Online citations, reference lists, and bibliographies.
← Back to Search

A Quadrupole Ion Trap Mass Spectrometer For Dry Microparticle Analysis.

A. Özdemir, Jung-Lee Lin, M. Gülfen, Chun-Jen Hsiao, Chung-Hsuan Chen
Published 2019 · Materials Science, Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
In this work, we report a new design of a charge detection quadrupole ion trap mass spectrometer (QIT-MS) for the analysis of micro-sized dry inorganic and bioparticles including red blood cells (RBCs) and different sizes of MCF-7 breast cancer cells. The developed method is one of the fastest methods to measure the mass of micro-sized particles. This system allows the online analysis of various micro-sized particles up to 1 × 1017 Da. The calibration of the mass spectrometer has been done by using different sizes of polystyrene (PS) particles (2-15 μm). The measured masses of RBCs were around 1.8 × 1013 Da and MCF-7 cancer cells were between 1 × 1014 and 4 × 1014 Da. The calculated mass distribution profiles of the particles and cells were given as histogram profiles. The statistical data were summarized after Gaussian type fitting to the experimental histogram profiles. The new method gives very promising results for the analysis of particles and has very broad application.
This paper references
10.1039/B103933B
Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing.
S. Gawad (2001)
10.1021/AC020205L
Optical detection and charge-state analysis of MALDI-generated particles with molecular masses larger than 5 MDa.
Y. Cai (2002)
10.1063/1.1397295
Nondestructive high-resolution and absolute mass determination of single charged particles in a three-dimensional quadrupole trap
S. Schlemmer (2001)
10.1002/1615-9861(200101)1:1<66::AID-PROT66>3.0.CO;2-S
Single molecule detector for mass spectrometry with mass independent detection efficiency
D. Twerenbold (2001)
10.1002/MAS.20002
Optical detection methods for mass spectrometry of macroions.
Wen-Ping Peng (2004)
10.1021/acs.analchem.6b00918
Mass Measurement of Single Intact Nanoparticles in a Cylindrical Ion Trap.
N. Zhang (2016)
10.1021/JA00035A012
Electrospray mass spectrometry of poly(ethylene glycols) with molecular weights up to five million
Takashi Nohmi (1992)
10.1021/AC061597P
Design and characterization of a high-power laser-induced acoustic desorption probe coupled with a fourier transform ion cyclotron resonance mass spectrometer.
Ryan C. Shea (2007)
10.1088/0034-4885/59/3/002
Cryogenic particle detectors
D. Twerenbold (1996)
10.1021/AC0482054
Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry.
Ryan J Wenzel (2005)
10.1016/J.JASMS.2007.10.019
The analysis of polystyrene and polystyrene aggregates into the mega dalton mass range by cryodetection MALDI TOF MS
A. Aksenov (2008)
10.1002/1521-3773(20010202)40:3<541::AID-ANIE541>3.0.CO;2-K
Mass Spectrometry of an Intact Virus.
S. Fuerstenau (2001)
10.1038/nature05741
Weighing of biomolecules, single cells and single nanoparticles in fluid
T. Burg (2007)
10.1021/AC0602827
Characterization of laser-induced acoustic desorption coupled with a Fourier transform ion cyclotron resonance mass spectrometer.
Ryan C. Shea (2006)
10.1063/1.119667
Laser-induced acoustic desorption of electrons and ions
V. V. Golovlev (1997)
10.1002/ANIE.200503271
Laser-induced acoustic desorption mass spectrometry of single bioparticles.
Wen-Ping Peng (2006)
10.1016/j.bios.2011.04.010
A nanobeads amplified QCM immunosensor for the detection of avian influenza virus H5N1.
Dujuan Li (2011)
10.1116/1.1421572
Single cell detection with micromechanical oscillators
B. Ilić (2001)
10.1021/AC071207E
High-speed mass analysis of whole erythrocytes by charge-detection quadrupole ion trap mass spectrometry.
Zongxiu Nie (2007)
10.1021/acs.analchem.7b02937
ESI MS for Microsized Bioparticles.
A. Ozdemir (2017)
10.1016/J.IJMS.2007.10.012
Calibration of a frequency-scan quadrupole ion trap mass spectrometer for microparticle mass analysis
Zongxiu Nie (2008)
10.1038/nbt0901-833
Direct and sensitive detection of a human virus by rupture event scanning
M. Cooper (2001)
10.1021/AC051571I
Charge reduced electrospray size spectrometry of mega- and gigadalton complexes: whole viruses and virus fragments.
C. J. Hogan (2006)
10.1146/annurev-anchem-060908-155245
Ultrahigh-mass mass spectrometry of single biomolecules and bioparticles.
H. Chang (2009)
10.1021/acs.analchem.5b02324
Charge Detection Mass Spectrometry with Almost Perfect Charge Accuracy.
David Z. Keifer (2015)
10.1021/ACS.ANALCHEM.6B03789
Development of Visible-Wavelength MALDI Cell Mass Spectrometry for High-Efficiency Single-Cell Analysis.
C. Xiong (2016)
10.1002/RCM.1290091314
A Faraday cup detector for high‐mass ions in matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry
D. Imrie (1995)
10.1021/JA993740K
Electrospray time-of-flight mass spectrometry of the intact MS2 virus capsid
M. A. Tito (2000)
10.1016/S1387-3806(00)00181-0
Laser-induced acoustic desorption/chemical ionization in Fourier-transform ion cyclotron resonance mass spectrometry
J. Pérez (2000)
10.1039/c4lc00765d
On-demand weighing of single dry biological particles over a 5-order-of-magnitude dynamic range.
Bin-Da Chan (2014)
10.1016/S0168-1176(97)00209-7
Laser-induced acoustic desorption
V. Golovlev (1997)
10.1016/S0166-0934(01)00382-2
Detection of two orchid viruses using quartz crystal microbalance (QCM) immunosensors.
A. Eun (2002)
10.1126/SCIENCE.1095815
Reduction of Particulate Air Pollution Lowers the Risk of Heritable Mutations in Mice
C. Somers (2004)
10.1021/ac303565a
Ambient aerodynamic desorption/ionization method for microparticle mass measurement.
C. Xiong (2013)
10.1063/1.4861923
Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source.
Collin R. Howder (2014)
10.1016/j.bios.2012.10.038
Hydrogel based QCM aptasensor for detection of avian influenza virus.
R. Wang (2013)
10.1063/1.1667011
Single virus particle mass detection using microresonators with nanoscale thickness
A. Gupta (2004)
10.1021/JA046754L
Measuring masses of single bacterial whole cells with a quadrupole ion trap.
Wen-Ping Peng (2004)
10.1021/AC0206723
Ion trap mass spectrometry of fluorescently labeled nanoparticles.
Y. Cai (2003)
10.1021/ac7024392
Charge monitoring cell mass spectrometry.
Wen-Ping Peng (2008)
10.1016/0168-1176(95)04351-9
A charge detector for time-of-flight mass analysis of high mass ions produced by matrix-assisted laser desorption/ionization (MALDI)
U. Bahr (1996)



Semantic Scholar Logo Some data provided by SemanticScholar