Online citations, reference lists, and bibliographies.
← Back to Search

Accuracy Of Lung Dose Calculations For Large-field Irradiation With 6-MV X Rays.

E. Elkhatib, J. Battista
Published 1986 · Medicine

Save to my Library
Download PDF
Analyze on Scholarcy
Share
In large-field irradiations of the upper half-body, there is a potential for severe respiratory complications. The incidence of severe radiation damage to lung can be reduced by limiting the lung dose and the volume of lung irradiated. It is necessary to have an accurate method of calculating the dose actually delivered to lung, and this work deals with such calculations and measurements in large (half-body) fields of 6-MV x rays. The results of various lung dose calculations by the Batho, the modified Batho (Lulu and Bjärngard), the simple scaled tissue-maximum ratio and the detailed equivalent tissue-air ratio methods are compared with doses measured in phantoms representing the mediastinum and adjacent lungs.



This paper is referenced by
10.1118/1.599004
The impact of electron transport on the accuracy of computed dose.
M. Arnfield (2000)
Fabrication of low cost in-house slab homogeneous and heterogeneous phantoms for lung radiation treatment
S. Senthilkumar (2011)
10.1016/S1507-1367(06)71057-4
Experimental and Monte Carlo evaluation of Eclipse treatment planning system for lung dose calculations
A. Mesbahi (2006)
10.37206/86
Tissue Inhomogeneity Corrections for Megavoltage Photon Beams
N. Papanikolaou (2004)
10.1007/s11604-005-1493-5
Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
A. Farajollahi (2005)
Accuracy in radiotherapy dosimetry
M. Allahverdi (1998)
10.1088/0031-9155/35/2/003
An equivalent shape approximation for photon doses in lung
J. E. O'connor (1990)
10.1016/S1507-1367(04)71030-5
Experimental evaluation of ALFARD treatment planning system for 6 MV photon irradiation: a lung case study
A. Mesbahi (2004)
10.1118/1.3285042
The effects of dose calculation resolution on dose accuracy for radiation therapy treatments of the lung. Part I. A Monte Carlo model of the lung.
Kerry Babcock (2010)
10.1118/1.1357223
Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models.
F. du Plessis (2001)
Comparison of two planning methods for heterogeneity correction in planning total body irradiation
Emily Flower (2005)
10.22215/etd/2008-06208
Dose errors in the treatment planning process of cancer radiotherapy
W. Myint (2008)
10.1088/0031-9155/39/1/002
A translating-bed technique for total-body irradiation.
L. Gerig (1994)
10.1016/0360-3016(95)02384-4
Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6 MV and 18 MV photons.
P. White (1996)
10.22086/JBPE.V0I0.408
Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements
N. Singh (2018)
10.1016/0360-3016(90)90330-M
Physical aspects of external beam radiotherapy for the treatment of malignant pleural mesothelioma.
M. Soubra (1990)
The effects of anatomic resolution, respiratory variations and dose calculation methods on lung dosimetry
Kerry Babcock (2010)
10.1118/1.2750972
Comparison of dose calculation algorithms in slab phantoms with cortical bone equivalent heterogeneities.
P. Carrasco (2007)
Photon Dose Calculations in a Fluence-Based Treatment Planning System: Data Processing, Implementation and Validation
L. Weber (2003)
10.1016/S0360-3016(99)00154-6
Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation.
J. Hanley (1999)
10.1016/S0360-3016(98)90022-0
Benchmark measurements for lung dose corrections for X-ray beams.
R. Rice (1988)
10.1118/1.1601331
Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs.
J. Chow (2003)
10.1118/1.1788932
Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium.
P. Carrasco (2004)
Semantic Scholar Logo Some data provided by SemanticScholar