Development Of An Inertia-driven Model Of Sideways Fall For Detailed Study Of Femur Fracture Mechanics.

S. Gilchrist, P. Guy, P. Cripton
Published 2013 · Geology, Medicine

Cite This
Download PDF
Analyze on Scholarcy
Share
A new method for laboratory testing of human proximal femora in conditions simulating a sideways fall was developed. Additionally, in order to analyze the strain state in future cadaveric tests, digital image correlation (DIC) was validated as a tool for strain field measurement on the bone of the femoral neck. A fall simulator which included models for the body mass, combined lateral femur and pelvis mass, pelvis stiffness, and trochanteric soft tissue was designed. The characteristics of each element were derived and developed based on human data from the literature. The simulator was verified by loading a state-of-the-art surrogate femur and comparing the resulting force-time trace to published, human volunteer experiments. To validate the DIC, 20 human proximal femora were prepared with a strain rosette and speckle paint pattern, and loaded to 50% of their predicted failure load at a low compression rate. Strain rosettes were taken as the gold standard, and minimum principal strains from the DIC and the rosettes were compared using descriptive statistics. The initial slope of the force-time curve obtained in the fall simulator matched published human volunteer data, with local peaks superimposed in the model due to internal vibrations of the spring used to model the pelvis stiffness. Global force magnitude and temporal characteristics were within 2% of published volunteer experiments. The DIC minimum principal strains were found to be accurate to 127±239 μɛ. These tools will allow more biofidelic laboratory simulation of falls to the side, and more detailed analysis of proximal femur failure mechanisms using human cadaver specimens.
This paper references
10.1016/0021-9290(75)90046-9
The effects of strain rate, reconstruction and mineral content on some mechanical properties of bovine bone.
J. Currey (1975)
10.1016/j.jbiomech.2011.06.015
Cervical spinal cord deformation during simulated head-first impact injuries.
A. Saari (2011)
10.1002/JBMR.5650110311
The effect of impact direction on the structural capacity of the proximal femur during falls
C. M. Ford (1996)
10.1016/S0021-9290(99)00202-X
Relationships between femoral fracture loads for two load configurations.
J. Keyak (2000)
10.1016/S8756-3282(01)00621-4
Mechanical strength of the proximal femur as predicted from geometric and densitometric bone properties at the lower limb versus the distal radius.
E. Lochmüller (2002)
10.1016/0021-9290(91)90305-7
Mechanical properties of trabecular bone. Dependency on strain rate.
F. Linde (1991)
10.2106/00004623-197052030-00005
Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis.
M. Singh (1970)
10.1115/1.2979867
The force attenuation provided by hip protectors depends on impact velocity, pelvic size, and soft tissue stiffness.
A. Laing (2008)
10.1089/JWH.2006.0245
Circumstances and consequences of falls in community-dwelling older women.
N. Nachreiner (2007)
10.1126/SCIENCE.996549
Bone compressive strength: the influence of density and strain rate.
D. Carter (1976)
10.1016/S0021-9290(02)00330-5
Bone mineral density correlates with fracture load in experimental side impacts of the pelvis.
D. P. Beason (2003)
10.1016/j.jbiomech.2009.10.042
Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia.
P. Sztefek (2010)
10.1016/j.bone.2008.07.244
Prediction of the fracture load of whole proximal femur specimens by topological analysis of the mineral distribution in DXA-scan images.
H. Böhm (2008)
10.1299/JBSE.4.336
Relationship between the load-displacement curve and deformation distribution in porcine mandibular periodontium
Y. Morita (2009)
10.1016/j.jbiomech.2010.03.025
Characterizing the effective stiffness of the pelvis during sideways falls on the hip.
A. Laing (2010)
10.1115/1.2838032
The effect of strain rate on the mechanical properties of human cortical bone.
U. Hansen (2008)
10.1007/BF02368492
The response of compact bone in tension at various strain rates
R. Crowninshield (2006)
Proximal femur strength: Correlation of the rate of loading and bone mineral density
T. G. Weber (1992)
10.1002/jbmr.315
Body mass index and physical activity in relation to the incidence of hip fracture in postmenopausal women
Miranda E G Armstrong (2011)
10.1001/JAMA.1994.03510260060029
Fall severity and bone mineral density as risk factors for hip fracture in ambulatory elderly.
S. Greenspan (1994)
10.1016/j.jbiomech.2009.05.001
During sideways falls proximal femur fractures initiate in the superolateral cortex: evidence from high-speed video of simulated fractures.
P. D. de Bakker (2009)
10.1115/1.4003129
Experimental validation of a finite element model of the proximal femur using digital image correlation and a composite bone model.
A. Dickinson (2011)
10.1002/JOR.20172
Effect of compliant flooring on impact force during falls on the hip
A. Laing (2006)
10.1007/s00198-008-0675-2
Cortical and trabecular bone in the femoral neck both contribute to proximal femur failure load prediction
S. Manske (2008)
10.1007/BF02323147
Instrumented tensile-impact tests of bone
S. Saha (1974)
10.1016/j.jbiomech.2008.07.025
Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.
Peter Zioupos (2008)
10.1016/J.JBIOMECH.2007.03.015
In vitro replication of spontaneous fractures of the proximal human femur.
L. Cristofolini (2007)
10.1359/JBMR.050520
Identification of High‐Risk Individuals for Hip Fracture: A 14‐Year Prospective Study
N. Nguyen (2005)
10.1359/jbmr.081201
Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
E. Orwoll (2009)
10.1002/JOR.1100130621
Force attenuation in trochanteric soft tissues during impact from a fall
S. Robinovitch (1995)
10.1007/BF02684190
Distribution of contact force during impact to the hip
S. Robinovitch (2007)
10.1016/S0021-9290(03)00257-4
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue.
Harun H. Bayraktar (2004)
10.1359/jbmr.081246
Risk Factors for Severity and Type of the Hip Fracture
J. Cauley (2009)
10.1007/s001980050197
Survival after Hip Fracture: Short- and Long-Term Excess Mortality According to Age and Gender
L. Forsén (1999)
10.1016/J.MEDENGPHY.2004.05.002
Comparison of compact bone failure under two different loading rates: experimental and modelling approaches.
M. Pithioux (2004)
10.1007/s11657-011-0064-x
Femoral neck bone mineral density and 10-year absolute fracture risk in a national representative sample of Bulgarian women aged 50 years and older
A. Borissova (2011)
10.1093/AGEING/AFL186
Are hip protectors correctly positioned in use?
R. Minns (2007)
10.2106/00004623-199072050-00008
The use of quantitative computed tomography to estimate risk of fracture of the hip from falls.
J. C. Lotz (1990)
10.1016/J.JBIOMECH.2007.01.019
Reducing hip fracture risk during sideways falls: evidence in young adults of the protective effects of impact to the hands and stepping.
F. Feldman (2007)
10.1016/0021-9290(95)00134-4
Hip impact velocities and body configurations for voluntary falls from standing height.
A. J. van den Kroonenberg (1996)
10.1001/ARCHINTE.164.10.1108
Bone Mineral Density Thresholds for Pharmacological Intervention to Prevent Fractures
E. Siris (2004)
10.1186/1471-2474-6-11
Abdominal fat and hip fracture risk in the elderly: The Dubbo Osteoporosis Epidemiology Study
N. Nguyen (2005)
10.1152/JAPPL.1966.21.4.1231
Dynamic response of bone and muscle tissue.
J. Mcelhaney (1966)
10.1007/BF00310169
Effects of loading rate on strength of the proximal femur
A. Courtney (2004)
10.1002/jbmr.235
BMI and Fracture Risk in Older Men: The Osteoporotic Fractures in Men Study (MrOS)
C. Nielson (2011)
10.1115/1.2794186
Dynamic models for sideways falls from standing height.
A. J. van den Kroonenberg (1995)
10.1016/j.jbiomech.2008.07.001
Effects of trochanteric soft tissue thickness and hip impact velocity on hip fracture in sideways fall through 3D finite element simulations.
S. Majumder (2008)
10.1007/s001980170116
Economic Implications of Hip Fracture: Health Service Use, Institutional Care and Cost in Canada
M. Wiktorowicz (2001)
10.1007/s11999-008-0473-3
Proximal Femoral Anatomy in the Normal Human Population
Paul A Toogood (2009)
10.1002/jbmr.1856
Use of DXA‐based finite element analysis of the proximal femur in a longitudinal study of hip fracture
K. Naylor (2013)
10.1007/BF02508641
Impact direction from a fall influences the failure load of the proximal femur as much as age-related bone loss
T. Pinilla (2006)
10.1115/1.2895414
Prediction of femoral impact forces in falls on the hip.
S. Robinovitch (1991)
10.1243/0309324971513337
In vitro measured strains in the loaded femur: Quantification of experimental error
L. Cristofolini (1997)
10.4271/973344
THE DYNAMIC RESPONSES OF THE CERVICAL SPINE: BUCKLING, END CONDITIONS, AND TOLERANCE IN COMPRESSIVE IMPACTS
R. Nightingale (1997)
10.1016/0021-9290(78)90057-X
Compressive strength of mandibular bone as a function of microstructure and strain rate.
D. Robertson (1978)
10.1007/s00198-009-1045-4
Hip protectors: recommendations for biomechanical testing—an international consensus statement (part I)
S. Robinovitch (2009)
10.1016/j.annepidem.2008.07.007
The association of hip circumference with incident hip fracture in a cohort of postmenopausal women: the Iowa Women's Health Study.
E. Parker (2008)
10.1359/jbmr.2003.18.11.1947
BMD at Multiple Sites and Risk of Fracture of Multiple Types: Long‐Term Results From the Study of Osteoporotic Fractures
K. Stone (2003)
10.1007/s00198-003-1489-x
Bone quality: where do we go from here?
M. Bouxsein (2003)
10.1359/jbmr.070309
Contribution of Trochanteric Soft Tissues to Fall Force Estimates, the Factor of Risk, and Prediction of Hip Fracture Risk*
M. Bouxsein (2007)
10.1016/J.JBIOMECH.2005.10.027
Comparison of micro-level and continuum-level voxel models of the proximal femur.
E. Verhulp (2006)
10.1210/jc.2008-1640
Trochanteric soft tissue thickness and hip fracture in older men.
C. Nielson (2009)
10.1016/j.bone.2009.10.020
Comparison of hip fracture risk prediction by femoral aBMD to experimentally measured factor of risk.
B. Roberts (2010)
10.1046/j.1532-5415.2003.51110.x
Estimating Hip Fracture Morbidity, Mortality and Costs
R. Braithwaite (2003)



This paper is referenced by
Characterisation of trabecular bone behaviour under impact
B. Rosli (2019)
10.1016/j.jmbbm.2016.08.016
Contribution of fluid in bone extravascular matrix to strain-rate dependent stiffening of bone tissue - A poroelastic study.
Solenn Le Pense (2017)
10.5277/ABB-00785-2016-04
Digital image correlation techniques for strain measurement in a variety of biomechanical test models.
Sarah E Hensley (2017)
10.14288/1.0319083
Quantifying the response of vertebral bodies to compressive loading using digital image correlation
Hannah M Gustafson (2016)
10.1016/j.medengphy.2016.08.010
Morphology based anisotropic finite element models of the proximal femur validated with experimental data.
W. Enns-Bray (2016)
10.14288/1.0166885
Comparison of proximal femur deformations, failures and fractures in quasi-static and inertially-driven simulations of a sideways fall from standing : an experimental study utilizing novel fall simulation, digital image correlation, and development of digital volume correlation techniques
S. Gilchrist (2014)
10.1016/B978-0-12-803802-4.00005-6
Digital image correlation for strain analysis of whole bones and implants
K. E. Rankin (2017)
10.1115/1.4032799
Comparison of Strain Rosettes and Digital Image Correlation for Measuring Vertebral Body Strain.
H. Gustafson (2016)
10.1371/journal.pone.0201096
A novel sideways fall simulator to study hip fractures ex vivo
I. Fleps (2018)
10.1097/BRS.0000000000002156
Damage Identification on Vertebral Bodies During Compressive Loading Using Digital Image Correlation
H. Gustafson (2017)
10.1007/s10439-017-1928-z
The Influence of Body Mass Index, Sex, & Muscle Activation on Pressure Distribution During Lateral Falls on the Hip
S. Pretty (2017)
10.1016/j.jbiomech.2014.06.040
Proximal femur elastic behaviour is the same in impact and constant displacement rate fall simulation.
S. Gilchrist (2014)
Development of a Porcine FE Model for the Investigation of Vertebral Laminae Strains Resulting From Facet Tropism
Colin Bright (2017)
10.1177/0954411915591617
Full-field in vitro measurements and in silico predictions of strain shielding in the implanted femur after total hip arthroplasty
S. Chanda (2015)
10.1115/1.4047077
Leg Joint Stiffness Affects Dynamics of Backward Falling From Standing Height: A Simulation Work.
Mu Qiao (2020)
10.1016/j.jmbbm.2017.10.033
Material mapping strategy to improve the predicted response of the proximal femur to a sideways fall impact.
W. Enns-Bray (2018)
10.13140/RG.2.2.26512.00000
Femoral Strength Prediction using Finite Element Models : Validation of models based on CT and reconstructed DXA images against full-field strain measurements
L. Grassi (2016)
10.1080/23335432.2015.1117395
The use of digital image correlation in the biomechanical area: a review
M. Palanca (2016)
10.1177/0954411920951033
Comparison of femur strain under different loading scenarios: Experimental testing.
Ievgen Levadnyi (2020)
10.1016/j.jbiomech.2015.02.022
Strain distribution in the proximal Human femur during in vitro simulated sideways fall.
L. Zani (2015)
10.1016/j.jmbbm.2017.10.019
Development and in vitro validation of a simplified numerical model for the design of a biomimetic femoral stem.
Bruno Jetté (2018)
10.1016/j.jmbbm.2019.103593
Comparing the fracture limits of the proximal femur under impact and quasi-static conditions in simulation of a sideways fall.
F. Jazinizadeh (2020)
10.1002/jor.23445
Fully porous 3D printed titanium femoral stem to reduce stress‐shielding following total hip arthroplasty
Sajad Arabnejad (2017)
10.1088/1757-899x/511/1/012018
Measurement Affecting Errors in Digital Image Correlation
V. Titkov (2019)
10.1088/1757-899x/670/1/012026
A review of hip fracture analysis subjected to impact loading
A. A. M. Zuki (2019)
Fully Porous 3 D Printed Titanium Femoral Stem to Reduce Stress-Shielding Following Total Hip Arthroplasty
Sajad Arabnejad (2016)
10.1016/j.medengphy.2016.11.007
Pharmaceutical aerosols deposition patterns from a Dry Powder Inhaler: Euler Lagrangian prediction and validation.
Ravishekar Ravi Kannan (2017)
10.1016/j.jbiomech.2016.02.032
How accurately can subject-specific finite element models predict strains and strength of human femora? Investigation using full-field measurements.
L. Grassi (2016)
10.1016/j.jbiomech.2014.11.042
Comparison of explicit finite element and mechanical simulation of the proximal femur during dynamic drop-tower testing.
O. Ariza (2015)
10.1115/1.4028415
Full-field strain measurement during mechanical testing of the human femur at physiologically relevant strain rates.
L. Grassi (2014)
Développement d'une tige fémorale biomimétique intégrant une structure cellulaire poreuse
Bruno Jetté (2018)
10.1038/bonekey.2016.86
Prophylactic augmentation of the osteoporotic proximal femur-mission impossible?
P. Varga (2016)
See more
Semantic Scholar Logo Some data provided by SemanticScholar