Bone resorption around hip stems is a disturbing phenomenon, although its clinical significance and its eventual effects on replacement longevity are as yet uncertain. The relationship between implant flexibility and the extent of bone loss, frequently established in clinical patient series and animal experiments, does suggest that the changes in bone morphology are an effect of stress shielding and a subsequent adaptive remodeling process. This relationship was investigated using strain-adaptive bone-remodeling theory in combination with finite element models to simulate the bone remodeling process. The effects of stem material flexibility, bone flexibility, and bone reactivity on the process and its eventual outcome were studied. Stem flexibility was also related to proximal implant/bone interface stresses. The results sustain the hypothesis that the resorptive processes are an effect of bone adaptation to stress shielding. The effects of stem flexibility are confirmed by the simulation analysis. It was also established that individual differences in bone reactivity and mechanical bone quality (density and stiffness) may account for the individual variations found in patients and animal experiments. Flexible stems reduce stress shielding and bone resorption. However, they increase proximal interface stresses. Hence, the cure against bone resorption they represent may develop into increased loosening rates because of interface debonding and micromotion. The methods presented in this paper can be used to establish optimal stem-design characteristics or check the adequacy of designs in preclinical testing procedures.
This paper references
10.1302/0301-620X.69B1.3818732
Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.
C. Engh (1987)
Convergence and uniqueness of adaptive bone remodeling
Weinans (1989)
The influence of stem
J. D. Bobyn (1984)
Determinants of stress shielding -design vs. materials vs. interface. The Hip Society
J Galante
Quantification of bone loss of the proximal femur after total hip arthroplasty
G G. (1991)
The behavior of bone as a two - phase porous structure
D. R. Carter (1977)
10.1007/BF00041724
Bone remodeling I: theory of adaptive elasticity
S. Cowin (1976)
Validation of strain - adaptive bone remodelinganaly - sis to predict bone morphology around nonce - mented THA
R. Huiskes
Strain distribution changes in the proximal femur caused by metallic and flexible composite femoral components under torsional load
T. Otani
The influence of stem Clinical Orthopaedics and Related Research extent of porous coating on femoral bone resorption after primary cementless hip arthroolasty
C A Engh (1964)
Determinants of stress shielding - design vs. materials
J. Galante (1991)
size and extent of porous coating on femoral bone resorption after primary cementless hip arthroolasty
Huiskes (1988)
Ri ~ iI 11 vero , D . P . , and Galante , J . 0 . : A comparative studY ' : : ' l ' J of porous coatings in a weight - bearing total hitf : i ; l arthroplasty model
T. M. Turner
10.2106/00004623-198466020-00016
The influence of prosthetic stem stiffness and of a calcar collar on stresses in the proximal end of the femur with a cemented femoral component.
J. Lewis (1984)
Some fundamental aspects of humanjoint replacement
R. Huiskes (1980)
" ~ Convergence and uniqueness of adaptive bone remodeling
H. Weinans
10.3928/0147-7447-19890901-15
Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty.
R. Huiskes (1989)
10.1016/0021-9290(87)90020-0
The history of some fundamental concepts in bone biomechanics.
Hugo Roesler (1987)
0.: A comparative studY'::'l'J of porous coatings in a weight-bearing total hitf:i;l arthroplasty model
T. M. Turner (1986)
10.1016/S0883-5403(08)80074-5
Computer predictions of bone remodeling around porous-coated implants.
T. E. Orr (1990)
10.1016/0021-9290(87)90058-3
Trabecular bone density and loading history: regulation of connective tissue biology by mechanical energy.
D. Carter (1987)
The mechanical adaDtations of bone
J Currev
10.1097/00003086-199012000-00006
The various stress patterns of press-fit, ingrown, and cemented femoral stems.
R. Huiskes (1990)
0 . : Determinants of stress shielding - design vs . materials vs . interface
J. Galante
Adap - tive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty
R. Huiskes (1989)
10.1115/1.3138503
A computational method for stress analysis of adaptive elastic materials with a view toward applications in strain-induced bone remodeling.
R. T. Hart (1984)
10.1097/00003086-198912000-00015
Biomechanical and histologic investigation of cemented total hip arthroplasties. A study of autopsy-retrieved femurs after in vivo cycling.
W. Maloney (1989)
10.1016/0021-9290(89)90091-2
Relationships between loading history and femoral cancellous bone architecture.
D. Carter (1989)
A hypothesis concerning minimal bone density threshold levels as final stages of bone remodeling
H. Weinans
size and extent of porous coating on femoral bone resorption after primary cementless hip arthroolasty
A C. (1988)
10.1016/0021-9290(72)90003-6
The effects of geometric feedback in the development of osteoporosis.
R. B. Martin (1972)
Determinants of stress shielding - design vs. materials vs. interface. The Hip Society, 19th Open Scientific Meeting
R. T. Hart (1991)
10.1016/0021-9290(87)90030-3
Adaptive bone-remodeling theory applied to prosthetic-design analysis.
R. Huiskes (1987)
Porosity and specific surface of bone.
R. B. Martin (1984)
10.1002/jor.1100080507
An approach for time-dependent bone modeling and remodeling-application: a preliminary remodeling simulation.
G. Beaupré (1990)
Bone mineral density of the proximal femur after uncemented total hip arthroplasty
B. J. Kiratli (1991)
Validation of strainadaptive bone remodeling analysis to predict bone morphology around noncemented THA
R. Huiskes (1987)
10.2106/00004623-198668090-00013
A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.
T. Turner (1986)
10.1097/00003086-199012000-00022
The effect of stem stiffness on femoral bone resorption after canine porous-coated total hip arthroplasty.
J. Bobyn (1990)



This paper is referenced by
10.1016/j.jbiomech.2011.11.042
The influence of acetabular cup material on pelvis cortex surface strains, measured using digital image correlation.
A. S. Dickinson (2012)
10.1016/j.msec.2015.10.070
Ultrafine-grained porous titanium and porous titanium/magnesium composites fabricated by space holder-enabled severe plastic deformation.
Yuanshen Qi (2016)
10.3390/ijms15045426
Current Strategies to Improve the Bioactivity of PEEK
R. Ma (2014)
10.2174/1874325001004010169
Basic Science Considerations in Primary Total Hip Replacement Arthroplasty
Saqeb B. Mirza (2010)
10.12659/MSM.903768
Fabrication and Characterization of Carbon Fiber-Reinforced Nano-Hydroxyapatite/Polyamide46 Biocomposite for Bone Substitute
Zhennan Deng (2017)
En studie av bentäthetens korrelation med uppföljningstiden samt förekomst av reoperationer och stambyten i höfter reviderade med Wagnerstammar
Vidar Lindström (2011)
10.1002/jbm.a.32905
Bone bioelectricity: what have we learned in the past 160 years?
Brad M Isaacson (2010)
10.1016/j.clinbiomech.2018.01.006
Analysis of the elastic bending characteristics of cementless short hip stems considering the valgus alignment of the prosthetic stem
Alexander Jahnke (2018)
10.1177/112070000301300402
Bone mineral density 10 years after a Zweymüller uncemented stem prosthesis
T.M.J.S. Vervest (2003)
10.1115/DMD2019-3319
Risk-Based Analysis of Femoral Stem Considering Uncertainty in its Design Parameters
Godlove Wanki (2019)
10.1016/j.matdes.2020.108602
3D-printed ceramic triply periodic minimal surface structures for design of functionally graded bone implants
Sanjairaj Vijayavenkataraman (2020)
10.1108/mmms-06-2018-0109
Periprosthetic bone response to axial loading following TKR: Effect of polyethylene thickness and implant material – a finite element analysis study
Ravishanker B Baliga (2019)
10.3109/03008207.2013.813495
Effect of zinc ions on improving implant fixation in osteoporotic bone
Xudong Li (2013)
10.1016/j.msec.2016.04.078
Tribological behavior of a Ni-free Zr-based bulk metallic glass with potential for biomedical applications.
Nengbin Hua (2016)
10.1002/(SICI)1097-4636(19980605)40:3<475::AID-JBM19>3.0.CO;2-I
Comparison of human, primate, and canine femora: implications for biomaterials testing in total hip replacement.
T. Y. Kuo (1998)
10.1016/j.biomaterials.2010.08.102
Relationship between osseointegration and superelastic biomechanics in porous NiTi scaffolds.
Xiangmei Liu (2011)
Shape And Topology Optimization Design For Total Hip Joint Implant
Rajaa S. Abass (2019)
10.1016/j.msec.2016.05.113
Porous biomorphic silicon carbide ceramics coated with hydroxyapatite as prospective materials for bone implants.
O. Gryshkov (2016)
10.1016/j.biomaterials.2014.04.085
Polyetheretherketone/nano-fluorohydroxyapatite composite with antimicrobial activity and osseointegration properties.
L. Wang (2014)
10.1016/j.actbio.2016.09.012
Impact of ruthenium on mechanical properties, biological response and thermal processing of β-type Ti-Nb-Ru alloys.
Arne Biesiekierski (2017)
10.1016/J.SCRIPTAMAT.2016.12.038
Crystallographic texture control of beta-type Ti–15Mo–5Zr–3Al alloy by selective laser melting for the development of novel implants with a biocompatible low Young's modulus
Takuya Ishimoto (2017)
10.1016/j.actbio.2013.02.019
A Ni-free ZrCuFeAlAg bulk metallic glass with potential for biomedical applications.
Yan Liu (2013)
10.1682/JRRD.2012.11.0202
New method of fixation of in-bone implanted prosthesis.
Mark R. Pitkin (2013)
10.1007/BF01803940
Reprise des prothèses totales de hanche par implant fémoral personnalisé sans ciment recouvert d'hydroxyapatite dans les descellements sévères
X. Pascarel (2005)
10.15438/RR.V1I1.2
Joint Implant Surgery & Research Foundation Chagrin Falls, Ohio, USA FEA Analysis of Neck Sparing Versus Conventional Cementless Stem
Declan Brazil (2011)
Implant Surface Designs: An Overview
Reeta Jain (2016)
10.1016/j.bprint.2019.e00062
Photocrosslinking-based 3D printing of unsaturated polyesters from isosorbide: A new material for resorbable medical devices
Jan A Lammel-Lindemann (2020)
10.3390/ma13081992
Bone Regeneration in Critical-Sized Bone Defects Treated with Additively Manufactured Porous Metallic Biomaterials: The Effects of Inelastic Mechanical Properties
Marianne Koolen (2020)
10.1007/s11837-019-03879-w
The Effect of Oxygen Addition on Microstructure and Mechanical Properties of Various Beta-Titanium Alloys
Sonia Bartáková (2020)
10.1007/s42243-019-00294-y
Effects of solution treatment and cold rolling on structure and tensile properties of hot-rolled Ti–7.5Mo alloy
Yu-Ze Chen (2019)
10.1115/1.2796084
The predictive value of stress shielding for quantification of adaptive bone resorption around hip replacements.
J. Kuiper (1997)
10.2106/00004623-200209000-00020
Evaluation of a Femoral Stem with Reduced Stiffness: A Randomized Study with Use of Radiostereometry and Bone Densitometry
J. Kärrholm (2002)
See more
Semantic Scholar Logo Some data provided by SemanticScholar