Online citations, reference lists, and bibliographies.

Selection Of Coronary Stents.

Antonio Colombo, Goran Stanković, Jeffrey W. Moses
Published 2002 · Medicine
Cite This
Download PDF
Analyze on Scholarcy
Share
In clinical practice, the operator must decide which stent is most appropriate for the patient. This article focuses on the features of stent design that make a specific stent more or less suitable for a particular type of lesion or anatomy: the "average" coronary lesion, the lesion situated on a curve, the ostial lesion, the bifurcational lesion, the lesion located at the left main stem, the calcified lesion, the chronic total occlusion, the small vessel, the saphenous vein graft, acute or threatened vessel closure, and special situations such as coronary aneurysms and perforations.
This paper references
An in-vitro assessment of stent geometry for bifurcation lesions after kissing balloon inflation (abstr)
G Stankovic (2001)
10.1016/S0002-9149(99)80040-X
Acute clinical and angiographic results with the new AVE Micro coronary stent in bailout management.
Yukio Ozaki (1995)
10.1016/0735-1097(96)00155-6
Short- and long-term clinical and quantitative angiographic results with the new, less shortening Wallstent for vessel reconstruction in chronic total occlusion: a quantitative angiographic study.
Yukio Ozaki (1996)
10.1016/S0735-1097(02)80251-0
Safety and performance of a paclitaxel-eluting stent for the treatment of in-stent restenosis: preliminary results of the taxus III trial
Eberhard Grube (2002)
The NUGGET trial (NIR Ultimate Gold-Gilded Equivalency Trial): 6 months post procedure safety and efficacy results (abstr)
S Silber (2001)
10.1016/S0140-6736(00)03262-1
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Ralf Koester (2000)
10.1161/01.CIR.90.6.2716
Four‐Year Experience With Palmaz‐Schatz Stenting in Coronary Angioplasty Complicated by Dissection With Threatened or Present Vessel Closure
Albert Schoemig (1994)
Stent reduces restenosis in small vessels: results of the RAP study (abstr)
E Garcia (2001)
10.1161/01.CIR.103.2.192
Lack of Neointimal Proliferation After Implantation of Sirolimus-Coated Stents in Human Coronary Arteries A Quantitative Coronary Angiography and Three-Dimensional Intravascular Ultrasound Study
Jose Eduardo M. Sousa (2001)
10.1016/0002-9149(94)90822-2
Results of coronary stenting of ostial lesions.
P G Zampieri (1994)
Stent Placement Compared With Balloon Angioplasty for Small Coronary Arteries
RenéKoning (2001)
10.1161/hc4201.098056
Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents: One-Year Angiographic and Intravascular Ultrasound Follow-Up
Jose Eduardo M. Sousa (2001)
TAXUS 1 prospective, randomized, double blind comparison of NIRXTM stents coated with paclitaxel in a polymer carrier in de novo coronary lesions compared with uncoated controls (abstr)
E Grube (2001)
10.1016/S0140-6736(95)91066-2
Percutaneous implantation of autologous vein graft stent for treatment of coronary artery disease
Christodoulos Stefanadis (1995)
10.1002/(SICI)1097-0304(199607)38:3<229::AID-CCD1>3.0.CO;2-A
Coronary plaque morphology affects stent deployment: assessment by intracoronary ultrasound.
Detlev Albrecht (1996)
10.1002/(SICI)1522-726X(199904)46:4<463::AID-CCD17>3.0.CO;2-I
Treatment of a coronary aneurysm with a new polytetrafluoethylene-coated stent: a case report.
Carlo di Mario (1999)
10.1002/(SICI)1097-0304(199606)38:2<159::AID-CCD8>3.0.CO;2-8
Autologous vein graft-coated stent for treatment of coronary artery disease.
C I Stefanadis (1996)
10.1161/01.CIR.100.3.236
Primary stenting versus balloon angioplasty in occluded coronary arteries: the Total Occlusion Study of Canada (TOSCA).
Christopher E H Buller (1999)
10.1016/S0735-1097(96)00349-X
Stenting in Chronic Coronary Occlusion (SICCO): a randomized, controlled trial of adding stent implantation after successful angioplasty.
Per Anton Sirnes (1996)
Lon - gitudinal straightening effect of stents is an additional predictor for major adverse cardiac events
M Gyongyosi (2000)
10.1161/01.CIR.0000012783.63093.0C
Randomized Trial of a Distal Embolic Protection Device During Percutaneous Intervention of Saphenous Vein Aorto-Coronary Bypass Grafts
Donald S. Baim (2002)
10.1161/01.CIR.102.17.2024
Treatment of Aortocoronary Vein Graft Lesions With Membrane-Covered Stents: A Multicenter Surveillance Trial
Stephan Baldus (2000)
10.1016/S0735-1097(98)00404-5
Angiographic and intravascular ultrasound predictors of in-stent restenosis.
Shunji Kasaoka (1998)
10.1161/01.CIR.86.3.812
Emergent Use of Balloon‐Expandable Coronary Artery Stenting for Failed Percutaneous Transluminal Coronary Angioplasty
Howard C Herrmann (1992)
10.1161/01.CIR.86.6.1827
The Importance of Acute Luminal Diameter in Determining Restenosis After Coronary Atherectomy or Stenting
Richard E. Kuntz (1992)
10.1016/s0002-9149(00)01307-2
Final results of a randomized trial comparing the NIR stent to the Palmaz-Schatz stent for narrowings in native coronary arteries.
Donald S. Baim (2001)
10.1002/(SICI)1522-726X(199906)47:2<258::AID-CCD27>3.0.CO;2-C
Stent deformation following simulated side-branch dilatation: a comparison of five stent designs.
John A Ormiston (1999)
10.1056/NEJM199408253310801
A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group.
P. W. Serruys (1994)
A RANDOMIZED COMPARISON OF ANTIPLATELET THERAPY AFTER THE PLACEMENT OF CORONARY ARTERY STENTS
A.K. Schomig (1996)
10.1056/NEJM199912233412601
Coronary Angioplasty with or without Stent Implantation for Acute Myocardial Infarction
Cindy Lee Grines (1999)
Polytetrafluoroethylenecovered stent for the treatment of narrowings in aortocoronary saphenous vein grafts
C Briguori (2000)
The U.S. multicenter, randomized, double blind study of the sirolimus-eluting stent in coronary lesions early (30 day) safety results (abstr)
J Moses (2001)
10.1016/S0002-9149(99)00874-7
Clinical and angiographic outcome after coronary arterial stenting with the carbostent.
David Antoniucci (2000)
Stent Placement Compared With Balloon Angioplasty for Small Coronary Arteries: In-Hospital and 6-Month Clinical and Angiographic Results
Hôpital Bon Secours (2001)
10.1016/S1062-1458(02)00556-1
Stent Placement to Prevent Restenosis After Angioplasty in Small Coronary Arteries
Serge Doucet (2001)
10.1161/01.CIR.91.7.1959
Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions.
Gary S. Mintz (1995)
10.1161/01.CIR.91.6.1676
Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance.
Antonio Colombo (1995)
10.1161/01.CIR.94.7.1519
Intracoronary stent implantation without ultrasound guidance and with replacement of conventional anticoagulation by antiplatelet therapy. 30-day clinical outcome of the French Multicenter Registry.
Gaetan J. Karrillon (1996)
A multicenter study examining the safety of a heparin-coated coronary stent in low risk patients treated with an antiplatelet therapy of aspirin alone (abstr)
M Leon (2001)
10.1016/S0735-1097(01)01491-7
Elective stenting of unprotected left main coronary artery stenosis: effect of debulking before stenting and intravascular ultrasound guidance.
S J Park (2001)
10.1161/01.CIR.101.21.2478
Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease.
Adnan Kastrati (2000)
10.1016/S0002-9149(96)00712-6
Effects of Palmaz-Schatz stents on angled coronary arteries.
Paxton Phillips (1997)
10.1161/01.CIR.89.3.1126
Major clinical events after coronary stenting. The multicenter registry of acute and elective Gianturco-Roubin stent placement. The Gianturco-Roubin Intracoronary Stent Investigator Group.
J M Sutton (1994)
10.1016/0735-1097(93)90827-N
Multicenter investigation of coronary stenting to treat acute or threatened closure after percutaneous transluminal coronary angioplasty: clinical and angiographic outcomes.
Barry S. George (1993)
10.1161/01.cir.93.3.412
Heparin-coated Palmaz-Schatz stents in human coronary arteries. Early outcome of the Benestent-II Pilot Study.
P. W. Serruys (1996)
The Venus trial: a multicenter registry of the Cordis BxVelocity stent (abstr)
JP Zidar (2000)
10.1161/01.CIR.102.12.1364
Randomized Comparison of GR-II Stent and Palmaz-Schatz Stent for Elective Treatment of Coronary Stenoses
Alexandra J Lansky (2000)
10.1016/S0002-9149(98)00408-1
Intravascular ultrasound findings in stenting of unprotected left main coronary artery stenosis.
Myeong-Ki Hong (1998)
10.1016/S0735-1097(02)80159-0
Sirolimus-eluting stents abolish neointimal hyperplasia in patients with in-stent restenosis: late angiographic and intravascular ultrasound results
Patrick W. Serruys (2002)
The Filterwire: first evaluation of a new protection catheter device for distal embolization in native coronary arteries in SVGs (abstr)
U Gerckens (2001)
10.1161/01.CIR.85.3.916
Intracoronary Stenting for Acute and Threatened Closure Complicating Percutaneous Transluminal Coronary Angioplasty
Gary S. Roubin (1992)
10.1016/S0735-1097(99)00303-4
Stented segment length as an independent predictor of restenosis.
Yoshio Kobayashi (1999)
Clinical safety and efficacy of the PercuSurge guidewire in the Saphenous vein graft Angioplasty Free of Emboli (SAFE) study (abstr)
E Grube (2000)
10.1056/NEJM199408253310802
A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators.
David L Fischman (1994)
10.1161/01.CIR.103.23.2816
[Intracoronary Stenting and Angiographic Results Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial].
Adnan Kastrati (2001)
10.1161/01.CIR.96.1.128
Coronary stenting after rotational atherectomy in calcified and complex lesions. Angiographic and clinical follow-up results.
Issam Moussa (1997)
10.1016/0735-1097(95)00448-3
Recanalization of Chronically Occluded Aortocoronary Saphenous Vein Bypass Grafts With Long-Term, Low Dose Direct Infusion of Urokinase (ROBUST): a serial trial.
Jul. Hartmann (1996)
10.1161/01.CIR.99.12.1548
Clinical and angiographic follow-Up after primary stenting in acute myocardial infarction: the Primary Angioplasty in Myocardial Infarction (PAMI) stent pilot trial.
Gregg W Stone (1999)
10.1016/S0140-6736(97)11128-X
Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)
Patrick W. Serruys (1998)
10.1016/S0735-1097(02)80088-2
Late (two-year) follow-up from the First-In-Man (FIM) experience after implantation of sirolimus-eluting stents
Jose Eduardo Sousaau (2002)
10.1002/(SICI)1097-0304(199607)38:3<236::AID-CCD2>3.0.CO;2-9
Oh no, even stenting is affected by calcium!
John McB. Hodgson (1996)
10.1161/01.CIR.102.25.3028
Emergency Polytetrafluoroethylene-Covered Stent Implantation to Treat Coronary Ruptures
Carlo Briguori (2000)
10.1161/01.CIR.103.13.1740
Relationship Between Neointimal Thickness and Shear Stress After Wallstent Implantation in Human Coronary Arteries
J J Wentzel (2001)
10.1016/S0735-1097(96)00452-4
Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: frequency, predictors and clinical outcome.
Issam Moussa (1997)
10.1002/(SICI)1522-726X(199901)46:1<113::AID-CCD28>3.0.CO;2-7
Obliteration of a coronary artery aneurysm with a PTFE-covered stent: endoluminal graft for coronary disease revisited.
Richard R Heuser (1999)
10.1056/NEJMoa012843
A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization.
M Morice (2002)
10.1016/S0735-1097(00)00570-2
Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Austrian Wiktor Stent Study Group and European Paragon Stent Investigators.
Mariann Gyöngyösi (2000)



This paper is referenced by
10.1007/s10554-017-1193-0
Conformability in everolimus-eluting bioresorbable scaffolds compared with metal platform coronary stents in long lesions
Jiang Ming Fam (2017)
Computational modeling of stented coronary arteries
Zuned Hajiali (2014)
10.1016/J.JIEC.2014.05.045
Mechanical behavior and in vivo properties of newly designed bare metal stent for enhanced flexibility
In-ho Bae (2015)
10.1533/9781845697488.3.341
Safety and efficacy issues in designing drug–device combination products: the case of drug eluting stents
Susie Willis (2010)
10.1023/B:CAIM.0000041950.84736.e6
Three-Dimensional Analysis of in vivo Coronary Stent – Coronary Artery Interactions
Robert Liao (2004)
FINITE ELEMENT ANALYSIS OF SHAPE MEMORY ALLOY NiTi STENT IN CORONARY ARTERY
Amatulraheem Al-abassi (2017)
- ray Analysis of Stents and Their Markers
P Periodica Polytechnica (2015)
10.1002/9781118402955.CH16
Structure Design of Vascular Stents
Yaling Liu (2013)
10.1177/0040517515590413
A biomechanically optimized knitted stent using a bio-inspired design approach
Charanpreet Singh (2016)
10.1002/cnm.2557
Finite element analysis of balloon-expandable coronary stent deployment: influence of angioplasty balloon configuration.
David Moral Martín (2013)
10.4244/EIJV7I1A19
In vivo assessment of optimal viewing angles from X-ray coronary angiography.
Shengxian Tu (2011)
Engineering aspects of stents design and their translation into clinical practice.
Giuseppe Sangiorgi (2007)
Use of coronary stents - material and biophysical conditions
Zbigniew Paszenda (2010)
10.1115/1.4032502
Evaluation of Different Meshing Techniques for the Case of a Stented Artery.
Azadeh Lotfi (2016)
10.1109/TUFFC.2020.2964322
Visibility of Bioresorbable Vascular Scaffold in Intravascular Ultrasound Imaging
Taewon Choi (2020)
Prospective registry evaluating safety and efficacy of cobalt-chromium stent implantation in patients with de novo coronary lesions.
Paweł E. Buszman (2007)
10.1002/jbm.a.35172
Effects of antibacterial nanostructured composite films on vascular stents: hemodynamic behaviors, microstructural characteristics, and biomechanical properties.
Han-Yi Cheng (2015)
10.4172/2329-6925.1000181
Research of Numerical Simulation of Biomechanics on In-stent-restenosis
Aike Qiao (2015)
Analysis of selected utility properties of biomaterials used in coronary stents
Witold Jurkiewicz (2013)
10.1007/978-1-4614-9434-8_18
Drug-Eluting Stents
Wahid Khan (2014)
10.1002/ccd.20606
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention-Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update the 2001 Guidelines for Percutaneous Coronary Intervention)
Sidney C. Smith (2006)
Improvement of haemodynamic stent strut configuration for Patent Ductus Arteriosus through computational modelling
Ishkrizat Taib (2016)
10.15406/atroa.2018.04.00081
A focused review on materials and generations of coronary stents
Hamidreza Shirzadfar (2018)
10.1002/jbm.b.33979
Evaluation of chemical stability of polymers of XIENCE everolimus-eluting coronary stents in vivo by pyrolysis-gas chromatography/mass spectrometry.
Marika Kamberi (2018)
Advances in helical stent design and fabrication thermal treatment and structural interaction studies of the simulated plaque-laden artery
Tré R Welch (2009)
Self-Assembled Monolayer-Based Surface Modification of Stainless Steel for Oriented Antibody Immobilization: Towards Improved Stent Biocompatibility
Pasquale Benvenuto (2015)
10.3311/PPME.7748
X-ray Analysis of Stents and Their Markers
Péter M. Nagy (2015)
10.1002/MAWE.201700241
Effect of thin SiO2 layers deposited by means of atomic layer deposition method on the mechanical and physical properties of stainless steel
Marcin Basiaga (2018)
10.1080/17434440.2019.1573142
Mechanical properties and performances of contemporary drug-eluting stent: focus on the metallic backbone
Ply Chichareon (2019)
10.1016/j.jmatprotec.2004.04.395
Effects of varying slotted tube (stent) geometry on its expansion behaviour using finite element method
S. N. David Chua (2004)
10.1177/0040517518797342
Comparative bending behaviors between fully covered and bare biodegradable polydioxanone biliary stents using a numerical approach
Yanhui Liu (2019)
10.1016/j.jcin.2010.07.016
A comparison of the conformability of everolimus-eluting bioresorbable vascular scaffolds to metal platform coronary stents.
Josep Gómez-Lara (2010)
See more
Semantic Scholar Logo Some data provided by SemanticScholar