Intravascular Ultrasound For Guidance And Optimization Of Percutaneous Coronary Intervention.

Dhruv Mahtta, Akram Y Elgendy, I. Elgendy, Ahmed N Mahmoud, J. Tobis, M. Mojadidi
Published 2018 · Medicine

Save to my Library
Download PDF
Analyze on Scholarcy Visualize in Litmaps
Share
Reduce the time it takes to create your bibliography by a factor of 10 by using the world’s favourite reference manager
Time to take this seriously.
Get Citationsy
Percutaneous coronary intervention (PCI) remains the mainstay management of symptomatic obstructive stable coronary artery disease (despite optimal medical treatment) and acute coronary syndrome. Intravascular ultrasound (IVUS) has emerged as an adjunct to angiography, permitting better assessment of the coronary lesion and stent apposition. Data from multiple studies have demonstrated improved clinical and procedural outcomes with IVUS-guided PCI. This review discusses the use of IVUS, with emphasis on technique, parameters, and applications during coronary interventions. In addition, the clinical outcomes data are highlighted with IVUS compared with conventional angiography-guided PCI.
This paper references
10.1161/01.CIR.49.4.703
Discrepancies Between Cineangiographic and Postmortem Findings in Patients with Coronary Artery Disease and Recent Myocardial Revascularization
C. Grondin (1974)
10.1001/JAMA.1978.03290190031023
Coronary angiogram interpretation. Interobserver variability.
J. E. Galbraith (1978)
10.1016/0002-9149(79)90248-0
Quantitation of coronary arterial narrowing at necropsy in sudden coronary death: analysis of 31 patients and comparison with 25 control subjects.
W. Roberts (1979)
10.1161/01.CIR.63.5.1056
Accuracy of Angiographic Determination of Left Main Coronary Arterial Narrowing: Angiographic‐Histologic Correlative Analysis in 28 Patients
J. Isner (1981)
10.1016/0167-5273(83)90033-5
Editorial note Observer variability in coronary angiography
L. Zir (1983)
10.1056/NEJM198403293101304
Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis?
C. White (1984)
10.1161/01.CIR.89.5.2026
Intracoronary ultrasound observations during stent implantation.
S. Nakamura (1994)
10.1161/01.CIR.92.8.2333
Our preoccupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease.
E. Topol (1995)
10.1161/01.CIR.96.9.2997
Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions.
R. Albiero (1997)
10.1053/EUHJ.1998.1012
Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)
P. D. de Jaegere (1998)
10.1161/01.CIR.100.3.256
Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions.
A. Abizaid (1999)
10.1161/01.CIR.102.20.2497
Ultrasound-Guided Strategy for Provisional Stenting With Focal Balloon Combination Catheter: Results From the Randomized Strategy for Intracoronary Ultrasound-Guided PTCA and Stenting (SIPS) Trial
A. Frey (2000)
10.1161/01.CIR.102.5.523
Final Results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) Study
P. Fitzgerald (2000)
10.1016/S0735-1097(01)01175-5
American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.
G. Mintz (2001)
10.1161/01.CIR.103.4.604
Intravascular ultrasound: novel pathophysiological insights and current clinical applications.
S. Nissen (2001)
10.1161/01.CIR.0000043240.87526.3F
Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery Stenoses: Final Results of a Randomized Comparison With Angiographic Guidance (TULIP Study)
P. Oemrawsingh (2003)
10.1161/01.CIR.0000047212.94399.7E
Intravascular Ultrasound–Guided Balloon Angioplasty Compared With Stent: Immediate and 6-Month Results of the Multicenter, Randomized Balloon Equivalent to Stent Study (BEST)
F. Schiele (2003)
10.1136/heart.89.9.1043
Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study
A. L. Gaster (2003)
10.1161/01.CIR.0000121327.67756.19
Contribution of Stent Underexpansion to Recurrence After Sirolimus-Eluting Stent Implantation for In-Stent Restenosis
K. Fujii (2004)
10.1161/01.CIR.0000146338.62813.E7
Correlations Between Fractional Flow Reserve and Intravascular Ultrasound in Patients With an Ambiguous Left Main Coronary Artery Stenosis
V. Jasti (2004)
10.1016/J.JACC.2004.01.044
Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.
S. Sonoda (2004)
10.1253/CIRCJ.68.1088
Novel technique using intravascular ultrasound-guided guidewire cross in coronary intervention for uncrossable chronic total occlusions.
Shigenori Ito (2004)
10.1002/ccd.10796
IVUS‐guided wiring technique: Promising approach for the chronic total occlusion
T. Matsubara (2004)
10.1016/J.JACC.2004.12.066
Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study.
K. Fujii (2005)
10.1007/BF01745150
Imaging artifacts in mechanically driven ultrasound catheters
H. Hoff (2005)
Intravascular ultrasound guided wiring for chronic total occlusions.
M. Ochiai (2006)
10.1016/J.AHJ.2006.10.036
Anatomical and physiologic assessments in patients with small coronary artery disease: final results of the Physiologic and Anatomical Evaluation Prior to and After Stent Implantation in Small Coronary Vessels (PHANTOM) trial.
M. Costa (2007)
10.1056/NEJMOA067193
Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.
G. Stone (2007)
10.1016/J.JACC.2007.04.032
Thrombosis and drug-eluting stents: an objective appraisal.
D. Holmes (2007)
10.1016/J.AHJ.2007.06.017
Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound. The multicenter, randomized trial results.
R. Gil (2007)
10.1093/eurheartj/ehn070
Ultrasound imaging techniques for the evaluation of cardiovascular therapies.
J. Kastelein (2008)
10.1016/S0140-6736(08)60922-8
Appropriate use of drug-eluting stents: balancing the reduction in restenosis with the concern of late thrombosis
A. Bavry (2008)
10.1056/NEJMoa0807611
Fractional flow reserve versus angiography for guiding percutaneous coronary intervention.
Pim A. L. Tonino (2009)
10.1161/CIRCINTERVENTIONS.108.778647
A Randomized Controlled Trial of Angiography Versus Intravascular Ultrasound-Directed Bare-Metal Coronary Stent Placement (The AVID Trial)
R. Russo (2009)
10.1161/CIRCINTERVENTIONS.108.799494
Impact of Intravascular Ultrasound Guidance on Long-Term Mortality in Stenting for Unprotected Left Main Coronary Artery Stenosis
S. Park (2009)
10.1002/ccd.22244
Long‐term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS
Jozef Jakabčin (2010)
10.1056/NEJMoa1002358
A prospective natural-history study of coronary atherosclerosis.
G. Stone (2011)
10.1161/CIR.0b013e31823ba622
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions.
G. Levine (2011)
10.1016/j.jcin.2011.03.013
Optimal intravascular ultrasound criteria and their accuracy for defining the functional significance of intermediate coronary stenoses of different locations.
B. Koo (2011)
10.1016/j.amjcard.2010.09.030
Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era.
H. Parise (2011)
10.4244/EIJV8I7A129
Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients.
Y. Zhang (2012)
10.3904/kjim.2012.27.1.30
Optimization of Stent Deployment by Intravascular Ultrasound
H. Yoon (2012)
10.1016/j.jacc.2012.08.990
Contemporary patterns of fractional flow reserve and intravascular ultrasound use among patients undergoing percutaneous coronary intervention in the United States: insights from the National Cardiovascular Data Registry.
Philip B. Dattilo (2012)
10.1161/CIRCULATIONAHA.113.001952
Comparison of Clinical Interpretation With Visual Assessment and Quantitative Coronary Angiography in Patients Undergoing Percutaneous Coronary Intervention in Contemporary Practice: The Assessing Angiography (A2) Project
Brahmajee K Nallamothu (2013)
10.1016/j.jcin.2012.11.009
Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses.
Jung-Sun Kim (2013)
10.1016/j.jacc.2012.12.012
FIRST: Fractional Flow Reserve and Intravascular Ultrasound Relationship Study.
R. Waksman (2013)
10.1016/j.ahj.2012.09.017
A prospective, randomized trial of intravascular-ultrasound guided compared to angiography guided stent implantation in complex coronary lesions: the AVIO trial.
A. Chieffo (2013)
10.1016/j.amjcard.2013.12.043
Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies.
Jung-Min Ahn (2014)
10.1161/CIRCULATIONAHA.113.003942
Relationship Between Intravascular Ultrasound Guidance and Clinical Outcomes After Drug-Eluting Stents: The Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Study
B. Witzenbichler (2014)
10.1016/j.jcin.2013.09.014
Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries.
J. M. de la Torre Hernandez (2014)
10.1016/j.jcin.2013.09.013
Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis.
Jae-Sik Jang (2014)
10.1016/j.jcin.2014.05.024
Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial.
José Mariani (2014)
10.1007/s40119-015-0051-1
The Impact of Fractional Flow Reserve on Revascularization
I. Elgendy (2015)
10.4244/EIJV10I12A245
Angiographic and clinical comparisons of intravascular ultrasound- versus angiography-guided drug-eluting stent implantation for patients with chronic total occlusion lesions: two-year results from a randomised AIR-CTO study.
N. Tian (2015)
10.1161/CIRCINTERVENTIONS.115.002592
Clinical Impact of Intravascular Ultrasound–Guided Chronic Total Occlusion Intervention With Zotarolimus-Eluting Versus Biolimus-Eluting Stent Implantation: Randomized Study
Byeong-Keuk Kim (2015)
10.1016/j.jacc.2015.04.017
Long-Term Safety of Drug-Eluting and Bare-Metal Stents: Evidence From a Comprehensive Network Meta-Analysis.
T. Palmerini (2015)
10.1186/s12872-015-0144-8
Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis
Y. Zhang (2015)
10.1007/s10198-015-0670-4
Understanding the economic impact of intravascular ultrasound (IVUS)
A. Alberti (2015)
10.15537/smj.2015.5.11251
Intravascular ultrasound-guided unprotected left main coronary artery stenting in the elderly
Q. Tan (2015)
10.1001/jama.2015.15454
Effect of Intravascular Ultrasound-Guided vs Angiography-Guided Everolimus-Eluting Stent Implantation: The IVUS-XPL Randomized Clinical Trial.
Sung-Jin Hong (2015)
10.1161/CIRCINTERVENTIONS.116.003700
Outcomes With Intravascular Ultrasound-Guided Stent Implantation: A Meta-Analysis of Randomized Trials in the Era of Drug-Eluting Stents
I. Elgendy (2016)
10.1016/j.jcin.2016.06.057
Utility of Intravascular Ultrasound in Percutaneous Revascularization of Chronic Total Occlusions: An Overview.
A. Galassi (2016)
10.1002/ccd.26679
Routine invasive versus selective invasive strategies for Non‐ST‐elevation acute coronary syndromes: An Updated meta‐analysis of randomized trials
I. Elgendy (2016)
10.1016/j.jacc.2016.05.042
Does the Baseline Coronary Lesion Length Impact Outcomes With IVUS-Guided Percutaneous Coronary Intervention?
I. Elgendy (2016)
10.1016/j.jcin.2016.07.021
Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients.
Dong-Ho Shin (2016)
10.1056/NEJMOA1610227
Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease.
G. Stone (2016)
10.1016/j.ijcard.2016.04.154
Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies.
A. Steinvil (2016)
10.1093/EURHEARTJ/EHW078
Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study.
Z. Ali (2016)
10.1016/S0140-6736(16)32052-9
Percutaneous coronary angioplasty versus coronary artery bypass grafting in treatment of unprotected left main stenosis (NOBLE): a prospective, randomised, open-label, non-inferiority trial
T. Mäkikallio (2016)
10.1016/j.jacc.2015.11.060
A Polylactide Bioresorbable Scaffold Eluting Everolimus for Treatment of Coronary Stenosis: 5-Year Follow-Up.
P. Serruys (2016)
10.1161/CIRCINTERVENTIONS.117.005286
Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents: A Meta-Analysis of Randomized Trials
A. Mahmoud (2017)
10.1016/S0140-6736(17)31957-8
Intravascular imaging in coronary artery disease
G. Mintz (2017)
10.1016/j.ahj.2016.10.008
Intravascular ultrasound–guided vs angiography‐guided drug‐eluting stent implantation in complex coronary lesions: Meta‐analysis of randomized trials
Chirag P Bavishi (2017)
10.1016/j.jacc.2017.09.1106
Effect of Technique on Outcomes Following Bioresorbable Vascular Scaffold Implantation: Analysis From the ABSORB Trials.
G. Stone (2017)
10.1002/ccd.26970
Percutaneous coronary intervention or coronary artery bypass grafting for unprotected left main coronary artery disease
A. Mahmoud (2017)
10.4244/EIJ-D-16-00247
Clinical outcomes of a real-world cohort following bioresorbable vascular scaffold implantation utilising an optimised implantation strategy.
A. Tanaka (2017)
10.1016/j.jcin.2018.01.254
Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States.
I. Elgendy (2018)
10.15212/CVIA.2017.0029
Intravascular Ultrasound‐Guided Percutaneous Coronary Intervention: An Updated Review
Dhruv Mahtta (2018)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar