. Sashin (1979)
10.1117/12.317017
Improved imaging performance of a 14"x17" direct radiography system using a Se/TFT detector
Denny L. Y. Lee (1998)
10.1118/1.596335
Effect of finite phosphor thickness on detective quantum efficiency.
R. Nishikawa (1989)
10.1109/23.159759
Radiation imaging with 2D a-Si sensor arrays
I. Fujieda (1991)
10.1118/1.598572
Digital radiology using active matrix readout: amplified pixel detector array for fluoroscopy.
N. Matsuura (1999)
10.1118/1.597511
Toward consensus on quantitative assessment of medical imaging systems.
C. Metz (1995)
10.1109/23.322792
Radiation damage of amorphous silicon photodiode sensors
J. Boudry (1994)
10.1118/1.599010
Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications.
P. Granfors (2000)
10.1117/12.465584
Approaching the theoretical x-ray sensitivity with Hgl2 direct detection image sensors
R. Street (2002)
10.1109/23.159761
Radiation response characteristics of amorphous silicon arrays for megavoltage radiotherapy imaging
L.E. Antonuk (1991)
10.1118/1.1286721
Additive noise properties of active matrix flat-panel imagers.
M. Maolinbay (2000)
10.1118/1.1585051
System performance of a prototype flat-panel imager operated under mammographic conditions.
K. Jee (2003)
10.1117/12.465568
Characterization of a full-field digital mammography detector based on direct x-ray conversion in selenium
Jeffrey Yorker (2002)
10.1148/radiology.192.3.624
A Century of X-rays and Radioactivity in Medicine
H. Jones (1994)
10.1117/12.430879
Evaluation of direct detection and indirect detection active matrix flat-panel imagers (AMFPIs) for digital mammography
K. Jee (2001)



This paper is referenced by
10.1002/mp.13791
Comparison of CsI:Tl and Gd2 O2 S:Tb indirect flat panel detector x-ray imaging performance in front- and back-irradiation geometries.
Adrian Howansky (2019)
10.1148/RADIOL.2381041602
Evolving and experimental technologies in medical imaging.
A. B. Wolbarst (2006)
10.1117/12.2043804
Initial steps toward the realization of large area arrays of single photon counting pixels based on polycrystalline silicon TFTs
A. Liang (2014)
10.1063/1.2179149
Effects of x-ray irradiation on polycrystalline silicon, thin-film transistors
Y. Li (2006)
Evolving and Experimental Technologies in Medical Imaging 1
Anthony Brinton Wolbarst (2004)
10.1117/12.771406
Exploration of the potential performance of polycrystalline silicon-based active matrix flat-panel imagers incorporating active pixel sensor architectures
L. Antonuk (2008)
10.1118/1.3416924
Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging.
Qihua Zhao (2010)
10.1088/0031-9155/57/16/5343
Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers.
Langechuan Liu (2012)
10.1117/12.713707
Quantitative exploration of performance enhancements offered by active matrix x-ray imagers fabricated on plastic substrates
L. Antonuk (2007)
10.1016/J.SSE.2017.02.006
Study of current-mode active pixel sensor circuits using amorphous InSnZnO thin-film transistor for 50-μm pixel-pitch indirect X-ray imagers
M. Cheng (2017)
10.1002/mp.12257
Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors
M. Koniczek (2017)
10.1109/TNS.2004.843135
Examination of PbI/sub 2/ and HgI/sub 2/ photoconductive materials for direct detection, active matrix, flat-panel imagers for diagnostic X-ray imaging
Yixiu Kang (2005)
10.1088/0031-9155/58/3/703
Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging.
Hao Jiang (2013)
10.1007/978-3-642-34076-5_8
Characterization of Radiation Detectors (Scintillators) Used in Nuclear Medicine
Tapan Kumar Das Gupta (2013)
10.1002/mp.13128
Theoretical investigation of the count rate capabilities of in‐pixel amplifiers for photon counting arrays based on polycrystalline silicon TFTs
A. Liang (2018)
10.1118/1.3049602
An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays.
L. Antonuk (2009)
10.1088/0031-9155/50/12/012
Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.
Z. Su (2005)
10.1118/1.2008428
Indirect flat-panel detector with avalanche gain: Fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).
W. Zhao (2005)
10.1118/1.2403967
Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography.
Y. El‐Mohri (2007)
10.1117/12.537038
Systematic development of input-quantum-limited fluoroscopic imagers based on active-matrix flat-panel technology
L. Antonuk (2004)
10.1002/3527600434.EAP177.PUB3
Biomedical Imaging Technologies
William R. Hendee (2009)
Semantic Scholar Logo Some data provided by SemanticScholar