THE EFFECT OF COMPUTED TOMOGRAPHY CURRENT REDUCTION ON PROXIMAL FEMUR SUBJECT-SPECIFIC FINITE ELEMENT MODELS

C. Falcinelli, E. Schileo, F. Baruffaldi, L. Cristofolini, F. Taddei
Published 2017 · Mathematics

Cite This
Download PDF
Analyze on Scholarcy
Share
Many studies have addressed the modulation of computed tomography (CT) parameters, and particularly of tube current, to obtain a good compromise between the X-ray dose to the patient and the image quality for diagnostic applications. This study aimed at evaluating the influence of dose reduction by means of tube current reduction on the CT-based subject-specific finite element (FE) modeling. To this aim, CT scans at stepwise reduced values of tube current from 180mAs to 80mAs were performed on: (i) a densitometric phantom, to quantify the changes in the calibration equation; (ii) a fresh-frozen, water submersed, human cadaver femur, to quantify changes in geometry reconstruction and material mapping from CT, as well as strain prediction accuracy, based on the in vitro strain measurements available; (iii) a fresh-frozen human cadaver thigh with soft tissues attached, to quantify FE results changes in conditions similar to those found in vivo. The results showed that the tube current reduction does not affect the 3D modeling and the femur FE analysis. Our pilot study highlights the possibility of performing CT scans with reduced dose to generate biomechanical models, although a confirmation by performing larger studies with clinical CT data is needed.
This paper references
10.2214/ajr.164.3.7863879
CT of the chest: minimal tube current required for good image quality with the least radiation dose.
J. Mayo (1995)
10.1259/BJR.74.878.740157
The effect of decreasing mAs on image quality and patient dose in sinus CT.
S. Sohaib (2001)
10.1016/J.JBIOMECH.2005.07.018
Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy.
F. Taddei (2006)
10.1016/J.JBIOMECH.2007.02.010
Subject-specific finite element models can accurately predict strain levels in long bones.
E. Schileo (2007)
10.1148/RADIOL.2322031304
Comparison of Z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis.
M. Kalra (2004)
10.1007/s00330-001-1255-4
Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)
H. Greess (2001)
10.1007/s002470050692
Radiation dose reduction in paediatric cranial CT
C. Chan (1999)
10.1118/1.596899
A phantom for standardization and quality control in spinal bone mineral measurements by QCT and DXA: design considerations and specifications.
W. Kalender (1992)
10.1016/J.MEDENGPHY.2007.05.006
A modified method for assigning material properties to FE models of bones.
B. Helgason (2008)
10.1016/J.MEDENGPHY.2003.11.008
Specialised CT scan protocols for 3-D pre-operative planning of total hip replacement.
R. Lattanzi (2004)
10.1016/S0021-9290(03)00071-X
Trabecular bone modulus-density relationships depend on anatomic site.
E. Morgan (2003)
10.1016/J.CRAD.2004.08.011
Effect of reduction in tube current on reader confidence in paediatric computed tomography.
R. Shah (2005)
10.1016/S0021-9290(01)00040-9
Hip contact forces and gait patterns from routine activities.
G. Bergmann (2001)
10.1359/jbmr.081201
Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
E. Orwoll (2009)
10.1243/09544119JEIM497
Strain distribution in the proximal human femoral metaphysis
L. Cristofolini (2009)
10.1148/RADIOL.2333031150
Techniques and applications of automatic tube current modulation for CT.
M. Kalra (2004)
10.1016/j.jbiomech.2009.11.022
Structural behaviour and strain distribution of the long bones of the human lower limbs.
L. Cristofolini (2010)
10.1016/j.bone.2011.03.682
Male-female differences in the association between incident hip fracture and proximal femoral strength: a finite element analysis study.
J. Keyak (2011)
10.1016/j.medengphy.2010.09.014
Evaluation of the generality and accuracy of a new mesh morphing procedure for the human femur.
L. Grassi (2011)
10.1016/J.JBIOMECH.2007.09.009
Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro.
E. Schileo (2008)
10.1016/j.ejmp.2008.01.012
Technical approaches to the optimisation of CT.
W. Kalender (2008)
10.1016/J.JBIOMECH.2006.08.003
Prediction of strength and strain of the proximal femur by a CT-based finite element method.
M. Bessho (2007)
10.2214/AJR.04.1513
Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis.
S. Rizzo (2006)
10.1002/jbmr.347
Association of hip strength estimates by finite‐element analysis with fractures in women and men
S. Amin (2011)
10.1016/S0021-9290(12)70542-0
FE-BASED STRENGTH ESTIMATION FOR THE PREDICTION OF FEMORAL NECK FRACTURE
Cristina Falcinelli (2012)
10.2214/AJR.183.3.1830809
Low-dose chest CT: optimizing radiation protection for patients.
Xiaohua Zhu (2004)
10.2214/AJR.179.5.1791101
Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality.
M. Kalra (2002)
10.1016/j.bone.2012.06.026
Cortical bone finite element models in the estimation of experimentally measured failure loads in the proximal femur.
Janne E. M. Koivumäki (2012)
10.1148/RADIOL.2362041565
Metallic prosthesis: technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients.
Tejas Dalal (2005)
10.1148/RADIOL.2303021726
Strategies for CT radiation dose optimization.
M. Kalra (2004)
10.1016/S0021-9290(03)00257-4
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue.
Harun H. Bayraktar (2004)
10.1016/S0021-9290(08)70201-X
PREDICTION OF FAILURE LOAD AND LOCATION ON PROXIMAL FEMUR UNDER A SINGLE STANCE LOADING CONDITION
Andrea Malandrino (2008)
10.1016/j.jbiomech.2008.05.017
An accurate estimation of bone density improves the accuracy of subject-specific finite element models.
E. Schileo (2008)
10.1016/J.MEDENGPHY.2006.10.014
The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements.
F. Taddei (2007)
10.1016/S1350-4533(03)00018-3
CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning.
M. Viceconti (2003)
10.2214/AJR.179.2.1790461
Standard-dose and 50%-reduced-dose chest CT: comparing the effect on image quality.
S. Prasad (2002)
10.1007/s00330-005-2720-2
Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT
J. Gurung (2005)



This paper is referenced by
Semantic Scholar Logo Some data provided by SemanticScholar