New Insights On The Proximal Femur Biomechanics Using Digital Image Correlation.

Y. Katz, Z. Yosibash
Published 2020 · Medicine, Engineering

Cite This
Download PDF
Analyze on Scholarcy
Share
Finite element analyses (FEAs) of human femurs are mostly validated by ex-vivo experimental observations. Such validations were largely performed by comparing local strains at a small subset of points to the gold standard strain gauge (SG) measurements. A comprehensive full field validation of femoral FEAs including both strains and displacements using digital image correlation (DIC) full field measurements, especially at medial and lateral surfaces of the neck that experience the highest strains, provide new insights on femurs' mechanical behavior. Five cadaver femurs were loaded in stance position and monitored at the shaft and neck using two DIC systems simultaneously. DIC strains were compared to SG measurements at a limited number of locations so to corroborate DIC measurements by the gold standard technique. These were used to quantitatively assess the validity of FEA strains prediction especially at the neck where fracture usually occurs. Strains measured by DIC correspond well to the SG observations. An excellent agreement was observed between DIC and FEA predicted strains excluding the superior neck surface: FE=1.02×DIC-17,r2=0.977. At the superior neck however, strains were not well predicted by FEA models: Although the FEA predicted high strains at the 'saddle region', these were not observed experimentally. On the other hand, strain concentrations were measured by DIC at numerous vessel holes which were not represented by FE models. Since fractures usually initiate at the subcapital region in stance position ex-vivo experiments, where numerus vessel holes exist, these vessel holes may be required to be accounted for in future FE models so to allow a better estimation of the fracture load. Full field measurements are mandatory to allow a better validation of fracture load and location predictions which are of high clinical importance.
This paper references
10.1016/j.jbiomech.2011.03.024
Patient-specific finite element analysis of the human femur--a double-blinded biomechanical validation.
Nir Trabelsi (2011)
10.1016/j.jmbbm.2013.02.006
Experimental validation of finite element model for proximal composite femur using optical measurements.
L. Grassi (2013)
10.1118/1.1521940
Accuracy of CT-based thickness measurement of thin structures: modeling of limited spatial resolution in all three dimensions.
S. Prevrhal (2003)
10.1016/S1350-4533(01)00094-7
Prediction of fracture location in the proximal femur using finite element models.
J. Keyak (2001)
10.1016/j.clinbiomech.2018.06.012
Patient‐specific finite element analysis of femurs with cemented hip implants
Y. Katz (2018)
10.1007/BF01623175
Cross-calibration of liquid and solid QCT calibration standards: Corrections to the UCSF normative data
K. Faulkner (2005)
10.1016/j.jbiomech.2012.02.006
Prediction of the mechanical response of the femur with uncertain elastic properties.
Hagen Wille (2012)
10.1007/s10237-011-0322-2
The finite cell method for bone simulations: verification and validation
M. Ruess (2012)
10.1007/s10439-005-9020-5
Drug Delivery in the BME Curricula
M. Saltzman (2005)
10.1007/s10439-010-0196-y
Robust QCT/FEA Models of Proximal Femur Stiffness and Fracture Load During a Sideways Fall on the Hip
D. Dragomir-Daescu (2010)
10.1016/j.jbiomech.2013.06.035
Individual density-elasticity relationships improve accuracy of subject-specific finite element models of human femurs.
Sebastian Eberle (2013)
10.1016/J.JBIOMECH.2006.04.007
Artificial composite bone as a model of human trabecular bone: the implant-bone interface.
J. Grant (2007)
10.1016/j.jbiomech.2019.01.049
Scanner influence on the mechanical response of QCT-based finite element analysis of long bones.
Y. Katz (2019)
10.1016/j.jbiomech.2008.05.017
An accurate estimation of bone density improves the accuracy of subject-specific finite element models.
E. Schileo (2008)
10.1016/j.bone.2011.03.682
Male-female differences in the association between incident hip fracture and proximal femoral strength: a finite element analysis study.
J. Keyak (2011)
10.1115/1.4007173
Experimental validation of finite element models of intact and implanted composite hemipelvises using digital image correlation.
R. Ghosh (2012)
10.1007/s10439-017-1952-z
On the Failure Initiation in the Proximal Human Femur Under Simulated Sideways Fall
H. Bahaloo (2017)
10.1007/s11914-017-0346-3
Clinical Evaluation of Bone Strength and Fracture Risk
Chantal M. J. de Bakker (2017)
10.1016/j.jmbbm.2017.10.019
Development and in vitro validation of a simplified numerical model for the design of a biomimetic femoral stem.
Bruno Jetté (2018)
10.1002/jor.23540
Strain shielding inspired re‐design of proximal femoral stems for total hip arthroplasty
M. Cilla (2017)
10.1016/j.bone.2018.02.011
Pathological fracture risk assessment in patients with femoral metastases using CT-based finite element methods. A retrospective clinical study.
A. Sternheim (2018)
10.1115/1.4003129
Experimental validation of a finite element model of the proximal femur using digital image correlation and a composite bone model.
A. Dickinson (2011)
10.1302/0301-620X.47B3.560
THE DISTRIBUTION AND ANASTOMOSES OF ARTERIES SUPPLYING THE HEAD AND NECK OF THE FEMUR.
S. Sevitt (1965)
10.1016/j.medengphy.2012.09.007
Toward verified and validated FE simulations of a femur with a cemented hip prosthesis.
Zohar Yosibash (2013)
10.1243/09544119JEIM409
Cancellous bone screw purchase: A comparison of synthetic femurs, human femurs, and finite element analysis
R. Zdero (2008)
10.1016/j.jbiomech.2011.05.038
The human proximal femur behaves linearly elastic up to failure under physiological loading conditions.
M. Juszczyk (2011)
10.1115/1.4028415
Full-field strain measurement during mechanical testing of the human femur at physiologically relevant strain rates.
L. Grassi (2014)
10.1016/j.jbiomech.2016.02.032
How accurately can subject-specific finite element models predict strains and strength of human femora? Investigation using full-field measurements.
L. Grassi (2016)
10.1115/1.4025390
Development of an inertia-driven model of sideways fall for detailed study of femur fracture mechanics.
S. Gilchrist (2013)
10.1098/rsta.2010.0074
Predicting the yield of the proximal femur using high-order finite-element analysis with inhomogeneous orthotropic material properties
Z. Yosibash (2010)
10.1016/J.JBIOMECH.2007.06.017
Reliable simulations of the human proximal femur by high-order finite element analysis validated by experimental observations.
Z. Yosibash (2007)
10.1016/j.medengphy.2014.02.019
Development of a balanced experimental-computational approach to understanding the mechanics of proximal femur fractures.
B. Helgason (2014)
10.1007/s12018-015-9201-1
FEA to Measure Bone Strength: A Review
K. Engelke (2016)
10.1302/0301-620x.82b5.0820679
Anatomy of the medial femoral circumflex artery and its surgical implications.
E. Gautier (2000)
10.1016/j.jbiomech.2014.08.024
To what extent can linear finite element models of human femora predict failure under stance and fall loading configurations?
E. Schileo (2014)
10.1016/j.jbiomech.2013.05.021
Repeatability of digital image correlation for measurement of surface strains in composite long bones.
S. Väänänen (2013)
10.1016/j.bone.2014.09.022
Predicting the stiffness and strength of human femurs with real metastatic tumors.
Z. Yosibash (2014)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar